Information based on query as of Friday, May 17, 2024.
Permit Information
Permit NumberBLD19-01154
StatusFinaled
Name QUANTUM LTD INC
Site Address 4365 N MORNINGGALE PL
Project NameCamberlango Residence
Customer Number 
ePlanReviewYes
Description
**PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 2836 sq. ft., one story single family dwelling with 4 bedrooms, 2.5 bathrooms, approximately 264 sq. ft. of covered patio/porch and a 786 sq. ft. attached garage per the approved plans and any notations. R-1C zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/11/20202/12/20202/12/2020PPASS
DetailsDave Hannah
Shawn Phone #: ###-####
DOC - Permit Finaled2/12/20202/12/20202/12/2020PPASS
DetailsDave Hannah
BLD-Final2/6/20202/7/20202/7/2020AFAIL
DetailsTell Riley
call for access code Shawn Phone #: ###-#### or ###-#### Marty//plans show r 38 insulation--description is prescriptive of R 49--manual J also shows R49 attic insulation//insulation certificate does not list crawlspace insulation//remove dust covers from smoke and smoke/CO detectors// CN posted onsite//
BLD-Blower Door Test Results2/7/20202/7/20202/7/2020ADONE
DetailsTell Riley
3.78 ACH 50
BLD-Final2/6/20202/7/20202/7/2020ACANC
DetailsTell Riley
Shawn call to cancel, not ready will call to reschedule//Shawn Phone #: ###-####
BLD-Aging Inspection1/2/20201/2/20201/2/2020 PASS
DetailsTell Riley
WIP
BLD-Aging Inspection1/1/20201/1/20201/2/2020 CANC
DetailsTell Riley
BLD-Energy code compliance8/20/20198/20/20198/20/2019PPASS
DetailsTell Riley
Shawn Phone #: ###-####
BLD-Framing/Rough-in8/20/20198/20/20198/20/2019PPASS
DetailsTell Riley
Shawn Phone #: ###-####//correction made//
BLD-Framing/Rough-in8/14/20198/15/20198/15/2019APASS
DetailsTell Riley
Shawn Phone #: ###-####//need to add header in door opening--interior bearing wall next to front door//ok to insulate only//
BLD-Wall Bracing7/24/20197/25/20197/25/2019APASS
DetailsTell Riley
shear // Shawn Phone #: ###-####//corrections made//
BLD-Wall Bracing7/17/20197/18/20197/18/2019APART
DetailsTell Riley
shear // Shawn Phone #: ###-####//need portal frame clarifiaction//all other shear ok//
BLD-Wall Bracing7/12/20197/12/20197/12/2019PFAIL
DetailsTell Riley
shear // shawn Phone #: ###-####//correction notice posted//finish portal frame// verify portal frame over windows//add blocking per plans//
BLD-Foundation5/20/20195/21/20195/21/2019APART
DetailsJim Sly
Shawn Phone #: ###-####
see footing notes.....Rebar etc. in footing and wall....OK.
BLD-Footing5/15/20195/16/20195/16/2019APART
DetailsJim Sly
Nate Phone #: ###-####
Appears OK........but no lines pulled. Really close. pour at own risk.