Permit Information
Permit NumberBLD18-02566
StatusIssued
Name KRAFTWERK REMODEL INC
Site Address 515 W IDAHO ST
Project NameOchos - Patios
Customer Number 
ePlanReviewNo
Description
(OCHOS BOISE – ELEVATED PATIOS, PATIO AT GRADE, CANOPY, AWNINGS, AND PERGOLAS) (DRH18-00135) The building fire sprinkler system is used for story increase and for fire area. To construct an elevated patio about 58 inches above grade (about 912 square feet), an elevated patio about 12 inches above grade (about 311 square feet), a patio at grade (about 1,252 square feet), and circulation areas (about 877 square feet). Work is to include concrete footings, masonry retaining and bearing walls, masonry piers, steel columns, steel beams, concrete slab on steel pan deck with pavers, free draining backfill material, pavers installed on fill material, concrete stairways with handrails, curved ramp with handrails, steal pergolas open to the sky with attached radiant heaters, a steel pergola open to the sky over an exterior stairway, a screen wall at the East property line, a 1-hr fire-resistance-rated wall at the East property line next to the awning, fixed benches, guards, a new steel exterior stairway to the basement, a wheelchair lift, a table with open gas flame, and a fire feature with open gas flame. Special Inspection is required for soils, concrete, masonry, steel (including welding), and anchors post-installed in hardened concrete. Work also includes a high glass canopy (390 square feet), two low glass awnings (158 square feet total), and a canopy at the carriage house (59 square feet). The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. This permit is intended to establish a Certificate of Occupancy only for the patio areas. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Conference6/8/20206/8/20206/9/2020PDONE
DetailsDave Hannah
Ed *screened* Phone #: ###-####
FIRE-Final Inspection6/5/20206/8/20206/8/2020AFAIL
DetailsTroy Cobbley
Provide emergency lighting, provide fire extinguisher, provide fire sprinkler protection for canopies due to the presence of the fire pit, provide approved hardware/hinge for the gate as discussed, provide signage at the gas valves as discussed.

Ed *screened* Phone #: ###-####
BLD-Conference11/20/201911/21/201911/21/2019ADONE
DetailsDave Hannah
Ed Phone #: ###-####
FIRE-Final Inspection9/12/20199/13/20199/13/2019ACANC
DetailsJim Page
Previous permit for area of work has not been finaled, BLD17-00634, this permit needs to finaled before any life safety items can be addressed for this permit. Spoke with point of contact, he is going to work on getting BLD17-00634 finaled so we can proceed with this permit. This request is cancelled per conversation with point of contact.

Ed Phone #: ###-####
BLD-Foundation7/11/20197/11/20197/11/2019PPASS
DetailsDave Hannah
Ed-rebar Phone #: ###-####-Dave will you remind Rudy that they need the temp c of o for BLD17-00634?
BLD-Foundation5/21/20195/21/20195/22/2019PPASS
DetailsDave Hannah
Ed-rebar Phone #: ###-####
BLD-Concrete5/21/20195/21/20195/22/2019PPASS
DetailsDave Hannah
Ed-inspection for the pan deck Phone #: ###-####
BLD-Concrete5/6/20195/7/20195/7/2019APASS
DetailsDave Hannah
Ed- rebar Phone #: ###-####
BLD-Footing4/25/20194/25/20194/26/2019PPASS
DetailsDave Hannah
Ed Phone #: ###-####
BLD-Foundation3/7/20193/8/20193/8/2019APASS
DetailsDave Hannah
STEM WALL // Ed Phone #: ###-####
BLD-Foundation3/5/20193/6/20193/6/2019APASS
DetailsDave Hannah
Ed Phone #: ###-####
BLD-Footing12/11/201812/11/201812/11/2018PPART
DetailsBrandon Shaw
Work in progress...