Permit Information
Permit NumberBLD00-01721
StatusFinaled
Name ST LUKES
Site Address 190 E BANNOCK ST
Project NameST LUKES-CENTRAL WING
Customer Number 
ePlanReviewNo
Description
ST LUKES-CENTRAL WING-1ST FLOOR (CENTRAL DISPATCH). To remodel an existing 313 sq.ft. room used as a Staff Lounge to become office for Central Dispatch, per approved plans on file. Work to include removal of existing interior furnishings & wall / floor finishes; remove existing light fixture,s & HVAC diffussers; install new fixture's & HVAC grills / diffusers in existing suspended ceiling; addinterio wall & floor finsihes; new cabinetry / millwork; install associated electrical & mechanical upgrade to serve the new use; provide new opening into non-rated hallway as vision panel with security drop off station; add new rough in plumbing for future sink; and new short wall section, all per approved plans. NOTE: This building is fully fire sprinklered and has a fire alarm system. CONDITION OF PERMIT ISSUANCE REQUIRES FIELD FIRE CODE INSPECTOR TO VERIFY CODE ITEM COMPLIANCE. (P.C.#464-00)/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled4/24/20034/24/20034/24/2003PPASS
DetailsCarl Dependahl
Finaled by inspector at 4/24/2003 3:53:53 PM
BLD-Aging Inspection4/21/20034/21/20034/21/2003 PASS
DetailsCarl Dependahl
Inspection Record Card- Bld  2/21/2003 DONE
Case Summary (BLD)  2/7/2003  
Fee Review-notes6/15/20006/15/20009/17/2001 DONE
FIRE-Final Inspection12/7/200012/8/200012/8/2000APASS
DetailsRick Jackson
Scheduled by a contractor via Hello! on 12/07/2000 at 10:43:46. Contact: ###-####.
BLD-Final12/7/200012/8/200012/8/2000PFAIL
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 12/07/2000 at 10:44:28. Contact: ###-####. need elec final 12/8/2000 4:18:44 PM
FIRE-Final Inspection11/14/200011/15/200011/15/2000AFAIL
DetailsRick Jackson
Scheduled by a contractor via Hello! on 11/14/2000 at 15:21:29. Contact: ###-####. //// need sprinkler head in closet and smoke detector; penetrations in 2 hr wall; need 2 hr wall completed at non-rated hall; door not latching at hallway 11/15/2000 10:32:40 AM
BLD-Final11/14/200011/15/200011/15/2000ANR
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 11/14/2000 at 15:22:05. Contact: ###-####...recall when ready...fire??? 11/15/2000 4:06:07 PM
BLD-Conference7/14/20007/14/20007/14/2000APASS
Details
Added by Inspector: 338 On 7/14/2000 walk through in progress
Issue & PRINT permit  7/6/2000 DONE
CHANGE STATUS TO (ISS)  7/6/2000 DONE
Print Occupancy Form  7/3/2000 DONE
Inspection Record Card- Bld  7/3/2000 DONE
Plan assigned to (DRS)6/16/2000 6/30/2000 PASS
DetailsDan Stuart
6/30/2000 16:51:10 DRS - activity updated through activity BLDA022 from case BLD00-01721.
Routing - PLAN CHECK6/19/2000 6/30/2000 PASS
No resubmittals required. Routing to Fire Code plan analyst for review. Okay by Sam Rogers to issue with condition fire code compliance be verified in field as condition of permit.Routing to permit desk for issuance.
Routing - FIRE  6/30/2000 PASS
REVIEWED PLANS WITH SAM ROGERS. NO CHANGES TO SPRINKLER SYSTEM OR OTHER FIRE/LIFE SAFETY ITEMS INDICATED ON PLAN REMODEL. sAMM APPROVED ISSUANCE OF PERMIT WITHOUT ROUTING TO HIM WITH CONDITION THAT FIRE CODE COMPLIANCE ITEMS BE VERIFIED IN FIELD BY INSPECTOR. THIS IS NOTED IN PERMIT BODY.
PLANS/APPL TAKEN TO FRONT DESK  6/30/2000 PASS
ROUTED TO PERMIT DESK FOR ISSUANCE.
Routing - PUBLIC WORKS6/16/2000 6/19/2000 PASS
Plan routing begun/TENANTS  6/16/2000 DONE
Route to PUBLIC WORKS, PLAN CHECK and FIRE.
Pending Assignment by MYS6/16/2000 6/16/2000 DONE
DetailsMarlene Southard
Application received  6/15/2000  
Plans ACCEPTED BY PLAN TECH  6/15/2000 DONE
Received Certificate of Value  6/15/2000 DONE