BLD-Final | 7/9/2018 | 7/9/2018 | 7/9/2018 | P | PASS |
Mike Jordan
|
|
|
garage door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
DOC - Permit Finaled | 7/9/2018 | 7/9/2018 | 7/9/2018 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Blower Door Test Results | 7/9/2018 | 7/9/2018 | 7/9/2018 | P | DONE |
Mike Jordan
|
|
|
garage door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle. 4.7ACH
|
BLD-Energy code compliance | 5/22/2018 | 5/22/2018 | 5/22/2018 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Framing/Rough-in | 5/22/2018 | 5/22/2018 | 5/22/2018 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Framing/Rough-in | 5/21/2018 | 5/21/2018 | 5/21/2018 | P | FAIL |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Complete lateral bracing on A6 truss. LAteral bracing on B2, B3 and B4 trusses connected to wrong member, attach to webs, not top chord. Fireblock at ceiling level in closet in main hallway. Provide additional bracing on top chords of A3 trusses were roof sheathing is stooped. Also roll block. Insuffucient bearing on at sleepers on over builds. Ok to insulate. Correction notice posted.
|
BLD-Energy code compliance | 5/17/2018 | 5/21/2018 | 5/21/2018 | P | CANC |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by Joel Hirtle Inspection cancelled from web by: Joel Hirtle
|
BLD-Framing/Rough-in | 5/17/2018 | 5/18/2018 | 5/18/2018 | P | NR |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle.Mech rough in inspection has failed.
|
BLD-Wall Bracing | 4/25/2018 | 4/25/2018 | 4/25/2018 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Footing | 4/11/2018 | 4/12/2018 | 4/12/2018 | P | PASS |
Mike Jordan
|
|
|
Dane Phone #: ###-####
|