BLD-Final | 7/16/2019 | 7/16/2019 | 7/16/2019 | P | PASS |
Mike Jordan
|
|
|
garage door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
DOC - Permit Finaled | 7/16/2019 | 7/16/2019 | 7/16/2019 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Blower Door Test Results | 7/16/2019 | 7/16/2019 | 7/16/2019 | P | DONE |
Mike Jordan
|
|
|
4.95
|
BLD-Final | 7/10/2019 | 7/10/2019 | 7/10/2019 | A | PEND |
Mike Jordan
|
|
|
garage door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle. Needs blower door test results and post. Everything else ok.
|
BLD-Energy code compliance | 5/29/2019 | 5/30/2019 | 5/30/2019 | P | PASS |
Brandon Shaw
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Framing/Rough-in | 5/29/2019 | 5/30/2019 | 5/30/2019 | P | PASS |
Brandon Shaw
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Framing/Rough-in | 5/29/2019 | 5/29/2019 | 5/29/2019 | P | FAIL |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Complete lateral bracing on A08 truss. Fireblock dryer vent chase at ceiling. Install squash blocks on D04 truss, east side. F02 truss placed in wrong location. Complete nailinf of interior shear wall in master bedroom.
|
BLD-Foundation | 4/29/2019 | 4/30/2019 | 4/30/2019 | P | PASS |
Jim Sly
|
|
|
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru
|
BLD-Footing | 4/28/2019 | 4/29/2019 | 4/29/2019 | P | PART |
Mike Jordan
|
|
|
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru
|