Permit Information
Permit NumberMEC19-02812
StatusFinaled
Name THE HEATING AND COOLING COMPANY
Site Address 2717 S SIMSBURY LN
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Complete HVAC system with gas piping
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/2/201910/3/201910/3/2019PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Bob Ferrin- final ok
Rough-in7/25/20197/25/20197/25/2019PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Bob Ferrin- crawl ok
Rough-in7/23/20197/24/20197/24/2019AFAIL
DetailsBrian Scoles
Crawl is complete Phone #: ###-#### Inspection requested via web by Bob Ferrin- ducting in crawl needs to maintain 4" off ground- insultion on wye branches is coming off and exposed fiberglass showing- some ducts are pinched between main supply and joist- recall in when corrections are made
Rough-in7/1/20197/2/20197/2/2019APART
DetailsBrian Scoles
Preston Phone #: ###-####- R/I ok ok to sheetrock- crawl wet contractor will schedule another R/I inspection when crawls completed
Rough-in6/28/20197/1/20197/1/2019AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Bob Ferrin-
1- need approved man j onsite for inspection
2- seal all spot welds on return air registers
3- remove hanger straps on csst in walls and use csst nail plate in bedroom at ceiling to bbq
4- secure all gas line in high garage to trusses
5- crawls need completed on R/I
6- dryer duct needs to maintain 4" round smashed by nail plate at ceiling needs notched bigger
Pressure Test7/1/20197/1/20197/1/2019APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Bob Ferrin- 20lb gas pass tagged meter location
Review - MECHANICAL7/1/20197/1/20197/1/2019 DONE
DetailsChad Schwendiman
Revised acca report
Issue PAID IN FULL permit  6/28/2019 DONE
Payment received via Govolutions
Application received  6/28/2019 DONE
This permit was created on the web by Bob Ferrin