Permit Information
Permit NumberBLD19-02660
StatusFinaled
Name BURNS WALL AND CEILING LLC
Site Address 8239 W FRANKLIN RD
Project NameMiracle Ear Boise Store
Customer Number 
ePlanReviewYes
Description
(MIRACLE EAR) **This is a partially sprinklered building. The Cafe Rio space is sprinklered for occupant load more than 100 - see BLD10-01207. The 2-hr fire resistance rated fire barrier wall located between Cafe Rio and Miracle Ear creates two fire areas and is required to be maintained.** Permit for remodel to existing 1,100 sq ft office space for new office tenant. Work to include: new interior non-bearing partition walls; new doors new ceiling grid panels with insulation above; interior finishes in compliance with Ch. 8 of the 2015 IBC. This building is partially fire sprinklered for A2 occupant load over 100. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JAR*
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/30/20199/30/20199/30/2019PPASS
DetailsMike Jordan
Tony Phone #: ###-####. Ok for perm occ.
FIRE-Final Inspection9/30/20199/30/20199/30/2019PPASS
DetailsTroy Cobbley
Life safety passed. Tony Phone #: ###-####
BLD-Ceiling Grid Inspection9/27/20199/30/20199/30/2019APASS
DetailsMike Jordan
Brett Phone #: ###-####
BLD-Ceiling Grid Inspection9/27/20199/27/20199/27/2019PPASS
DetailsTell Riley
firecaulk complete//grid ok//
BLD-Ceiling Grid Inspection9/27/20199/27/20199/27/2019PNR
DetailsTell Riley
Tony Phone #: ###-####//need to firecaulk all penetrations through 2 hour wall//
BLD-Ceiling Grid Inspection9/25/20199/26/20199/26/2019ANR
DetailsMike Jordan
Tony Phone #: ###-####. A mech. permit is required for the new and altered duct work that has been installed.
BLD-Framing/Rough-in9/3/20199/3/20199/3/2019PPASS
DetailsMike Jordan
Tony Phone #: ###-####. Walls have been repaired. Inteior steel stud framed walls ok. No grid at this time.
BLD-Framing/Rough-in8/29/20198/30/20198/30/2019AFAIL
DetailsMike Jordan
Tony Phone #: ###-####. Brace testing room walss as required. Firecaulk all penetrations in perimeter fire walls. Correction notice posted.