Permit NumberBLD06-02316
StatusFinaled
Name ESI
Site Address 3075 W CRESCENT RIM DR
Project NameCrescent Rim #1 - Footings etc
Customer NumberPERMIT IS IN E PLAN
ePlanReviewNo
Description
(CRESCENT RIM RESIDENTIAL CONDOMINIUM BUILDING #1 – PARKING GARAGE, FOOTINGS, AND FOUNDATION – DRH05-00397, DRH18-00199, AND CUP05-00015) The NFPA 13-R fire sprinkler system will be used for occupancy (NFPA 13 for garage). (11-28-18 PLAN MODIFICATION TO REVISE TWO COLUMN FOOTINGS TO ACCOMMODATE EXISTING CONDITIONS (I.E. PROVIDE A MAT FOOTING FOR ONE COLUMN AND TO ATTACH THE OTHER COLUMN TO A FOUNDATION WALL), TO PROVIDE A WIDER CONCRETE FOOTING THAN FORMERLY DESIGNED, TO PROVIDE A NEW SOIL RETAINING WALL AT AN EXISTING OPENING IN THE CONCRETE WALL OF THE BASEMENT GARAGE, AND TO PROVIDE HEADER REINFORCEMENT DETAILS FOR A NEW 42” X 42” EXHAUST AIR OPENING IN THE EXISTING CONCRETE WALL OF THE BASEMENT GARAGE.) This project description replaces all previous descriptions for the parking garage, footings, and foundations. The 3 story apartment building with 19 dwelling units located above the parking garage having 38 parking spaces and additional work within the garage (i.e. interior finishes, electrical, plumbing, mechanical, elevators, etc.) will be constructed under permit BLD06-02322. Existing and new work is required to comply with all applicable codes and ordinances in effect on August 11, 2006, the original date of permit application (e.g. 2003 IBC). To construct new concrete footings and foundations around a previously approved 17,726 square foot post tensioned concrete deck located at grade to support the expanded 3 story residential condominium building that will be constructed under permit BLD06-02322. The work is to include concrete footings, concrete piers, concrete stem walls, concrete slabs on grade, slab edge insulation, and hold downs for future shear walls. No vertical construction above the concrete foundations is allowed under this permit. Drawings showing work above the foundations are for reference only. Special Inspection is required for soils, concrete, and post-installed anchors in hardened concrete. Before any holes are drilled through or into the post tensioned concrete deck, rebar is required to be located (e.g. scanned with ground penetrating radar), to precisely determine the location of concrete reinforcement. No concrete reinforcement is allowed to be cut, including post tensioned cables. This requirement applies to holes for anchor bolts, plumbing pipes, electrical conduit, etc. The work is required to comply with the approved drawings, with the plan review report, with the Structural Engineer’s design, and with all applicable codes and ordinances. This permit is not intended to establish a Certificate of Occupancy for any portion of this building. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/12/20202/12/20202/12/2020PPASS
DetailsJim Storey
DOC - Permit Finaled2/12/20202/12/20202/12/2020PPASS
DetailsJim Storey
BLD-Final1/30/20201/31/20202/3/2020PPASS
DetailsJim Storey
lee Phone #: ###-####
BLD-Aging Inspection1/24/20201/24/20201/30/2020 PASS
DetailsJim Storey
BLD-Other10/11/201910/11/201910/11/2019PPASS
DetailsJim Storey
fire culking // Lee Scott Phone #: ###-####
BLD-Aging Inspection9/12/20199/12/20199/12/2019 PASS
DetailsJim Storey
wip
BLD-Aging Inspection9/11/20199/11/20199/12/2019 PASS
DetailsJim Storey
wip
BLD-Framing/Rough-in5/2/20195/3/20195/3/2019ACANC
DetailsJim Sly
Lee- area A 3rd floor Phone #: ###-####
BLD-Framing/Rough-in4/30/20194/30/20194/30/2019PPART
DetailsJim Sly
inspection for area A 3rd floor- Lee Phone #: ###-####
1st walk thru......Framing Generally appears OK. Need to complete all trade rough-in inspections Provide listings for all firestopping......complete firestopping per listings.
BLD-Other4/9/20194/10/20194/10/2019PPART
DetailsJim Sly
roof nailing // Lee Phone #: ###-####
BLD-Wall Bracing3/21/20193/21/20193/21/2019PPART
DetailsJim Sly
Lee Phone #: ###-####
North 1/2 of structure........OK.
BLD-Footing1/30/20191/31/20191/31/2019APART
DetailsDave Hannah
Lee Phone #: ###-#### ok after spec inspection oks
BLD-Footing1/24/20191/25/20191/25/2019APART
DetailsJim Storey
Lee Scott Phone #: ###-#### wip si pending grade beam and ft with colms south east coner 60 inch culvert.
BLD-Footing1/2/20191/3/20191/3/2019APART
DetailsBrandon Shaw
OK pending STRATA special insp. tests and approvals.
BLD-Footing12/19/201812/20/201812/20/2018APART
DetailsJim Sly
Lee Scott Phone #: ###-####
Southwest corner of Bldg....OK pending STRATA special insp. tests and approvals.
BLD-Foundation11/30/201812/3/201812/3/2018PPART
DetailsJim Sly
Lee Phone #: ###-####
Select Walls OK pending STRATA special inspections, tests and approvals .........and cold weather provisions per ACI 318 standards.
