Final | 7/2/2020 | 7/6/2020 | 7/6/2020 | A | PASS |
Jack Reynolds
|
|
|
Inspection requested via web by Sarah Small - R/I ok
|
Fees Due Hold | 7/2/2020 | | 7/2/2020 | | DONE |
|
|
|
|
Final | 7/1/2020 | 7/2/2020 | 7/2/2020 | A | FAIL |
Jack Reynolds
|
|
|
Please use access code 4888 Phone #: ###-#### Inspection requested via web by Sarah Small - fees need paid
|
Rough-in | 6/30/2020 | 7/1/2020 | 7/1/2020 | A | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Sarah Small - corrections still need made - reinspection fee applied
|
Rough-in | 6/16/2020 | 6/18/2020 | 6/18/2020 | A | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Sarah Small - section of b vent still needs replaced has screw through inner liner - add all exhaust fans to permit details
|
Pressure Test | 6/16/2020 | 6/18/2020 | 6/18/2020 | A | PASS |
Jack Reynolds
|
|
|
Gas Pressure Test Phone #: ###-#### Inspection requested via web by Sarah Small - 5lb flue test ok - 20lb gas test ok - tagged meter location
|
Rough-in | 6/15/2020 | 6/16/2020 | 6/16/2020 | A | FAIL |
Jack Reynolds
|
|
|
Access Code: 4888 Phone #: ###-#### Inspection requested via web by Sarah Small - b vent needs replaced at roof line and needs 1" clearance to flex - all bedrooms need transfer air openings - toe kick in kitchen needs ducted out of cabinet - add all exhaust fans to permit details
|
Pressure Test | 6/15/2020 | 6/16/2020 | 6/16/2020 | A | FAIL |
Jack Reynolds
|
|
|
Gas Pressure Test - Access Code: 4888 Phone #: ###-#### Inspection requested via web by Sarah Small - gas line needs either disconnected from meter or a tell tale valve installed - new pvc flue for furnace needs tested
|
Issue PAID IN FULL permit | | | 5/27/2020 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 5/27/2020 | | DONE |
|
|
|
This permit was created on the web by Sarah Small
|