Permit Information
Permit NumberBLD18-02298
StatusFinaled
Name MICRON TECHNOLOGY INC
Site Address 8000 S FEDERAL WAY
Project NameMicron B17C Executive Suite
Customer Number 
ePlanReviewYes
Description
(MICRON B17C EXECUTIVE SUITE) Permit to remodel approximately 3,000 sq ft on the 4th floor between gridlines 8.1 & 10.1 and J & L. Work to include: interior demolition; installation of new interior non-bearing partition walls; ceiling grid system; interior doors and windows; new kitchenette; new mechanical, electrical, and plumbing; and new interior finishes in compliance with Ch. 8 of the 2015 IBC. All work per the approved plans. This is a fully fire sprinklered building for area increase. Corridors are not required to be rated per IBC 1020.1 based on sprinkler system in accordance with IBC 903.3.1.1. Fire sprinkler plans submitted in 1997 (Microfiche #980242) show quick response heads throughout, which have been verified by Micron (see attached email). Any alterations to the sprinkler system will require a separate permit and shall comply with NFPA 13 as reglated by the fire department. JAR
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/8/20191/9/20191/9/2019PPASS
DetailsJim Storey
Steve Phone #: ###-####
DOC - Permit Finaled1/9/20191/9/20191/9/2019PPASS
DetailsJim Storey
FIRE-Final Inspection1/8/20191/9/20191/9/2019APASS
DetailsJim Page
Final life fire safety inspection for area of work complete.

Steve Phone #: ###-####
BLD-Ceiling Grid Inspection12/27/201812/28/201812/28/2018APASS
DetailsJim Storey
Steve Phone #: ###-#### fire treated wood ok to cover/
BLD-Ceiling Grid Inspection12/6/201812/7/201812/7/2018APART
DetailsJim Storey
t bar // Steve Phone #: ###-#### ceilling grid ok pending trade aprovals need resolve with wood above ceilling not fire treated type of const/and return air pienum.
BLD-Ceiling Grid Inspection12/3/201812/4/201812/4/2018APART
DetailsJim Storey
Steve Phone #: ###-#### no wood alowed above ceilling type of const. and return air plnem/ support mains with in 6 inches of mains/ wiring need verifacation of smoke flame spread/
BLD-Framing/Rough-in9/20/20189/21/20189/21/2018APASS
DetailsJim Storey
Steve Phone #: ###-####