DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
PLM-Aging Inspection6/15/20206/15/20206/15/2020 PASS
DetailsMatt Wrobel
permit expired
DOC - Permit Expired6/15/20206/15/20206/15/2020PPASS
DetailsMatt Wrobel
PLM-Aging Inspection3/16/20203/16/20203/16/2020 PART
DetailsMatt Wrobel
no calls permit will expire next aging
PLM-Aging Inspection12/16/201912/16/201912/17/2019 FAIL
DetailsMatt Wrobel
left msg with contractor to schedule inspection
PLM-Aging Inspection9/16/20199/16/20199/16/2019 PART
DetailsMatt Wrobel
no calls
Final1/18/20191/18/20191/18/2019PNH
DetailsMatt Wrobel
Please call Caleb prior to inspection so she can meet you at ###-#### Inspection requested via web by Margie Rowe
Final1/8/20191/8/20191/8/2019PFAIL
DetailsMatt Wrobel
Please call Kayla Hall prior to inspection ###-#### Inspection requested via web by Margie Rowe
water heater vent b vent portion needs extended below drywall and drywall repaired need 1 inch shield in attic space ane 1 inch clearance from drywall penetraition
t & p cannot terminate in drain pan must be run to floor
existing t & p line has no approved fittings so new approved material will need to be used to run down and terminate with water alarm as t & p cannot easilly be routed to exterior
Final1/4/20191/7/20191/7/2019ANH
DetailsMatt Wrobel
Inspection requested via web by Margie Rowe