Permit Information
Permit NumberBLD18-00094
StatusIssued
Name MAROSVARI MARLA
Site Address 2003 S CLEVELAND ST
Project Name 
Customer Number 
ePlanReviewNo
Description
PLAN MODIFICATION II - 10-24-18 - Rebuilding front and rear deck as per provided engineering and plans. PLAN MODIFICATION- 9-24-18 - (Discovered termite and structural concerns; removing bay window in Kitchen, replacing from foundation up; removing wall between Kitchen and Bathroom due to termite damage; removing and replacing interior bearing in crawl space between Kitchen and Living Room; adding additional beams and purlins to repair Kitchen ceiling. See Engineering provided for the modifications.***BJM***) Permit to remove interior bearing wall between Kitchen and Living Room and replace with new beam, replace structure supporting ceiling between Kitchen and Dining Room with new beam, install new Kitchen, replace one Kitchen window with new window to fit into existing opening. Smoke detectors and carbon monoxide alarms to be updated as needed/required. Separate electrical, plumbing and mechanical permits are required. All work to be done as per plans, engineering, notes, review notes and local codes. ***BJM***
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Change Expiration Date Only  7/15/2020 DONE
DetailsJason Blais
First 180 day extension for an issued permit approved.
BLD-Aging Inspection1/3/20201/3/20201/3/2020 PASS
DetailsJim Storey
wip
BLD-Aging Inspection8/22/20198/22/20198/22/2019 PASS
DetailsJim Storey
wip
BLD-Aging Inspection8/21/20198/21/20198/22/2019 PASS
DetailsJim Storey
wip
BLD-Other6/28/20197/1/20197/1/2019APART
DetailsJim Storey
Marla- inspection for interior Phone #: ###-#### inside ok pending outside roofs
BLD-Aging Inspection4/9/20194/9/20194/9/2019 PASS
DetailsJim Storey
BLD-Energy code compliance11/26/201811/26/201811/26/2018PPASS
DetailsBrandon Shaw
Marla (or alt. contact is Ella ###-####) Phone #: ###-####
BLD-Footing11/19/201811/20/201811/20/2018APART
DetailsMike Jordan
Marla Phone #: ###-####
BLD-Framing/Rough-in11/16/201811/16/201811/16/2018PPASS
DetailsJim Storey
Call half hour before // Marla or ###-#### Ella Phone #: ###-####
BLD-Framing/Rough-in11/16/201811/16/201811/16/2018ACANC
DetailsJim Sly
I added this on my list so I could see the history of inspections......and explain to the customer what defer......and NH means since she had to get on line to find out the result of her framing inspection. she said.....no notifications left on site.
BLD-Framing/Rough-in11/14/201811/15/201811/15/2018ANH
DetailsBrandon Shaw
Marla Phone #: ###-####
BLD-Framing/Rough-in11/13/201811/14/201811/14/2018ADEFR
DetailsJim Storey
Marla Phone #: ###-#### out of time
Plan assigned to (BJM)10/22/201810/22/201810/26/2018 DONE
DetailsBrian McGowan
Routing - PLAN CHECK10/22/2018 10/26/2018 PASS
DetailsBrian McGowan
Routing - PLANNING10/23/2018 10/26/2018 PASS
DetailsSue Cummings
Modifying/rebuilding existing front and rear porches
Case Summary (BLD)  10/26/2018 DONE
DetailsBrian McGowan
Inspection Record Card- Bld  10/26/2018 DONE
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  10/26/2018 DONE
DetailsBrian McGowan
Permit Ready to Issue  10/26/2018 DONE
Plan Mod Approved
DO NOT REISSUE
Telephone call  10/26/2018 DONE
Spoke to Marla to inform her the plan mod is done and what fees are due.
CHANGE STATUS TO (ISS)  10/26/2018 DONE
Plan Modification Accepted  10/22/2018 DONE
plan mod accepted-1 set of engineering with drawings from the engineer-took to Brian McGowan
Plan assigned to (BJM)9/14/20189/14/20189/26/2018 DONE
DetailsBrian McGowan
plan mod for res remodel
Routing - PLAN CHECK9/26/2018 9/26/2018 PASS
DetailsBrian McGowan
Case Summary (BLD)  9/26/2018 DONE
DetailsBrian McGowan
Inspection Record Card- Bld  9/26/2018 DONE
DetailsBrian McGowan
Permit Ready to Issue  9/26/2018 DONE
Plan Mod Approved
DO NOT REISSUE (fees due)
Telephone call  9/26/2018 DONE
Spoke with Marla to inform her the plan mod and what fees are due
CHANGE STATUS TO (ISS)  9/26/2018 DONE
BLD-Conference9/17/20189/17/20189/17/2018PDONE
DetailsJim Sly
Ella Phone #: ###-####
Under floor....concrete and framing....OK
Routing Walk-In (BLD)9/17/20189/17/20189/17/2018APASS
DetailsJosh Bogle
I had a conversation with Marla about how to handle inspections while waiting for the Modification Review
BLD-Foundation9/14/20189/14/20189/14/2018PDONE
DetailsJim Storey
Marla ###-#### or Elenor Phone #: ###-####
Plan Modification Accepted  9/14/2018 DONE
received 1 packet (10 pgs) structural details and calcs; taken to Brian M.
BLD-Concrete9/6/20189/6/20189/6/2018PPASS
DetailsJim Storey
marla Phone #: ###-####
BLD-Concrete9/5/20189/5/20189/6/2018PNR
DetailsJim Sly
Marla Phone #: ###-####
Routing Walk-In (BLD)6/13/20186/13/20186/13/2018PDONE
DetailsBrian McGowan
1st review completed  6/13/2018 DONE
DetailsBrian McGowan
Routing - PLAN CHECK6/13/2018 6/13/2018 PASS
DetailsBrian McGowan
Case Summary (BLD)  6/13/2018 DONE
DetailsBrian McGowan
Inspection Record Card- Bld  6/13/2018 DONE
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  6/13/2018 DONE
DetailsBrian McGowan
Permit Ready to Issue  6/13/2018 DONE
Issue PAID IN FULL permit  6/13/2018 DONE
Routing Walk-In (BLD)1/9/20181/9/20181/9/2018PFAIL
DetailsJosh Bogle
needed some structural details on the plan
Routing - PLAN CHECK1/9/2018 1/9/2018 FAIL
DetailsJosh Bogle
1st review completed  1/9/2018 FAIL
DetailsJosh Bogle
BLD-Footing9/6/20189/6/2018 P 
DetailsJim Sly
Marla 208 870 1631
Application received 1/9/2018