Information based on query as of Saturday, May 11, 2024.
Permit Information
Permit NumberBLD18-03240
StatusFinaled
Name BLUE BIRD BUILDING COMPANY INC
Site Address 10610 W ESTATE DR
Project NameSinclair Residence
Customer NumberMIS18-00144 HOUSE MOVE
ePlanReviewYes
Description
***Prescriptive component energy approach*** Permit for the construction of a new 3331 sq. ft., one story single family dwelling with 5 bedrooms, 3 bathrooms, approximately 421 sq. ft. of covered patio/porch and a 1229 sq. ft. attached garage per the approved plans and any notations. R-1A zoning and setbacks per planning.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/19/20202/19/20202/19/2020PPASS
DetailsMike Jordan
Cody- please call for access Phone #: ###-####
DOC - Permit Finaled2/19/20202/19/20202/19/2020PPASS
DetailsMike Jordan
BLD-Final2/14/20202/18/20202/18/2020AFAIL
DetailsMike Jordan
Cody Phone #: ###-####. Provide landing from on exterior door from master bedroom. provide blower door test rsults.
BLD-Energy code compliance6/27/20196/28/20196/28/2019APASS
DetailsMike Jordan
Coty Phone #: ###-####
BLD-Framing/Rough-in6/27/20196/28/20196/28/2019APASS
DetailsMike Jordan
Coty Phone #: ###-####
BLD-Framing/Rough-in6/11/20196/12/20196/12/2019APART
DetailsMike Jordan
Call ahead // Cody Phone #: ###-####
BLD-Framing/Rough-in5/21/20195/22/20195/22/2019AFAIL
DetailsMike Jordan
Cody Phone #: ###-####. Nail off all multiply trusses per the engineering, B2 E2 and A20. Roll block C2 and C3 trusses. Install hangar on A01 truss for bearing. Install all blocking for Gyp board shear walls.
BLD-Framing/Rough-in5/14/20195/15/20195/15/2019ANR
DetailsJim Storey
Cody Phone #: ###-#### need air seal/ need truss engneering
BLD-Framing/Rough-in4/8/20194/8/20194/8/2019PCANC
DetailsMike Jordan
Phone #: 2082159239 >> Inspection requested via mobile web by Cody
BLD-Wall Bracing4/8/20194/8/20194/8/2019PPASS
DetailsMike Jordan
Phone #: 2082159239 >> Inspection requested via mobile web by Cody
BLD-Framing/Rough-in4/4/20194/5/20194/5/2019AFAIL
DetailsMike Jordan
Call prior to going Phone #: 2082159239 >> Inspection requested via mobile web by Cody. Install all missed blocking, complete portal frames, install holdowns, re nail missed areas on sheathing.
BLD-Foundation2/11/20192/11/20192/11/2019PPART
DetailsMike Jordan
wall- Derik Phone #: ###-####
BLD-Footing2/8/20192/8/20192/8/2019PPART
DetailsMike Jordan
Derik Phone #: ###-####