Final | 5/29/2019 | 5/30/2019 | 5/30/2019 | P | PASS |
Jack Reynolds
|
|
|
garage code 1234 Phone #: ###-#### Inspection requested via web by Terek Worley - final ok
|
Conference | 5/29/2019 | 5/30/2019 | 5/30/2019 | P | PASS |
Jack Reynolds
|
|
|
witness Duct blast test please Phone #: ###-#### Inspection requested via web by Terek Worley - duct blast ok
|
Final | 2/11/2019 | 2/12/2019 | 2/12/2019 | P | FAIL |
Jack Reynolds
|
|
|
garage code 1234 Phone #: ###-#### Inspection requested via web by Terek Worley - need to witness duct blast test - need access to furnace in attic
|
Rough-in | 1/7/2019 | 1/7/2019 | 1/7/2019 | P | CANC |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley
|
Rough-in | 12/14/2018 | 12/17/2018 | 12/17/2018 | A | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley - R/I ok
|
Rough-in | 12/13/2018 | 12/14/2018 | 12/14/2018 | A | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley - two range hoods will be under 400 cfm each hood has a max 190 cfm - Man J doesnt match what is installed in home. - the Man J shows gas furnace and there is a electric furnace installed
|
Rough-in | 12/4/2018 | 12/5/2018 | 12/5/2018 | A | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley - need approved man J onsite - two range hoods being installed either need to bring fresh air into space or provide manufacture specs showing hoods will be under 400 cfm - need to access furnace when approved man J shows up onsite
|
Pressure Test | 12/4/2018 | 12/5/2018 | 12/5/2018 | A | CANC |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley
|
Rough-in | 11/20/2018 | 11/26/2018 | 11/26/2018 | A | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley - need approved Man J. onsite - fresh air needs to come off return at furnace not return register can - if range hood is over 400 cfm it will need make- up air. Looks like two hoods are being installed
|
Pressure Test | 11/20/2018 | 11/26/2018 | 11/26/2018 | A | CANC |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley- not sure what needs a pressure test. looks like furnace is electric and i dont see a gas line anywhere
|