Permit Information
Permit NumberBLD19-00358
StatusFinaled
Name BERLUM DEVELOPMENT CO
Site Address 2184 E PARKSIDE DR
Project Name2184 Parkside
Customer Number 
ePlanReviewYes
Description
CAT II Hillside Permit. PLAN MOD 3-18-19 NEW SUEZ FIRE FLOW REPORT INDICATES THERE IS ADEQUATE GPM.SPRINKLERS ARE NOT REQUIRED. LGM **HILLSIDE** **WUI FOOTHILLS ZONE A REQUIREMENTS** **SPECIAL INSPECTIONS REQUIRED** **PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 2450 sq. ft., two story (first story 1209 sq. ft., second story 1241 sq. ft.) single family dwelling with 3 bedrooms, 2.5 bathrooms, and a 1108 sq. ft. attached garage per the approved plans and any notations. R-1B zoning and setbacks per planning. JJN A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.

An erosion and sediment control site preparation inspection is required for this site. The site preparation inspection takes place after all required erosion and sediment control best management practices have been installed and BEFORE any earthwork takes place. Call 208-608-7070 to schedule an inspection.



All disturbed slopes included in the construction of this project must be stabilized and approved by Public Works before a Final Occupancy Permit is granted. If weather conditions prohibit revegetation and stabilization activities, the contractor shall provide a bond/surety agreement or an irrevocable letter of credit in the amount of 110% of the cost estimated by the project engineer to enable stabilization of the site. Call 208-608-7168 for an inspection.
SPRINKLERS ARE BEING PROVIDED, AS NOTED ON SITE PLAN. LGM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/14/201911/14/201911/14/2019PPASS
DetailsBrandon Shaw
James Phone #: ###-####
DOC - Permit Finaled11/14/201911/14/201911/14/2019PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results11/14/201911/14/201911/14/2019PDONE
DetailsBrandon Shaw
ACH50- 4.83
BLD-Final11/8/201911/8/201911/8/2019PFAIL
DetailsBrandon Shaw
Need PW grading approval...
BLD-Final11/6/201911/7/201911/7/2019ANR
DetailsBrandon Shaw
Pre final walk thru...
BLD-Energy code compliance7/25/20197/25/20197/25/2019PPEND
DetailsBrandon Shaw
4 additional lights being added to stairs, need ELE rough-in cover approval.
Per Engineering- DF #1 to be used for bearing end of cut trusses...
BLD-Framing/Rough-in7/23/20197/23/20197/23/2019PPEND
DetailsBrandon Shaw
Provide Engineering approval/ revised fix for floor trusses, F6, F7, F19. Bearing end has been cut and/or modified...
BLD-Framing/Rough-in7/23/20197/23/20197/23/2019PPASS
DetailsBrandon Shaw
James Phone #: ###-####
DOC - Permit Finaled7/23/20197/23/20197/23/2019PPASS
DetailsBrandon Shaw
BLD-Wall Bracing7/17/20197/17/20197/17/2019PCANC
DetailsBrandon Shaw
James Phone #: ###-####
BLD-Framing/Rough-in6/19/20196/20/20196/20/2019APASS
DetailsJim Storey
Call ahead // James Phone #: ###-#### ok to remove tub fur out walls.
BLD-Wall Bracing6/13/20196/14/20196/14/2019APASS
DetailsDave Hannah
Jay Phone #: ###-####
BLD-Wall Bracing6/11/20196/11/20196/12/2019PNR
DetailsDave Hannah
James Phone #: ###-#### no plans on site
BLD-Foundation4/24/20194/24/20194/25/2019PPASS
DetailsDave Hannah
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro
BLD-Footing4/12/20194/12/20194/12/2019PPASS
DetailsDave Hannah
Alvalo Phone #: ###-####