Information based on query as of Sunday, May 5, 2024.
Permit Information
Permit NumberELE16-02702
StatusIssued
Name ARTEAGA ALFREDO A
Site Address 2710 W WYMER ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Homeowner Online - Alteration or Repair: Adding 200 amp panel to garage
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
ELE-Aging Inspection7/6/20207/6/20207/6/2020 PEND
DetailsDaryl DeGrange
This permit is still open with the City of Boise. Please call 208 ###-#### with progress report or any questions. If your job is complete, Please schedule an final inspection online, pdsonline.cityofboise.org Thank You!
ELE-Aging Inspection4/6/20204/6/20204/6/2020 DONE
DetailsDaryl DeGrange
Pursuant of contacting aging permit applicants is on hold until required social distancing has been removed
ELE-Aging Inspection10/23/201910/23/201910/24/2019 DONE
DetailsEric Story
Still waiting on owner
ELE-Aging Inspection6/17/20196/17/20196/18/2019 DONE
DetailsEric Story
Owner will schedule for final as work is complete
Final8/22/20168/23/20168/23/2016ANR
DetailsRock A. Hudson
i installed 2nd ground rod and Noalox compound. Please come as soon as possible. Idaho power is coming on 8/23 to connect transformer to panel. Thank you for your time Phone #: ###-####
Inspection requested via web by alfredo arteaga Needed p/s inspection
Service added to garage. All branch circuits have not been pulled yet.
Permanent Service8/23/20168/23/20168/23/2016PPASS
DetailsRock A. Hudson
i installed 2nd ground rod and Noalox compound. Please come as soon as possible. Idaho power is coming on 8/23 to connect transformer to panel. Thank you for your time Phone #: ###-#### Inspection requested via web by alfredo arteaga p/s o/h n ok
Final8/18/20168/22/20168/22/2016ACANC
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by alfredo arteaga
Needed permanent service inspection
Permanent Service8/22/20168/22/20168/22/2016PFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by alfredo arteaga
110.14- Aluminum conductors shal be coated with a oxide inhibitor when terminated.
250.53(A)(1)- Where rod is used as grounding electrode system it shall be supplemented by an additional rod.