Final | 3/9/2020 | 3/10/2020 | 3/10/2020 | A | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Klaas
|
Card not on site to sign | 3/10/2020 | 3/10/2020 | 3/10/2020 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Klaas
|
Final | 3/8/2020 | 3/9/2020 | 3/9/2020 | A | FAIL |
Matt Wrobel
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Klaas 1. publicly accessable lavatories require tempering valves 2. double check needs to be tested and certified
|
Final | 3/3/2020 | 3/4/2020 | 3/4/2020 | A | NH |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Klaas-No access, left notice.
|
Plumbing Rough-in | 2/3/2020 | 2/3/2020 | 2/3/2020 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Klaas
|
Plumbing Rough-in | 1/31/2020 | 1/31/2020 | 1/31/2020 | P | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Klaas-Need to use a mission coupling from cast iron to abs in groundwork connection.
|
Plumbing Rough-in | 1/30/2020 | 1/30/2020 | 1/30/2020 | P | FAIL |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Klaas. Heat tape isn't an approved assembly for freeze protection in an attic. Pipe must be attached to the joist, visqueen under the pipe, insulation bats over the pipe attached to the joists.
|
Plumbing Rough-in | 1/29/2020 | 1/30/2020 | 1/30/2020 | A | FAIL |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Klaas 1. Cannot run the water lines in the cold attic without freeze protection assembly. 2. An expansion tank will be required on trim. 3. Verify ADA WC r-in.
|