Permit Information
Permit NumberBLD19-00782
StatusFinaled
Name KING BUILDING & REMODELING
Site Address 2115 W BANNOCK ST
Project NameNew Duplex
Customer NumberDEMO BLD19-00683
ePlanReviewYes
Description
(2115 & 2113 Bannock St.) Permit for the construction of a new 4173 sq. ft. duplex. Unit 1 is 3229 sq. ft. with 5 bedrooms, 3 bathrooms, approximately 106 sq. ft. of covered patio/porch and 631 sq. ft. attached garage. Unit 2 is 944 sq. ft. with 2 bedrooms, 1 bathrooms, approximately 54 sq. ft. of covered patio/porch and 669 sq. ft. attached garage. All work per the approved plans and any notations. Rescheck Energy Compliance. R-3D zoning and setbacks per planning. ***RDP***
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/20/20202/21/20202/21/2020PPASS
DetailsDave Hannah
Ren Phone #: ###-####
DOC - Permit Finaled2/21/20202/21/20202/21/2020PPASS
DetailsDave Hannah
BLD-Aging Inspection2/13/20202/13/20202/19/2020 PASS
DetailsDave Hannah
BLD-Aging Inspection2/12/20202/12/20202/19/2020 PASS
DetailsDave Hannah
BLD-Conference2/18/20202/18/20202/18/2020PDONE
DetailsDave Hannah
Ren Phone #: ###-####
BLD-Framing/Rough-in9/30/201910/1/201910/1/2019APASS
DetailsDave Hannah
Ren Phone #: ###-####
BLD-Energy code compliance10/1/201910/1/201910/1/2019PPASS
DetailsDave Hannah
BLD-Framing/Rough-in9/13/20199/13/20199/13/2019PPASS
DetailsDave Hannah
BLD-Energy code compliance9/12/20199/13/20199/13/2019PPART
DetailsDave Hannah
Ren Phone #: ###-#### air seal ok
BLD-Footing9/4/20199/4/20199/4/2019PPASS
DetailsDave Hannah
before 2:30 // Ren Phone #: ###-####
BLD-Wall Bracing8/9/20198/9/20198/9/2019PPASS
DetailsDave Hannah
REN Phone #: ###-####
BLD-Foundation6/14/20196/14/20196/14/2019PPASS
DetailsDave Hannah
BLD-Wall Bracing6/13/20196/13/20196/14/2019PNR
DetailsDave Hannah
stem wall // Ren Phone #: ###-####
BLD-Footing6/11/20196/11/20196/11/2019PPASS
DetailsDave Hannah
trying to pour at 1:15 // Ren Phone #: ###-####
BLD-Wall Bracing5/10/20195/13/20195/13/2019PCANC
DetailsDave Hannah
stem wall // Ren Phone #: ###-####
BLD-Foundation5/13/20195/13/20195/13/2019PPASS
DetailsDave Hannah
basement walls
BLD-Footing5/1/20195/3/20195/3/2019APASS
DetailsDave Hannah
Ren Phone #: ###-####
BLD-Footing4/26/20194/29/20194/29/2019APASS
DetailsDave Hannah
Ren Phone #: ###-####
Inspection Record Card- Bld  4/5/2019 DONE
Issue PAID IN FULL permit  4/5/2019 DONE
Telephone call  4/4/2019 DONE
emailed JON@KINGBUILTIDAHO.COM that all fees were not paid asked them to let us know when paid so we can print permits out for them and once signed we can sign off on the approved drawings
OVERRIDE  4/3/2019  
Plan assigned to (RDP)3/14/20193/14/20194/3/2019 DONE
DetailsRob Patrick
04/02 Duplex L2 ePlan...03/28 Failed
Routing - PLANNING4/3/2019 4/3/2019 PASS
DetailsKatelyn Menuge
Routing - PLAN CHECK4/3/2019 4/3/2019 PASS
DetailsRob Patrick
PLANS/APPL TAKEN TO FRONT DESK  4/3/2019 DONE
DetailsRob Patrick
Permit Ready to Issue  4/3/2019 DONE
MET-(fees added)
Waiting to hear back from Karina about PRK not having fees
1st review completed  3/28/2019 FAIL
DetailsRob Patrick
Corrections req'd
Routing - PLAN CHECK3/14/2019 3/28/2019 FAIL
DetailsRob Patrick
Corrections req'd
Route to Impact Fee Review3/14/20193/17/20193/15/2019 PASS
DetailsEric Bilimoria
Initial residential review of new SFD permits requested for now.
Routing - MECHANICAL3/14/2019 3/15/2019 PASS
DetailsTroy James
Routing - PLANNING3/14/2019 3/15/2019 FAIL
DetailsKatelyn Menuge
See changemark and submit approval from Idaho Power approving clearance from overhead utilities.
Routing - Addressing3/14/2019 3/14/2019 PASS
DetailsDoug Chausow
2113 and 2115 W Bannock St
Routing - PUBLIC WORKS3/14/2019 3/14/2019 PASS
DetailsMorgan Webb
Intake Approval  3/14/2019 FAIL
The new drawings you uploaded are 11x8 sheet size and we need all drawings to be 24x18 or larger. Please re-upload: Cover Sheet, L-01 Site, A-04 2nd floor plan, A-03 1st floor plan and A-02 Basement floor plan and resubmit.
Plans ACCEPTED BY PLAN TECH  3/14/2019 DONE
Recd Pcfee & Taken To Pln CK  3/14/2019 DONE
Intake Approval  3/14/2019 PASS
Intake Approval  3/13/2019 FAIL
emailed applicant to inform them the drawing file names are incorrect and that we have deleted all drawings and for them to reupload with the correct file names.
Intake Approval  3/13/2019 FAIL
2nd Prescreen: Cover sheet states that you are using 2012 IRC code year. We are in the 2015 IRC code year, please update your cover sheet and any plans that state 2012 IRC to the 2015 IRC year and resubmit.
Application received  3/12/2019 DONE
Application submitted via PDS Online on Mar 12 2019 4:40PM