Permit Information
Permit NumberELE17-02862
StatusFinaled
Name LEA ELECTRIC LLC
Site Address 505 W IDAHO ST
Project Name 
Customer Number3724 BLD16-02007 & 2008
ePlanReviewNo
Description
****2 BLD permits for this project***New: Complete electrical installation including underground, conduit, raceways, boxes, wiring, gear, panels, switches, lighting, lighting control, receptacles, fire alarm, and telecomm.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/4/20192/4/20192/4/2019APASS
DetailsRock A. Hudson
TCO on 5TH floor deck and sign off on final Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Oirginal permit not provided, signed all TCO sheets for final. Final ok
Final12/18/201812/18/201812/18/2018PPART
DetailsRock A. Hudson
TCO Plaza park area front of building Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Phase 4 TCO ok
Final11/30/201811/30/201811/30/2018APART
DetailsRock A. Hudson
Units 110 , 111 , 112 Phone #: ###-#### Inspection requested via web by Tom Betty
Phase 2- level 1 loft units 110 thru 115 TCO ok.
Phase 5- Garage TCO ok.
Final11/27/201811/27/201811/27/2018ANR
DetailsRock A. Hudson
Units 110 , 111 , 112 , 113 , 114 , 115 and Garage Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
113, 114, 115 checked ok, 110, 111, 112 no access, a barrier shall be in place in garage for feeders.
Final11/14/201811/14/201811/14/2018APART
DetailsRock A. Hudson
Reinspect roof,arc fault 313 ,Inspect first level parking condensors Phone #: ###-#### Inspection requested via web by Tom Betty
No card on site... it had been taken to ACHD. 213 had bad AFCI- ok, trash room fan- ok, 1st fl. wire for hand dryer blanked-ok.
Phase 1 TCO ok
Final11/12/201811/13/201811/13/2018AFAIL
DetailsDaryl DeGrange
All 2ND Floor storage, comm rm , hallway and units 201,202,203,204,205,206,207,208,209,210,211,212,213,214,215,216,217,218,219.,Stairwell#1 and Stairwell#2,1st Floor Lobby,Bathrm, Trash rm,Bike rm,Sprinkler riser rm, mail rm, Move in rm and roof top condenser units Phone #: 573-
1573 Inspection requested via web by Tom Betty All corrections listed are for roof top mini split systems.
330.6- All connectors used on coated MC cable shall be listed and identified for use.
725.3(J)- Bushings shall be provided and properly installed for all wiring marked class 2R.
725.124- Class 2 power sources shall be clearly marked. Measured 208 volts on terminal with class 2 wiring connected.
As per Daryl DeGrange wiring marked class 3 ok due to documentation found on Southwire web site deffinition and explanation.
Final11/8/201811/8/201811/8/2018APART
DetailsRock A. Hudson
3rd floor Hall,Storage , comm rm and Units 301 , 302 , 303 , 304 , 305 , 306 , 307 , 308 , 309 , 310 , 311 , 312 , 313 , 314 , 315 , 316 , 317 , 318 , 319 Call Craig Phone #: ###-#### Inspection
requested via web by Tom Betty
301- 250.52- walls 24" and wider shall have a receptacle outlet installed in bedroom.
309- 210.52(A)- Receptacles required by this article shall be energized continuously. Permitted switched receptacles shall only switch 1/2 of receptacle.
Corridor comm room- 408.4- Circuit directory shall be complete for panel in this room.
302, 303, 304, 305, 306, 307, 308, 310, 311, 312, 313, 314, 315, 316, 317, 317, 318, 319, corridor and storage rooms TCO ok
Electrical Rough-In11/6/201811/6/201811/6/2018PPASS
DetailsRock A. Hudson
Some underground on east end of building,Hello Rock missed calling in for an AM but it is ready if you could make it early Thanks Craig Phone #: ###-#### Inspection requested via web by Tom Betty
rough in ok cover
Final10/31/201811/1/201811/1/2018APART
DetailsRock A. Hudson
reinspect units 504 , 505 506 ,508 , 510 , 511 , 513 and inspect 4th floor storage, comm and units 401 , 402 , 403 , 404 , 405 , 406 , 407 , 408 , 409 , 410 , 411 , 412 , 413 , 414 , 415 , 416 , 417 , 418 , 419 Phone #: ###-#### Inspection requested via web by Tom Betty
Storage damper wiring 12-2 MC not wired, missing covers in corridor, 402, 403, 405.
All others noted TCO ok
Final10/29/201810/31/201810/31/2018APART
DetailsRock A. Hudson
Finals for units on 5th floor ,hallway and storage rooms, Units 502 thru 519 call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
314.20- Interior of boxes shall not be exposed to combustible materials. 504 disposal located pert behind cabinet divider. 506 microwave receptacle located part behind divider.
110.3- All siring shall be terminated as per drawing and manufacturers instructions. 505 3 bed receptacles not working, 508,510,513 all have 2 single pole switches controlling living room lights, 511 open ground in living room receptacle.
502, 503, 507, 509, 512, 514, 515, 516, 517, 518, 519 rooms only TCO ok
Electrical Rough-In10/30/201810/30/201810/30/2018APASS
DetailsRock A. Hudson
Drop ceiling office and ground work front of building Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
North central underground and office drop lid rough in ok cover
Electrical Rough-In10/24/201810/24/201810/24/2018PPASS
DetailsRock A. Hudson
Underground conduit for street pole lighting Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Informed to be sure to call public works about street light installation.
Idaho street west pole base and underground rough in ok cover.
Electrical Rough-In10/23/201810/23/201810/23/2018PPASS
DetailsRock A. Hudson
First floor drop ceilings Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty Level 1 mail bax hall, bath, lobby hardlid rough in ok cover
Electrical Rough-In10/23/201810/23/201810/23/2018ACANC
DetailsRock A. Hudson
First floor drop ceilings Call Craig Phone #: ###-#### >> Inspection requested via web by Tom Betty Inspection cancelled from web by: Tom Betty
Electrical Rough-In10/15/201810/15/201810/15/2018APASS
DetailsRock A. Hudson
Garage ceiling for insulation Phone #: ###-#### Inspection requested via web by Tom Betty
NEC 330.30 and 110.27- MC cable shall not be installed where subject to physical damage. Just outside meter area is a lower section of ceiling where MC located between 6'6" and 7'. If located below striker height this area shall be protected from damage from traffic and pedestrian traffic by fencing off.
Area of ceiling in parking garage ok to insulate.
Electrical Rough-In10/9/201810/9/201810/9/2018APASS
DetailsRock A. Hudson
drop ceiling 112 Phone #: ###-#### Inspection requested via web by Tom Betty
Room noted drop lids rough in ok cover
Electrical Rough-In10/3/201810/5/201810/5/2018PPASS
DetailsRock A. Hudson
Drop ceilings 110 , 111 , 112 , 113 . 114 , 115 Phone #: ###-#### Inspection requested via web by Tom Betty
112 not ready, rest noted drop lids rough in ok cover
Permanent Service9/21/20189/21/20189/21/2018PPASS
DetailsRock A. Hudson
Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
86,448 AIC value provided on print.
p/s u/g n ok
Electrical Rough-In8/22/20188/22/20188/22/2018PPASS
DetailsRock A. Hudson
Drop ceiling 201 ,202 , 203 , 204 , 205 , 206 , 207 , 208 , 209 , 210 , 211 , 212 ,213 , 214 , 215 , 216 , 217 , 218 , 219 , hallways , storage rooms and comm room mezzanine Phone #: ###-####
Inspection requested via web by Tom Betty
Fire caulking not complete, Areas noted drop lids rough in ok cover
Electrical Rough-In8/17/20188/17/20188/17/2018APASS
DetailsRock A. Hudson
Lobby,storage , bike room , trash room . etc rest of 1st floor
Phone #: ###-#### Inspection requested via web by Tom Betty
Areas noted plus mail rm, and move in room, vanilla TI space rough in ok cover
Electrical Rough-In8/10/20188/10/20188/10/2018APASS
DetailsEric Story
Drop ceilings 301 ,302 , 303, 304 , 305 , 306 , 307 , 308 , 309 ,310 , 311 , 312 , 313 , 314 , 315 , 316 , 317 , 318 , 319 , storage and 3rd floor hallway call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Units 301-319 and hallway drop ceilings as well as storage ok to cover
Electrical Rough-In8/7/20188/8/20188/8/2018APASS
DetailsRock A. Hudson
drop ceiling 401 sorry Rock this is the only unit they need inspected they finally put fan in bath room just hate to waste your time on one unit Phone #: ###-#### Inspection requested via web by Tom Betty
Room noted drop lids rough in ok cover
Electrical Rough-In8/1/20188/1/20188/1/2018PPASS
DetailsRock A. Hudson
Drop ceilings hallway 4th floor Phone #: ###-#### Inspection requested via web by Tom Betty
Corridor and storage room drop lids rough in ok cover.
