Permit Information
Permit NumberMEC19-01650
StatusFinaled
Name LEGENDS MECHANICAL LLC
Site Address 13827 W MEADOWDALE ST
Project Name 
Customer Number 
ePlanReviewNo
Description
New: Complete havac install
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/24/20197/25/20197/25/2019APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok- card signed
Final7/22/20197/23/20197/23/2019PPART
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Gary Reeves- need to remove stucco from around gas piping and seal weather tight- rest is good- recall in when correction made
Pressure Test5/17/20195/17/20195/17/2019PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass whole system- tagged meter location
Rough-in5/17/20195/17/20195/17/2019PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok- fire damper shown on prints has been talked to with engineer ok to omit by Justin Beaucannon with KB associates per document onsite 5-17-19
Rough-in5/13/20195/14/20195/14/2019AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Gary Reeves- outside air needs to be 8" round to each unit per prints and cannot tie in R/A register can needs to tie into plenum both are ran in 6" to 8" wye at wall- print M-1 shows 2 firedampers in chase first floor none are installed- electric heater in 1st floor stairwell needs installed- missing supply and transfer in closet SW corner 1st floor per prints- whos doing gas line ?- left correction notice front window
Issue PAID IN FULL permit  4/23/2019 DONE
Payment received via Govolutions
Owner Supplied Equipment  4/23/2019  
Application received  4/23/2019 DONE
This permit was created on the web by Gary Reeves
First Notice7/25/20197/25/2019   
DetailsBrian Scoles