Case Summary (BLD) | | | 4/1/2015 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 9/4/2013 | | DONE |
|
|
|
|
BLD-Final | 5/8/2001 | 5/9/2001 | 5/9/2001 | A | PASS |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 05/08/2001 at 17:13:25. Contact: ###-####. C. of C. #20421 issued 5/9/2001 10:39:50 AM
|
DOC - Permit Finaled | 5/9/2001 | 5/9/2001 | 5/9/2001 | A | PASS |
Steven Webb
|
|
|
Finaled by inspector at 5/9/2001 10:39:56 AM
|
BLD-Final | 5/4/2001 | 5/7/2001 | 5/7/2001 | A | FAIL |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 05/04/2001 at 11:36:03. Contact: ###-####. C/n issued--handrail off deck & guardrail needs additional fastening to strenghten. 5/7/2001 8:27:02 AM
|
CHANGE STATUS TO (ISS) | | | 5/4/2001 | | DONE |
|
|
|
|
BLD-Energy code compliance | 8/18/2000 | 8/21/2000 | 8/21/2000 | A | PASS |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 08/18/2000 at 18:30:33. Contact: ###-####.
|
BLD-Energy code compliance | 8/18/2000 | 8/18/2000 | 8/18/2000 | P | FAIL |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 08/18/2000 at 09:46:34. Contact: ###-####. missing vapor barrier. 8/21/2000 8:53:59 AM
|
BLD-Framing/Rough-in | 8/18/2000 | 8/18/2000 | 8/18/2000 | P | PASS |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 08/18/2000 at 09:47:21. Contact: ###-####.
|
BLD-Framing/Rough-in | 8/16/2000 | 8/17/2000 | 8/17/2000 | A | FAIL |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 08/16/2000 at 18:21:29. Contact: ###-####.
|
BLD-Framing/Rough-in | 8/17/2000 | 8/17/2000 | 8/17/2000 | P | FAIL |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 8/17/2000 c/n issued, russ area. straps, hand stack framing, cripple walls, etc.
|
BLD-Other | 8/10/2000 | 8/10/2000 | 8/10/2000 | P | PART |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 08/10/2000 at 08:10:39. Contact: ###-####. Nail up hd's at rear. 8/11/2000 9:23:59 AM
|
BLD-Framing/Rough-in | 8/8/2000 | 8/9/2000 | 8/9/2000 | P | FAIL |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 08/08/2000 at 20:51:40. Contact: ###-####. 8/9/2000 3:12:51 PM
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/30/2000 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 6/30/2000 | | DONE |
|
|
|
|
Telephone call | | | 6/30/2000 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 6/30/2000 | | DONE |
|
|
|
|
Plan assigned to (SAM) | 6/28/2000 | | 6/30/2000 | | PASS |
Steve Munroe
|
|
|
6/30/2000 08:44:18 SAM - activity updated through activity BLDA022 from case BLD00-01666.
|
BLD-Footing | 6/29/2000 | 6/29/2000 | 6/29/2000 | P | PART |
Russ Owen
|
|
|
early start okay ###-#### early start appears ok 7/3/00 8:38:04 AM
|
Pending Assignment by DJO | 6/9/2000 | | 6/28/2000 | | DONE |
Dan Overy
|
|
|
|
Routing - PUBLIC WORKS | 6/9/2000 | 6/9/2000 | 6/12/2000 | | PASS |
|
|
|
|
Routing - PLANNING | 6/9/2000 | 6/9/2000 | 6/12/2000 | | PASS |
|
|
|
|
Application received | | | 6/9/2000 | | |
|
|
|
|
Routing - PLAN CHECK | 6/12/2000 | 6/12/2000 | | | PEND |
|
|
|
|
Early Start Permit | | | | | PEND |
|
|
|
|
Plan Reviewer's activity | | | | | PEND |
|
|
|
6/29/00 15:05 Called and talked to Darin at AHJ and then called and talked to Alan with HSA. Alan said to go ahead and issue plans with red-lining. He will also let me know if we are going to run the shear on the inside of the garage instead of the outside.
|
Print Pending Permit.LaserJet4 | | | | | |
|
|
|
|
Plan Review Report | | | | | |
|
|
|
|