Information based on query as of Sunday, May 5, 2024.
Permit Information
Permit NumberBLD19-03737
StatusIssued
Name WR GANN COMPANY
Site Address 205 W HIGHLAND VIEW DR
Project NameFery's Highland View Residence
Customer Number 
ePlanReviewYes
Description
**PLAN MODIFICATION 02/11/20 - updating grading and drainage due to landscaping changes. Updated ESC plans. JJN** **W.U.I. FOOTHILLS ZONE A CLASS "A" ROOF AND NON-COMBUSTIBLE EXTERIOR SIDING REQUIRED** **PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 6219 sq. ft., three story (first story 4486 sq. ft., second story 416 sq. ft. and basement is 1317 sq.ft) single family dwelling with 3 bedrooms, 3 and 2 powder bathrooms, approximately 570 sq. ft. of covered patio/porch and a 1993 sq. ft. attached garage per the approved plans and any notations. R-1B zoning and setbacks per planning. JJN ***Sprinklers are being provided***LGM A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.

Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Framing/Rough-in8/6/20208/6/20208/6/2020PPASS
DetailsTony Young
Bill - *//Screened*// Phone #: ###-####// ok to cover all
BLD-Energy code compliance7/27/20207/27/20207/27/2020PPART
DetailsTony Young
Screened- Bill Phone #: ###-####// ok except for fireplace area
BLD-Framing/Rough-in7/6/20207/6/20207/6/2020PPART
DetailsTony Young
Bill *screened* Phone #: ###-####// soffit base fire treated plywood ok,, fire treated cedar soffit materian noted on site// needs mechanical pass but ok to insulate unaffected areas// needs another ok on sprinklers// structural engineer of record has walked site and okayed as built
BLD-Aging Inspection6/4/20206/4/20206/8/2020 PASS
DetailsTony Young
BLD-Aging Inspection6/3/20206/3/20206/8/2020 PASS
DetailsTony Young
BLD-Other5/28/20205/29/20205/29/2020APASS
DetailsTony Young
soffit - screened // Bill Phone #: ###-####
BLD-Conference5/27/20205/28/20205/28/2020APASS
DetailsTony Young
screened - siding and fireplace hearth // Bill Phone #: ###-####,, ?s on clearence on epay wood,, ok,, fireplace,, needs specs or ok from manf.
BLD-Conference5/12/20205/13/20205/13/2020APASS
DetailsTony Young
screened // handrails and landscaping - Bill Phone #: ###-####,, no guardrail needed out along boulder landscape wall
BLD-Conference4/29/20204/29/20204/29/2020PPASS
DetailsTony Young
Walt Gann; Phone #: ###-####,, will use a commercial grade painted ok exterior cover
BLD-Wall Bracing4/16/20204/17/20204/17/2020APEND
DetailsBrandon Shaw
See plans for missing hold down, marked in red...
See shear schedule for walls requiring /spacing of A-35 clips...
To be installed before framing f\rough-in...
BLD-Final1/29/20201/31/20201/31/2020ACANC
DetailsDave Hannah
Donna Phone #: ###-####
BLD-Foundation1/21/20201/21/20201/21/2020PPART
DetailsTony Young
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro // retaining walls on the west side ok,, work in progress
BLD-Foundation1/10/20201/13/20201/13/2020APASS
DetailsBrandon Shaw
Work in progress...
Frost protection is reqired...
BLD-Foundation1/9/20201/10/20201/10/2020APART
DetailsTony Young
Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro// mostly covered with concrete blankets.. will pour on monday
BLD-Footing12/10/201912/11/201912/11/2019APASS
DetailsDave Hannah
Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro
BLD-Footing12/10/201912/10/201912/10/2019PCANC
DetailsBrandon Shaw
As late as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro Inspection cancelled via mobile web on Tuesday, December 10, 2019.