Information based on query as of Saturday, May 4, 2024.
Permit Information
Permit NumberBLD18-03289
StatusFinaled
Name HHS CONSTRUCTION LLC
Site Address 3817 S ECKERT RD
Project NameBJ 16-2 Sherman
Customer Number 
ePlanReviewYes
Description
Permit for the construction of a new 2414 sq. ft., two story (first story 1260 sq. ft., second story 1154 sq. ft.) single family dwelling with 3 bedrooms, 2.5 bathrooms, approximately 371 sq. ft. of covered patio/porch and a 659 sq. ft. attached garage per the approved plans and any notations. SP-01 zoning and setbacks per planning. Prescriptive Energy Code is proposed. ***BJM***
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Blower Door Test Results4/24/20194/26/20194/26/2019ACANC
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Gus Brandon
BLD-Final4/24/20194/26/20194/26/2019ACANC
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Gus Brandon
BLD-Final4/23/20194/25/20194/25/2019APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Gus Brandon
DOC - Permit Finaled4/25/20194/25/20194/25/2019PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results4/23/20194/25/20194/25/2019ADONE
DetailsBrandon Shaw
ACH50- 4.34
BLD-Other2/22/20192/22/20192/22/2019PPASS
DetailsBrandon Shaw
Soffit Phone #: ###-#### Inspection requested via web by Gus Brandon
BLD-Energy code compliance2/13/20192/19/20192/19/2019APASS
DetailsBrandon Shaw
Corrections SAT...
BLD-Energy code compliance2/14/20192/15/20192/15/2019PFAIL
DetailsBrandon Shaw
Complete all corrections...
Do Not Cover...
BLD-Framing/Rough-in2/12/20192/12/20192/12/2019PFAIL
DetailsBrandon Shaw
Redo all shear nailing...
Hold downs to be installed as per plans...
Anchor bolts to be no more than 12" from ends of sill plates...
Truss hangres to be positively connected to truss/ wall...
Interior walls to be positively connected to sub-flooring...
Per plans- (2) 11 7/8 LVL to be installed per Engineering...
3 ply truss to bear down to foundation...
Per shear pg- CS16 strap with blocking at over height wall...
Per framing page, Over height wall framing- (2) 2x6 DF #2 at 16" O.C.
Routing - MECHANICAL2/6/2019 2/6/2019 PASS
DetailsTroy James
Resubmitted manual j report
BLD-Wall Bracing1/24/20191/25/20191/25/2019PFAIL
DetailsBrandon Shaw
Not ready...
Hold downs and anchor bolts missing in garage...
See red paint...
Garage only...
BLD-Foundation11/21/201811/21/201811/21/2018PPASS
DetailsBrandon Shaw
Work in progress
BLD-Foundation11/20/201811/21/201811/21/2018ACANC
DetailsBrandon Shaw
As early as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell Inspection cancelled via mobile web on Wednesday, November 21, 2018.
BLD-Footing11/19/201811/20/201811/20/2018APASS
DetailsBrandon Shaw
Work in progress
Issue PAID IN FULL permit  10/29/2018 DONE
Inspection Record Card- Bld  10/29/2018 DONE
OVERRIDE  10/26/2018  
Plan assigned to (BJM)9/18/20189/18/201810/26/2018 DONE
DetailsBrian McGowan
10/1 sfd L1 ePlan- 1st Review Complete - Additional Corrections Required
Routing - PLAN CHECK10/26/2018 10/26/2018 PASS
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  10/26/2018 DONE
DetailsBrian McGowan
Permit Ready to Issue  10/26/2018 DONE
met
Routing - PLAN CHECK10/26/2018 10/17/2018 FAIL
DetailsBrian McGowan
Needs to add holddowns on foundation plan
1st review completed  10/1/2018 FAIL
DetailsBrian McGowan
Routing - PLAN CHECK9/18/2018 10/1/2018 FAIL
DetailsBrian McGowan
Route to Impact Fee Review9/18/20189/21/20189/19/2018 PASS
DetailsEric Bilimoria
Initial residential review of new SFD permits requested for now.
Routing - MECHANICAL9/18/2018 9/19/2018 PASS
DetailsTroy James
Routing - Addressing9/18/2018 9/19/2018 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS9/18/2018 9/18/2018 PASS
DetailsMorgan Webb
Plans ACCEPTED BY PLAN TECH  9/18/2018 DONE
Intake Approval  9/18/2018 PASS
Recd Pcfee & Taken To Pln CK  9/18/2018 DONE
Routing - PLANNING9/18/2018 9/18/2018 PASS
DetailsSue Cummings
Application received  9/7/2018 DONE
Application submitted via PDS Online on Sep 7 2018 2:35PM