Information based on query as of Monday, May 13, 2024.
Permit Information
Permit NumberBLD18-01611
StatusFinaled
Name HHS CONSTRUCTION LLC
Site Address 4531 E LOGGER DR
Project NameBJ 11-8 Wildflower FH
Customer Number 
ePlanReviewYes
Description
Permit for the construction of a new 2,123 sq. ft., two story (first story 1,318 sq. ft., second story 805 sq. ft.) single family dwelling with 3 bedrooms, 2 and a half bathrooms, approximately 54 sq. ft. of covered patio/porch and a 441 sq. ft. attached garage per the approved plans and any notations. Prescriptive Energy Compliance. SP-01 zoning and setbacks per planning.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/3/20191/3/20191/3/2019PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Gus Brandon
DOC - Permit Finaled1/3/20191/3/20191/3/2019PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results1/3/20191/3/20191/3/2019PDONE
DetailsBrandon Shaw
ACH50- 3.79
BLD-Energy code compliance10/25/201810/25/201810/25/2018PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Kyle Seick
BLD-Framing/Rough-in10/24/201810/25/201810/25/2018APASS
DetailsBrandon Shaw
Corrections SAT...

OK to insulate
BLD-Other10/24/201810/25/201810/25/2018APASS
DetailsBrandon Shaw
Soffit Inspection Phone #: ###-#### Inspection requested via web by Kyle Seick
BLD-Framing/Rough-in10/23/201810/24/201810/24/2018AFAIL
DetailsBrandon Shaw
As per plans- plan note # 10 A34 framing anchors at 24" o.c., 3 locations...
Plan note # 9- 10' strap at beam to over height wall...
Provide straps at break in double top plates...
See red paint
OK to insulate
BLD-Wall Bracing10/23/201810/24/201810/24/2018APASS
DetailsBrandon Shaw
OK to cover
BLD-Wall Bracing10/23/201810/23/201810/23/2018PFAIL
DetailsBrandon Shaw
Hold downs are to be as per plans and installed per Man. Rec...
Anchor bolts to be no more than 12" from ends of sill plates
BLD-Wall Bracing10/17/201810/18/201810/18/2018AFAIL
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Kyle Seick covered w/o insp
BLD-Foundation8/22/20188/23/20188/23/2018PPASS
DetailsBrandon Shaw
Work in progress
BLD-Conference8/22/20188/23/20188/22/2018PCANC
DetailsBrandon Shaw
As late as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell Inspection cancelled via mobile web on Wednesday, August 22, 2018.
BLD-Footing8/22/20188/22/20188/22/2018PPASS
DetailsBrandon Shaw
As early as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell