Description |
[Firenza Pirzza TI] - Quick Permit
ADD/RELOCATE SPRINKLERS THROUGHOUT THE TI SPACES PER NFPA 13 2016 FOR LIGHT HAZARD. EXISTING CPVC LINES AND MAINS TO REMAIN IN PLACE.
[BLD18-02510]
The fire sprinkler system is used for high rise and for fire area. To convert a 2,644 square foot area formerly used as an office into a pizza restaurant. The total area of the restaurant will be 3,569 square feet (2,644 square feet interior and 925 square feet exterior patios). Work is to include interior nonbearing walls, wall furring, half-height walls, interior doors, two new exterior overhead glass doors with tube steel beams and columns to resist out-of-plane lateral loads, guard rails, dining booths, tables and chairs, fixed benches, drink dispensers, a 95 square foot walk-in cooler, kitchen equipment, a gas fired pizza oven that weighs about 7,000 pounds, a Type I grease hood and horizontal duct system, a stacked washer and dryer, suspended acoustical ceilings, gypsum board ceilings and soffits, millwork, and finishes. Special Inspection is required for welding and for anchors post-installed in hardened concrete. The toilet rooms on the 1st story were upgraded to be accessible to the disabled under permit BLD18-01334. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
|