Information based on query as of Saturday, May 11, 2024.
Permit Information
Permit NumberBLD19-01272
StatusFinaled
Name HC COMPANY INC
Site Address 12601 W EXPLORER DR Unit: 180
Project NameBDC Travel - Suite #180
Customer NumberBLD19-01372
ePlanReviewYes
Description
**(BDC TRAVEL – SUITE #180)** (2 BUILDING PERMITS UNDER BLD19-01272 IN EPLAN) Permit is to remodel an existing 8,101 sq. ft. tenant space by dividing it into two separate tenant spaces, this tenant space is to be 2,967 sq. ft. and the remaining 5,134 sq. ft. is to be an unoccupied tenant space created under BLD19-01372. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select door/door frames and relocate, removal of floor finish, removal of select suspended acoustic ceiling, construction of select interior nonbearing wall to demise tenant spaces, to create an IT room, a breakroom, and an open office area, select wall infill, new floor finish, millwork, select new suspended acoustic ceiling, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fire sprinklered for area increase and 1-hour substitution. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/13/20199/16/20199/16/2019APASS
DetailsTell Riley
John Phone #: ###-####//final complete//
FIRE-Final Inspection9/13/20199/13/20199/13/2019PDONE
DetailsJim Page
Life fire safety inspection for area of work completed on 28JUNE2019.

John Phone #: ###-####
BLD-Final6/28/20196/28/20196/28/2019PPASS
DetailsTell Riley
John Phone #: ###-####//pass for temp occupancy//needs furniture finished install--out a few weeks//
FIRE-Final Inspection6/28/20196/28/20196/28/2019APASS
DetailsJim Page
Fire sprinkler inspection is complete, fire alarm inspection is complete, fire extinguisher is placed with a current inspection tag, suite number will be installed before final BLD inspection. Final life fire safety inspection for area of work complete.
BLD-Ceiling Grid Inspection6/21/20196/21/20196/21/2019PPART
DetailsTell Riley
existing grid ok//new wall attachment pending architect review.//
BLD-Ceiling Grid Inspection6/20/20196/20/20196/20/2019PNR
DetailsTell Riley
John Phone #: ###-####//need HVAC rough in passed// call in re-inspection to discuss ceiling grid plans//
BLD-Framing/Rough-in5/21/20195/21/20195/21/2019PPASS
DetailsJim Sly
John Phone #: ###-####