BLD-Footing11/28/201811/29/201811/29/2018APART
DetailsJim Storey
Lee Phone #: ###-#### placed w s/i
BLD-Foundation11/20/201811/21/201811/21/2018APART
DetailsJim Storey
Lee Phone #: ###-#### placed with si pending reports
BLD-Aging Inspection10/22/201510/22/201510/22/2015 PEND
DetailsPhil Shearer
BLD-Aging Inspection7/23/20157/23/20157/23/2015 PEND
DetailsPhil Shearer
BLD-Aging Inspection4/22/20154/22/20154/22/2015 PEND
DetailsPhil Shearer
BLD-Aging Inspection1/21/20151/21/20151/21/2015 PART
DetailsPhil Shearer
BLD-Aging Inspection10/22/201410/22/201410/22/2014 PART
DetailsPhil Shearer
Work in progress
BLD-Aging Inspection4/17/20144/17/20144/17/2014 DONE
DetailsTom Arcoraci
BLD-Aging Inspection1/16/20141/16/20141/21/2014 PEND
DetailsTom Arcoraci
BLD-Aging Inspection10/8/201310/8/201310/8/2013 PEND
DetailsTom Arcoraci
BLD-Aging Inspection7/9/20137/9/20137/9/2013 PEND
DetailsTom Arcoraci
BLD-Aging Inspection4/9/20134/9/20134/9/2013 PEND
DetailsTom Arcoraci
BLD-Aging Inspection1/8/20131/8/20131/8/2013 PEND
DetailsTom Arcoraci
BLD-Aging Inspection10/9/201210/9/201210/9/2012 PEND
DetailsTom Arcoraci
BLD-Aging Inspection7/10/20127/10/20127/10/2012 PEND
DetailsTom Arcoraci
BLD-Aging Inspection4/10/20124/10/20124/10/2012 PEND
DetailsTom Arcoraci
BLD-Aging Inspection1/10/20121/10/20121/11/2012 PASS
DetailsTom Arcoraci
BLD-Aging Inspection10/11/201110/11/201110/11/2011 PASS
DetailsTom Arcoraci
BLD-Aging Inspection7/12/20117/12/20117/12/2011 PASS
DetailsTom Arcoraci
BLD-Aging Inspection4/11/20114/11/20114/11/2011 PART
DetailsTom Arcoraci
BLD-Aging Inspection2/7/20112/7/20112/7/2011 PEND
DetailsTom Arcoraci
BLD-Aging Inspection12/6/201012/6/201012/6/2010 PART
DetailsTom Arcoraci
no
BLD-Aging Inspection10/4/201010/4/201010/4/2010 PART
DetailsTom Arcoraci
BLD-Aging Inspection8/2/20108/2/20108/2/2010 PART
DetailsTom Arcoraci
BLD-Aging Inspection5/31/20105/31/20106/2/2010 PASS
DetailsTom Arcoraci
BLD-Aging Inspection3/29/20103/29/20103/29/2010 PASS
DetailsTom Arcoraci
BLD-Aging Inspection1/26/20101/26/20101/26/2010 PASS
DetailsTom Arcoraci
BLD-Other11/23/200911/23/200911/23/2009PPASS
DetailsTom Arcoraci
BLD-Aging Inspection11/23/200911/23/200911/23/2009 PASS
DetailsTom Arcoraci
BLD-Aging Inspection9/22/20099/22/20099/22/2009 PASS
DetailsTom Arcoraci
BLD-Aging Inspection7/20/20097/20/20097/20/2009 PASS
DetailsTom Arcoraci
BLD-Aging Inspection5/18/20095/18/20095/18/2009 PASS
DetailsTom Arcoraci
BLD-Aging Inspection3/16/20093/16/20093/16/2009 PASS
DetailsTom Arcoraci
BLD-Aging Inspection1/12/20091/12/20091/12/2009 NR
DetailsTom Arcoraci
BLD-Aging Inspection11/11/200811/11/200811/12/2008 CANC
DetailsTom Arcoraci
DOC - Permit Finaled11/12/200811/12/200811/12/2008PCANC
DetailsTom Arcoraci
(This activity was added in error so we have changed the case status back to Issued.)
BLD-Aging Inspection6/9/20086/9/20086/9/2008 PASS
DetailsTom Arcoraci
BLD-Aging Inspection1/9/20081/9/20081/9/2008 PASS
DetailsTom Arcoraci
BLD-Aging Inspection10/31/200710/31/200710/31/2007 NR
DetailsTom Arcoraci
BLD-Aging Inspection8/30/20078/30/20078/30/2007 NR
DetailsTom Arcoraci
BLD-Foundation5/18/20075/21/20075/21/2007APART
DetailsTom Arcoraci
Special inspection by Strata. Pouring at noon. Phone #: ###-#### Internet Inspection Request from: Bob Thornton
BLD-Foundation3/23/20073/26/20073/26/2007APASS
DetailsMike Jordan
Pouring at noon Phone #: ###-####. Reviewed all special insp. reports to date. Everything ok, no non conformances noted.
BLD-Footing11/16/201811/19/2018 A 
DetailsDave Hannah
per Lee has nothing to do with plan mod in review // Lee Phone #: ###-####