Electrical Rough-In7/30/20187/30/20187/30/2018APASS
DetailsRock A. Hudson
5TH floor hallway drop ceilings Phone #: ###-#### Inspection requested via web by Tom Betty
Misc storage rooms to have surface mount luminaires. OK
Corridor drop lids rough in ok cover.
Electrical Rough-In7/26/20187/26/20187/27/2018PPASS
DetailsRock A. Hudson
Unit 113 and drop ceilings 401 , 409 , 411 , 412 , 413 , 414 , 415 , 416 Phone #: ###-#### Inspection requested via web by Tom Betty
401 not ready,409 thru 416 drop lids, unit 113 rough in ok cover
Electrical Rough-In7/25/20187/25/20187/25/2018PPASS
DetailsRock A. Hudson
units 115 , 110 , 111 and dog wash Phone #: ###-#### Inspection requested via web by Tom Betty
Rooms noted rough in ok cover
Electrical Rough-In7/23/20187/23/20187/23/2018PPASS
DetailsRock A. Hudson
Drop ceilings 401, 402 , 403 , 404 , 405 , 406 , 407 , 408 , 410 , 417 ,418 and Phone #: ###-#### Inspection requested via web by Tom Betty
401, 410 not ready, rest of rooms noted and added 419 drop lid rough in ok cover
Electrical Rough-In7/20/20187/20/20187/20/2018PPASS
DetailsRock A. Hudson
units 113 , 114 and stairs #1 and #2 , 2nd and first floor Phone #: ###-#### Inspection requested via web by Tom Betty Rooms and areas noted rough in ok cover
Electrical Rough-In7/16/20187/16/20187/16/2018PPASS
DetailsRock A. Hudson
Units 212 , 213 , 214 2nd floor hallway ,storage and drop ceilings 512 , 513 , 514 , 515 , 516 Phone #: ###-#### Inspection requested via web by Tom Betty
Areas and rooms as noted rough in ok cover
Electrical Rough-In7/16/20187/16/20187/16/2018PCANC
DetailsRock A. Hudson
Units 212 , 213 , 214 , drop ceilings 512 , 513 , 514 , 515 ,516 Call Craig Phone #: ###-#### >> Inspection requested via web by Tom Betty Inspection cancelled from web by: Tom Betty
Electrical Rough-In7/13/20187/13/20187/13/2018PPASS
DetailsRock A. Hudson
units 209 , 210 , 211 , 216 , 215 and drop ceilings 510 , 511 Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Discussed location of HVAC disconnects for mini split unit located 10' above grade. Fused disconnects require minimum work space due to servicing fuses. Non fused disconnects do not require work space.
Rooms and hard lids noted rough in ok cover
Electrical Rough-In7/12/20187/12/20187/12/2018APASS
DetailsRock A. Hudson
units 205 , 206 , 207 , 208 , 217 drop ceilings 502 , 503 , 504 , 505 , 506 , 507 , 508 , 509 , 517 , 518 , 519 Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Informed elevator contractor needs city permit to continue installation.
