BLD-Final | 10/19/2001 | 10/22/2001 | 10/22/2001 | A | PASS |
Tony Young
|
|
|
###-#### SCOTT STRATA SENT A LETTER TERRY RECORDS.
|
BLD-Grading Inspection | 10/22/2001 | 10/22/2001 | 10/22/2001 | | PASS |
Rita DeYoung
|
|
|
Final grading and drainage isa approved.
|
DOC - Permit Finaled | 10/22/2001 | 10/22/2001 | 10/22/2001 | P | PASS |
Tony Young
|
|
|
Finaled by inspector at 10/22/2001 11:50:56 AM
|
BLD-Final | 10/11/2001 | 10/12/2001 | 10/12/2001 | P | NR |
Russ Owen
|
|
|
###-####. No inspection can be done untill Hillside requirements have been satisfied,left c/n to contact Terry Records. NO INSPECTION DONE THIS DAY. NOT READY. 10/12/2001 2:11:36 PM
|
Ready Permit EXTENDED | | | 10/11/2001 | | DONE |
|
|
|
extend permit per tony young/work still in progress per builder/mls
|
Reopen Permit (ISS) | | | 10/11/2001 | | DONE |
|
|
|
per tony young-work still in progress/mls
|
BLD-Framing/Rough-in | 8/23/2000 | 8/24/2000 | 8/24/2000 | A | PART |
Tony Young
|
|
|
###-#### late pm
still need energy report 8/24/2000 4:42:23 PM
|
BLD-Framing/Rough-in | 8/14/2000 | 8/15/2000 | 8/15/2000 | A | PART |
|
|
|
Scheduled by a contractor via Hello! on 08/14/2000 at 14:59:26. Contact: . made ok to insulate only, met with 325 and 415 on project with ctr rep, john the framer and Keith Jones, the eng of record. questions were raised about the hold down straps nailed and hidden under the sheathing without inspection of same, also waiting for resonnse from the truss eng on the use of 21/2 " nails vs 3" nails called out on the eng specifically. 8/15/00 11:00:33 AM
|
BLD-Framing/Rough-in | 8/15/2000 | 8/15/2000 | 8/15/2000 | A | PART |
Tony Young
|
|
|
Scheduled by Inspector: 415 On 8/15/2000
ok to insulate, waiting for shear wall engineering fix from Keith ,,, do not side. 8/15/2000 10:19:15 AM
|
BLD-Framing/Rough-in | 8/11/2000 | 8/14/2000 | 8/14/2000 | A | FAIL |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 08/11/2000 at 13:37:22. Contact: .
C/N left to have engineer verify all engineering and to recall frame inspection when engineer will be on site to go over other matters 8/14/2000 12:34:01 PM
|
BLD-Framing/Rough-in | 6/13/2000 | 6/13/2000 | 6/13/2000 | P | PASS |
Russ Owen
|
|
|
wall insp Rick ###-#### Garage walls ok 6/14/00 8:50:01 AM
|
BLD-Foundation | 6/8/2000 | 6/8/2000 | 6/8/2000 | P | PASS |
Russ Owen
|
|
|
rick ###-#### foundation wall Garage walls left 6/13/00 10:07:42 AM
|
BLD-Footing | 5/31/2000 | 6/1/2000 | 6/1/2000 | P | FAIL |
Russ Owen
|
|
|
rick ###-#### Not ready, ok by Terry Records for soils recall footing insp. 6/5/00 10:20:30 AM
|
Issue PAID IN FULL permit | | | 5/18/2000 | | DONE |
|
|
|
|
Plan assigned to (DJO) | 5/11/2000 | 5/11/2000 | 5/16/2000 | | PASS |
Dan Overy
|
|
|
5/16/2000 09:26:47 AJC - activity updated through activity BLDA022 from case BLD00-00923.
|
Plan assigned to (DJO) | 5/10/2000 | 5/10/2000 | 5/16/2000 | | PASS |
Dan Overy
|
|
|
5/16/2000 09:26:47 AJC - activity updated through activity BLDA022 from case BLD00-00923.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/16/2000 | | DONE |
|
|
|
as per Dan Overy he forgot to put this action in so I am for him....
|
Inspection Record Card- Bld | | | 5/16/2000 | | DONE |
|
|
|
|
Telephone call | | | 5/16/2000 | | DONE |
|
|
|
called ###-#### Woolston Const permit ready for pickup
|
Print Pending Permit.LaserJet4 | | | 5/11/2000 | | DONE |
|
|
|
|
Plan Review Report | | | 5/11/2000 | | DONE |
|
|
|
|
Plans ACCEPTED BY PLAN CHECK | | | 5/11/2000 | | |
|
|
|
|
Plans ACCEPTED BY PLAN CHECK | | | 5/10/2000 | | |
|
|
|
|
Routing - PLANNING | 4/19/2000 | 4/19/2000 | 4/19/2000 | | DONE |
|
|
|
|
Routing - PUBLIC WORKS | 4/7/2000 | 4/7/2000 | 4/18/2000 | | DONE |
|
|
|
|
Routing - PUBLIC WORKS GRADING | 4/7/2000 | 4/7/2000 | 4/18/2000 | | PASS |
Rita DeYoung
|
|
|
took to terry records 4/7/00. Approved as Category 3. Comply with requirements of soils report by Strata Geotechnical Engineers and conditions of approval contained in letter from Public Works attached to the plans.
|
Application received | | | 4/7/2000 | | |
|
|
|
|
Routing - PLAN CHECK | 4/19/2000 | 4/19/2000 | | | PEND |
|
|
|
|
Plan Reviewer's activity | | | | | |
|
|
|
have called designer and engineer about lack of engineered foundation plans. being taken care of. 5-10-2000
|
Pending Assignment by DJO | 4/7/2000 | | | | PEND |
Dan Overy
|
|
|
|
Plan Reviewer's activity | | | | | |
|
|
|
engineered foundation plans, along with sections, calculations, holdown locations by licensed Idaho engineer req.
|