BLD-Final | 1/3/2019 | 1/3/2019 | 1/3/2019 | P | PASS |
Brandon Shaw
|
|
|
Phone #: ###-#### Inspection requested via web by Gus Brandon
|
DOC - Permit Finaled | 1/3/2019 | 1/3/2019 | 1/3/2019 | P | PASS |
Brandon Shaw
|
|
|
|
BLD-Blower Door Test Results | 1/3/2019 | 1/3/2019 | 1/3/2019 | P | DONE |
Brandon Shaw
|
|
|
ACH50- 3.79
|
BLD-Energy code compliance | 10/25/2018 | 10/25/2018 | 10/25/2018 | P | PASS |
Brandon Shaw
|
|
|
Phone #: ###-#### Inspection requested via web by Kyle Seick
|
BLD-Framing/Rough-in | 10/24/2018 | 10/25/2018 | 10/25/2018 | A | PASS |
Brandon Shaw
|
|
|
Corrections SAT...
OK to insulate
|
BLD-Other | 10/24/2018 | 10/25/2018 | 10/25/2018 | A | PASS |
Brandon Shaw
|
|
|
Soffit Inspection Phone #: ###-#### Inspection requested via web by Kyle Seick
|
BLD-Framing/Rough-in | 10/23/2018 | 10/24/2018 | 10/24/2018 | A | FAIL |
Brandon Shaw
|
|
|
As per plans- plan note # 10 A34 framing anchors at 24" o.c., 3 locations... Plan note # 9- 10' strap at beam to over height wall... Provide straps at break in double top plates... See red paint OK to insulate
|
BLD-Wall Bracing | 10/23/2018 | 10/24/2018 | 10/24/2018 | A | PASS |
Brandon Shaw
|
|
|
OK to cover
|
BLD-Wall Bracing | 10/23/2018 | 10/23/2018 | 10/23/2018 | P | FAIL |
Brandon Shaw
|
|
|
Hold downs are to be as per plans and installed per Man. Rec... Anchor bolts to be no more than 12" from ends of sill plates
|
BLD-Wall Bracing | 10/17/2018 | 10/18/2018 | 10/18/2018 | A | FAIL |
Jim Storey
|
|
|
Phone #: ###-#### Inspection requested via web by Kyle Seick covered w/o insp
|
BLD-Foundation | 8/22/2018 | 8/23/2018 | 8/23/2018 | P | PASS |
Brandon Shaw
|
|
|
Work in progress
|
BLD-Conference | 8/22/2018 | 8/23/2018 | 8/22/2018 | P | CANC |
Brandon Shaw
|
|
|
As late as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell Inspection cancelled via mobile web on Wednesday, August 22, 2018.
|
BLD-Footing | 8/22/2018 | 8/22/2018 | 8/22/2018 | P | PASS |
Brandon Shaw
|
|
|
As early as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell
|
Issue PAID IN FULL permit | | | 8/16/2018 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 8/16/2018 | | |
|
|
|
|
OVERRIDE | | | 5/11/2018 | | |
|
|
|
|
Plan assigned to (RDP) | 5/9/2018 | 5/9/2018 | 5/11/2018 | | DONE |
Rob Patrick
|
|
|
5/22 sfd L1 ePlan
|
Routing - PLAN CHECK | 5/9/2018 | | 5/11/2018 | | PASS |
Rob Patrick
|
|
|
|
1st review completed | | | 5/11/2018 | | DONE |
Rob Patrick
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/11/2018 | | DONE |
Rob Patrick
|
|
|
|
Permit Ready to Issue | | | 5/11/2018 | | DONE |
|
|
|
|
Route to Impact Fee Review | 5/9/2018 | 5/12/2018 | 5/10/2018 | | PASS |
Eric Bilimoria
|
|
|
Initial residential review of new SFD permits requested for now.
|
Routing - MECHANICAL | 5/9/2018 | | 5/10/2018 | | PASS |
Troy James
|
|
|
|
Routing - PLANNING | 5/9/2018 | | 5/9/2018 | | PASS |
Sue Cummings
|
|
|
|
Routing - Addressing | 5/9/2018 | | 5/9/2018 | | PASS |
Doug Chausow
|
|
|
|
Routing - PUBLIC WORKS | 5/9/2018 | | 5/9/2018 | | PASS |
Morgan Webb
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 5/9/2018 | | DONE |
|
|
|
|
Intake Approval | | | 5/9/2018 | | PASS |
|
|
|
|
Application received | | | 5/7/2018 | | DONE |
|
|
|
Application submitted via PDS Online on May 7 2018 4:01PM
|