Final | 12/12/2018 | 12/12/2018 | 12/12/2018 | P | PASS |
Brian Scoles
|
|
|
MEC AND FIREPL GARage CODE 7373 Phone #: ###-#### Inspection requested via web by Oleg Chervak
|
Final | 12/11/2018 | 12/11/2018 | 12/11/2018 | P | FAIL |
Brian Scoles
|
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- needs combustion air registers cut in doors in garage- no air balance they were finishing
|
Rough-in | 10/9/2018 | 10/9/2018 | 10/9/2018 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- Hvac R/I ok
|
Rough-in | 10/9/2018 | 10/9/2018 | 10/9/2018 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- fireplace R/I ok
|
Rough-in | 10/8/2018 | 10/9/2018 | 10/9/2018 | A | FAIL |
Brian Scoles
|
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- insulation shield on water heater b vent needs to extend to roof pitch- crawl needs completed- need to seal dryer duct to termination box- R/A for bedroom 2 & 3 not per man j needs to tie into 18" round ducting not at register can off 14" round- reinspection fee issued for ongoing issues on new construction R/Is- left correction notice front entry window
|
Pressure Test | 10/8/2018 | 10/9/2018 | 10/9/2018 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
|