DOC - Permit Finaled | | | 11/1/2018 | | DONE |
|
|
|
Per BLD-Final Passed inspection (required signatures say no for c of o)
|
BLD-Final | 10/30/2018 | 10/31/2018 | 10/31/2018 | A | PASS |
Mike Jordan
|
|
|
Charles Phone #: ###-####. Ok for perm occ.
|
FIRE-Final Inspection | 10/30/2018 | 10/30/2018 | 10/30/2018 | P | PASS |
Troy Cobbley
|
|
|
life safety passed
Charles Phone #: ###-####
|
BLD-Framing/Rough-in | 4/27/2018 | 4/30/2018 | 4/30/2018 | P | PASS |
Mike Jordan
|
|
|
Charles Phone #: ###-####. Interior steel stud framed walls at locker rooms.
|
BLD-Framing/Rough-in | 12/21/2017 | 12/21/2017 | 12/21/2017 | A | PASS |
Mike Jordan
|
|
|
Interior steel stud framed walls and soffits, remainder of addiotion ok.
|
BLD-Framing/Rough-in | 9/5/2017 | 9/6/2017 | 9/6/2017 | P | PASS |
Mike Jordan
|
|
|
Jeff Phone #: ###-####. Interior steel stud framed walls for laundry room.
|
BLD-Foundation | 8/18/2017 | 8/21/2017 | 8/21/2017 | A | PART |
Mike Jordan
|
|
|
Jeff-rebar Phone #: ###-####. Footings and column pad footings at gridlines N7 from grids NB to NA. Grid NA from N4 to N7. Grid NA from N2 to N3. Noted some clearance issues. Will have special inspection. Special inspector to verify clearance issues are resolved.
|
BLD-Foundation | 8/10/2017 | 8/14/2017 | 8/14/2017 | A | PASS |
Mike Jordan
|
|
|
Rebar// Charles Phone #: ###-####. Footings and column pad footings on grid N6 from grids NG to NB.
|
BLD-Concrete | 8/7/2017 | 8/8/2017 | 8/8/2017 | P | PASS |
Mike Jordan
|
|
|
rebar- Jeff Phone #: ###-####. Stemwalls on grid NM from grids N2-N4. Interior column pad footings on grid N4 at grids NG, NF and NC.
|
BLD-Foundation | 8/1/2017 | 8/2/2017 | 8/2/2017 | P | PASS |
Mike Jordan
|
|
|
Interior column moment frame footings on grids N2 and N3 are now per detail 1/S5.10. Footings and column pad footings on gridline NM from N1 to N4, and N4 from NM to NH and NH from N4 to N7 are ok to place. Will also have specail inspection.
|
BLD-Foundation | 8/1/2017 | 8/1/2017 | 8/1/2017 | P | CANC |
Mike Jordan
|
|
|
Rebar inspection. Moved to pm on 8-2-17.
|
BLD-Footing | 7/21/2017 | 7/24/2017 | 7/24/2017 | A | PART |
Mike Jordan
|
|
|
F6 type interior column pad footings ok to place. F7T and F8T interior column pad footings missing 33 ties and additional #4 next to anchor bolts. Noted all footings with T designation are moment frmae footings and require the additional rebar per detail 1 in S5-10. Verified with engineer of record. ok to place the F6 footings only.
|
BLD-Footing | 7/21/2017 | 7/21/2017 | 7/21/2017 | P | CANC |
Mike Jordan
|
|
|
|