Letter of compliance | | | 1/23/2001 | | DONE |
|
|
|
Letter of Compliance #21332 issued 1-23-01.
|
BLD-Final | 1/19/2001 | 1/22/2001 | 1/22/2001 | A | PASS |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 01/19/2001 at 11:27:03. Contact: ###-####. ok for l/c, card to bldr 1/22/2001 10:24:35 AM
|
BLD-Framing/Rough-in | 1/22/2001 | 1/22/2001 | 1/22/2001 | A | PASS |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 1/22/2001 10:25:50 AM beam installed at cant; wall opening ok per eng'g.
|
BLD-Final | 1/16/2001 | 1/17/2001 | 1/17/2001 | A | CANC |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 01/16/2001 at 18:26:34. Contact: ###-####.
|
BLD-Final | 1/12/2001 | 1/16/2001 | 1/16/2001 | P | CANC |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 01/12/2001 at 13:28:53. Contact: ###-####. called contractor no time left in day recall for insp 1/16/2001 4:53:15 PM
|
FIRE-Final Inspection | 1/8/2001 | 1/8/2001 | 1/9/2001 | P | PASS |
Rick Jackson
|
|
|
Scheduled by a contractor via Hello! on 01/08/2001 at 10:07:18. Contact: ###-####.
|
Inspection Record Card- Bld | | | 1/5/2001 | | DONE |
|
|
|
|
Print Occupancy Form | | | 1/5/2001 | | DONE |
|
|
|
|
Plan resubmittals received | | | 10/10/2000 | | DONE |
|
|
|
RECEIVED PLAN RESUBMITTALS FROM M PAC ENGINEERING FOR DAVID LIGHTFOOT. I WILL ENSURE THAT THESE PLANS ARE DELIVERED INTO DAVID LIGHTFOOTS HANDS. 10/10/00 DAR DAVID LIGHTFOOT LOOKED AT THE PLANS AND STATED HE NEED MOE INFORMATION AS THERE WAS NO LISTING WITH THIS SUBMITTAL AND THEN FORWARDED THEM TO CARL WESTFALL.. 10/11/00 DAR
|
Fee Review-notes | 6/15/2000 | 6/15/2000 | 9/7/2000 | | DONE |
|
|
|
ok
|
BLD-Conference | 8/18/2000 | 8/18/2000 | 8/18/2000 | A | PART |
|
|
|
Added by Inspector: 338 On 8/18/2000 approved resub for the masonry infill of the existing window to recive the new exaust ductand pending submittals and approval of damper information
|
Case Summary (BLD) | | | 8/3/2000 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 7/7/2000 | | 7/7/2000 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/7/2000 | | PASS |
Ron Hill
|
|
|
|
Case Summary (BLD) | | | 7/7/2000 | | DONE |
|
|
|
|
Print Occupancy Form | | | 7/7/2000 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 7/7/2000 | | DONE |
|
|
|
|
Telephone call | | | 7/7/2000 | | DONE |
|
|
|
called left message
|
Issue PAID IN FULL permit | | | 7/7/2000 | | DONE |
|
|
|
|
Plan assigned to (R_H) | 6/22/2000 | | 7/7/2000 | | PASS |
|
|
|
7/7/2000 10:20:02 RMH - activity updated through activity BLDA022 from case BLD00-01722.
|
Plan Review Completed(1st rev) | | | 7/6/2000 | | PASS |
|
|
|
|
Routing - FIRE | 7/5/2000 | | 7/6/2000 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 6/23/2000 | | 7/5/2000 | | PEND |
Ron Hill
|
|
|
Route to fire department for approvals.
|
Plan Reviewer's activity | | | 7/5/2000 | | PEND |
Ron Hill
|
|
|
Called Pete Rockwell, told him that I needed the engineering signed and stamped by the engineer that did the design calculations (Stapley Engineering)
|
Routing - PUBLIC WORKS | 6/22/2000 | | 6/23/2000 | | PASS |
|
|
|
|
Pending Assignment by MYS | 6/15/2000 | | 6/22/2000 | | DONE |
Marlene Southard
|
|
|
|
Routing - PLUMBING | 6/15/2000 | | 6/20/2000 | | PASS |
|
|
|
Routed to plumbing then route to Marlene for assignment
|
Application received | | | 6/15/2000 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | | | |
|
|
|
|
Routing - PLAN CHECK | 10/11/2000 | | | | |
|
|
|
FORWARDED RESUBMITTALS FROM DAVID LIGHTFOOT TO RON HILL. 10/11/00 DAR
|