Permit Information
Permit NumberBLD17-00463
StatusFinaled
Name HAYDEN HOMES IDAHO LLC
Site Address 12487 W IRVING ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Permit for the construction of a new 1408 sq. ft., one story single family dwelling with 3 bedrooms, 2 bathrooms, approximately 162 sq. ft. of covered patio/porch and a 483 sq. ft. attached garage per the approved plans, ResCheck, ACCA report and any notations. R-1C zoning and setbacks per planning.//leg
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/8/20176/8/20176/8/2017PPASS
DetailsDave Hannah
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
DOC - Permit Finaled6/8/20176/8/20176/8/2017PPASS
DetailsDave Hannah
BLD-Energy code compliance4/27/20174/28/20174/28/2017APASS
DetailsMike Jordan
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
BLD-Framing/Rough-in4/28/20174/28/20174/28/2017APASS
DetailsMike Jordan
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
BLD-Framing/Rough-in4/26/20174/27/20174/27/2017AFAIL
DetailsMike Jordan
As early as possible Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Disregard previous framing inspection, done on wrong house. Complete lateral bracing on A02 trusses. Nail off all simpson hangars. Fireblock behind tub in masterbedroom. Repair bottom plate in master bedroom. Strap double top plates at peak on racked walls. Noted several studs in racked walls cut to short.-replace. Ok to insulate. Correction notice posted.
BLD-Framing/Rough-in4/26/20174/26/20174/26/2017PFAIL
DetailsMike Jordan
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Needs to complete foam seal prior to framing inspection. Roll block floor joist at glulam in garage. Provide anchor bolts in garage on bearing wall. Correction notice posted.
BLD-Wall cover4/13/20174/13/20174/13/2017PPART
DetailsMike Jordan
Nate Phone #: ###-####. Exterior wall bracing ok. Did note some tore OSB from crane that needs to be removed and replaced. Noted to framers on site that wall bracing is ok, but to replace OSB and will check on framing inspection.
BLD-Wall Bracing4/12/20174/12/20174/12/2017PNR
DetailsMike Jordan
Shear // Zane Phone #: ###-####
BLD-Foundation3/28/20173/28/20173/28/2017PPASS
DetailsMike Jordan
BLD-Footing3/28/20173/28/20173/28/2017PPASS
DetailsMike Jordan
Footing Inspection was completed by #316, but was entered under wrong permit number (12447 W. Irving)
BLD-Foundation3/22/20173/22/20173/22/2017PCANC
DetailsMike Jordan
Phone #: 2086971241 >> Inspection requested via mobile web by Heron