Final | 7/2/2015 | 7/2/2015 | 7/2/2015 | A | PASS |
Eric Story
|
|
|
please call if you have any questions home owner is on site he has moved some items in garage and will move anything that you need moved. Phone #: ###-#### Inspection requested via web by Shaun Kirkman house final ok
|
Electrical Rough-In | 6/26/2015 | 6/26/2015 | 6/26/2015 | P | PASS |
Eric Story
|
|
|
floor heat in master bath Phone #: ###-#### Inspection requested via web by Shaun Kirkman master bath floor ht rough-in ok cover
|
Rough-In Permanent Service | 2/18/2015 | 2/18/2015 | 2/18/2015 | P | PASS |
Cevyn Recla
|
|
|
Corrections have been made Phone #: ###-#### Inspection requested via web by Shaun Kirkman corrections made, RI OK, PS, UG, N, OK
|
Rough-In Permanent Service | 2/12/2015 | 2/12/2015 | 2/12/2015 | A | FAIL |
Cevyn Recla
|
|
|
Gate code is #1599 Phone #: ###-#### Inspection requested via web by Shaun Kirkman Fire boxes in soffits need to be sealed and fire caulked at penetrations. No permit is pulled on solar installation 110.12 A unsused openings shall be closed BCC 4.05.25 Rough in inspectio required and shall include all mechanical installations, ground wire for solar? 360.12 FMT not permitted in runs over 6 foot in length called Shaun Evengreen Tech is doing solar and will be permitting their own
|
Issue PAID IN FULL permit | | | 2/2/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/2/2015 | | DONE |
|
|
|
This permit was created on the web by Shaun Kirkman
|