As noted rough in ok cover
Electrical Rough-In7/10/20187/10/20187/10/2018APART
DetailsRock A. Hudson
units 201 , 202 , 203 , 204 , 205 , 219 , 218 ,313 , 314 , 315 call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
205 not ready, rest of rooms noted rough in ok cover
Electrical Rough-In7/6/20187/6/20187/6/2018APASS
DetailsRock A. Hudson
units 309 , 310 , 311 , 312 , 316 , hallway , and storage Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty Rooms and areas noted rough in ok cover
Electrical Rough-In7/3/20187/3/20187/3/2018APASS
DetailsRock A. Hudson
301 , 302 , 303 , 304 , 305 , 306 , 307 , 308 , 317 , 318 , 319 call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Rooms noted rough in ok cover
Electrical Rough-In6/27/20186/27/20186/27/2018APASS
DetailsRock A. Hudson
Units 412 , 413 ,414 , 415 Phone #: ###-#### Inspection requested via web by Tom Betty Rooms noted rough in ok cover.
Electrical Rough-In6/26/20186/26/20186/26/2018APASS
DetailsRock A. Hudson
Units 409 , 410 , 411 , 416 and stairs 4th floor Phone #: ###-#### Inspection requested via web by Tom Betty
Rooms noted rough in ok cover
Electrical Rough-In6/22/20186/22/20186/22/2018APASS
DetailsRock A. Hudson
Units 404 , 408 ,Hallway , storage ,comm rm and re inspect 405 , 406 Phone #: ###-#### Inspection requested via web by Tom Betty
Informed next trip will be turned down for make up not totally rolled in boxes subject to damage, stapling on edge, installation not in a neat workman like manner.
Rooms noted rough in ok cover
Electrical Rough-In6/21/20186/21/20186/21/2018APART
DetailsRock A. Hudson
units 401 , 402 , 403 , 405 , 406 , 407 , 419 , 418 and 419 Phone #: ###-#### Inspection requested via web by Tom Betty 110.14(B)- All equipment grounding conductors shall be spliced for inspection at rough in inspection. Splicing shall be completed by using a listed connector.
405 and 406 switches, equipment grounds twisted together with no connector, receptacle locations just rolled in boxes.
401, 402, 403, 407, 417, 418, 419 only rough in ok cover
Electrical Rough-In6/14/20186/14/20186/14/2018APASS
DetailsRock A. Hudson
Units 513 , 514 and 5th floor stairs #1 and #2 Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty Areas noted and elevator dog house stub rough in ok cover. Left green tag on electrical office door.
Electrical Rough-In6/13/20186/13/20186/13/2018APASS
DetailsRock A. Hudson
Units 502 , 503 , 504 , 512 , 515 , 516 , 517 , 518 , 519 , elevator equipment room , trash rm , storage rms and 5th floor hallway call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Areas noted walls and fire lids rough in ok cover
Electrical Rough-In6/7/20186/7/20186/7/2018APASS
DetailsRock A. Hudson
Units 508 , 509 , 510 , 511 Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Added 505, 506, 507 and other listed rough in ok cover
Electrical Rough-In5/24/20185/24/20185/24/2018APASS
DetailsRock A. Hudson
Parapet wall on roof Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Parapet UF run between stubs due to roof not dryed in yet. rough in ok cover
Electrical Rough-In12/7/201712/8/201712/8/2017APASS
DetailsRock A. Hudson
PT deck concrete pour call craig Phone #: ###-#### Inspection requested via web by Tom Betty
Discussed the use of NM cable for floors 1 thru 5 which are wood construction, type 3, 4, and 5 construction NM cables permitted as long as behind 15 minute barrier or greater and not above suspended ceilings.
PT deck east 1/2 pour rough in ok cover.
Electrical Rough-In11/21/201711/22/201711/22/2017APART
DetailsDaryl DeGrange
Look at PT deck rough-in Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty Rough-in ok cover west half
Electrical Rough-In10/10/201710/10/201710/10/2017PPASS
DetailsRock A. Hudson
Ground work and east wall Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Lower level underground and east wall rough in ok cover
Electrical Rough-In9/19/20179/20/20179/20/2017APASS
DetailsRock A. Hudson
Basement poured concrete walls south and stairwell #1 Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty Area noted rough in ok cover
Electrical Rough-In9/7/20179/8/20179/8/2017APASS
DetailsRock A. Hudson
UFER grounding Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
Concrete encased electrode and N.W. basement wall pour rough in ok cover.