Information based on query as of Sunday, May 19, 2024.
Permit Information
Permit NumberBLD19-02939
StatusFinaled
Name CARROLL CONSTRUCTION
Site Address 8650 W HACKAMORE DR
Project NameShadows
Customer Number 
ePlanReviewYes
Description
(SHADOWS) //1-23-2020 PLAN MODIFICATION TO EQUIPMENT LAYOUT, MECHANICAL AND ELECTRICAL WORK. Jg// Permit to construct a new 11,145 sq. ft. one story building and related site work. Scope of work includes: construction of footing foundation, slab on grade concrete floor, 8” CMU exterior walls, steel roof joist, electrical work and site work. This building is not fire sprinkled. Note: special inspection required see attached form #310. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/14/20205/15/20205/15/2020PPASS
DetailsMike Jordan
Phone #: 2085591460 >> Inspection requested via mobile web by Aaron Carroll. Ok for perm occ.
BLD-Final4/29/20204/30/20204/30/2020APART
DetailsMike Jordan
Call for access Phone #: 2085591460 >> Inspection requested via mobile web by Aaron Carroll. Ok for temp. occ. Noted vertical grab bars not within the 39 to 41 inch.
FIRE-Final Inspection4/29/20204/30/20204/30/2020APASS
DetailsTroy Cobbley
Life safety passed. Phone #: 2085591460 >> Inspection requested via mobile web by Aaron Carroll
FIRE-Final Inspection4/30/20204/30/20204/30/2020PPASS
DetailsTroy Cobbley
life safety passed.

Phone #: 2085591460 >> Inspection requested via mobile web by Aaron Carroll
FIRE-Final Inspection4/28/20204/29/20204/29/2020PFAIL
DetailsTroy Cobbley
Still need the emergency lights repaired for a life safety final.

Screened-ARMANDO Phone #: ###-####
FIRE-Final Inspection4/27/20204/28/20204/28/2020AFAIL
DetailsTroy Cobbley
Provide small documents, provide address as discussed, repair emergency lights as marked on the city approved plans.

*screened* Armando Phone #: ###-####
BLD-Ceiling Grid Inspection4/15/20204/16/20204/16/2020APASS
DetailsMike Jordan
*screened* Amando Phone #: ###-####
BLD-Energy code compliance3/10/20203/10/20203/10/2020PPASS
DetailsMike Jordan
Armando Phone #: ###-####
BLD-Framing/Rough-in3/6/20203/6/20203/6/2020PPASS
DetailsMike Jordan
armando Phone #: ###-####. Interior steel stud framed walls ok.
BLD-Other2/6/20202/6/20202/6/2020PDEFR
DetailsMike Jordan
roof before cover // Armando Phone #: ###-####. Ok to cover pending special inspection.
BLD-Framing/Rough-in1/22/20201/23/20201/23/2020APASS
DetailsMike Jordan
Armando Phone #: ###-####. Exterior sheathing ok. Verified sheeting is fire treated.
BLD-Framing/Rough-in1/17/20201/17/20201/17/2020PPASS
DetailsMike Jordan
armando Phone #: ###-####. Exterior steel stud walls and roof for compressor room ok to shaeet.
BLD-Other1/8/20201/9/20201/9/2020APART
DetailsMike Jordan
Armando- massory inspection Phone #: ###-####. Work in progress on south east corner of masonry wall at 8ft. to 12ft. elevation. Ok for grout pending special inspection.
BLD-Concrete12/13/201912/16/201912/16/2019ADEFR
DetailsMike Jordan
Aramado- pouring concrete please as early as possible Phone #: ###-####. Work in progress. Ok to grout pending special inspection.
BLD-Foundation11/27/201912/3/201912/3/2019PPASS
DetailsMike Jordan
rebar // Armando Phone #: ###-####. Interior slab on grade.
BLD-Footing11/18/201911/19/201911/19/2019APART
DetailsMike Jordan
Armando Phone #: ###-####. West stemwall, work in progress. Ok to place concrete pending special inspection.
BLD-Foundation11/14/201911/15/201911/18/2019APASS
DetailsDave Hannah
rebar // armondo Phone #: ###-####
BLD-Foundation11/6/201911/8/201911/8/2019PPEND
DetailsDave Hannah
rebar // Armando Phone #: ###-#### this is a ftg inspection looks good but not done spec inspection will sign off monday befor placement