Case Summary (BLD) | | | 3/19/2004 | | |
|
|
|
|
BLD-Final | 1/8/2001 | 1/8/2001 | 1/8/2001 | P | PASS |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 01/08/2001 at 08:17:37. Contact: ###-####.
|
FIRE-Final Inspection | 1/8/2001 | 1/8/2001 | 1/8/2001 | P | PASS |
Rick Jackson
|
|
|
Scheduled by Inspector: 409 On 1/8/2001 2:03:02 PM
|
BLD-Final | 1/4/2001 | 1/5/2001 | 1/5/2001 | P | FAIL |
Tony Young
|
|
|
FN OCC-- ROD- ###-#### OR ###-####
trades not signed off,, conference on hand rail, guard rail, landings, landscape etc. 1/5/2001 3:27:08 PM
|
FIRE-Sprinkler Rough-in | 11/28/2000 | 11/28/2000 | 11/28/2000 | P | PASS |
Rick Jackson
|
|
|
fire r/i--greg ###-#### //// okay to cover 11/28/2000 2:27:38 PM
|
BLD-Framing/Rough-in | 11/22/2000 | 11/24/2000 | 11/24/2000 | A | PART |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 11/22/2000 at 12:21:21. Contact: ###-####.
need sprinklers signed off, then ok to cover 11/24/2000 10:40:52 AM
|
BLD-Framing/Rough-in | 11/16/2000 | 11/17/2000 | 11/17/2000 | P | PART |
Tony Young
|
|
|
Rodney ###-#### ###-####
trusses ok execpt girder in garage needs more nails,,need to finish c/n 11/17/2000 4:23:41 PM
|
BLD-Framing/Rough-in | 11/15/2000 | 11/16/2000 | 11/16/2000 | A | PART |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 11/15/2000 at 15:08:41. Contact: ###-####.
c/n posted, ok to insulate unaffected areas, need truss specs 11/16/2000 10:25:16 AM
|
BLD-Framing/Rough-in | 10/23/2000 | 10/23/2000 | 10/23/2000 | P | PART |
Tony Young
|
|
|
SHEAR PANEL JIM -###-####
exterior nailing only, verify hold downs later.
may have to retrofit, but nailing is ok 10/23/2000 2:39:05 PM
|
Override - Parcel Holds | | | 10/23/2000 | | |
|
|
|
|
BLD-Framing/Rough-in | 10/20/2000 | 10/20/2000 | 10/20/2000 | P | FAIL |
Tony Young
|
|
|
shear panel -jim ###-####
no plans, no one on site, do not side 10/20/2000 4:05:25 PM
|
Override - Parcel Holds | | | 10/20/2000 | | |
|
|
|
|
BLD-Foundation | 10/13/2000 | 10/16/2000 | 10/16/2000 | A | PART |
Tony Young
|
|
|
retaining wall Larry ###-####
ok ,wip 10/16/2000 10:26:34 AM
|
Override - Parcel Holds | | | 10/13/2000 | | |
|
|
|
|
BLD-Foundation | 10/3/2000 | 10/3/2000 | 10/3/2000 | P | PART |
Tom Arcoraci
|
|
|
brian ###-#### short wall west side of house 10/3/2000 2:55:10 PM
|
Override - Parcel Holds | | | 10/3/2000 | | |
|
|
|
|
BLD-Footing | 10/2/2000 | 10/2/2000 | 10/2/2000 | P | PART |
Tony Young
|
|
|
###-#### wanting to pour at 1
ok w/ verbal corrections,, retaining wall. 10/2/2000 2:46:30 PM
|
Override - Parcel Holds | | | 10/2/2000 | | |
|
|
|
|
BLD-Footing | 9/29/2000 | 9/29/2000 | 9/29/2000 | P | PART |
Tony Young
|
|
|
###-####
wip, ok 9/29/2000 4:45:08 PM
|
Override - Parcel Holds | | | 9/29/2000 | | |
|
|
|
|
BLD-Foundation | 8/18/2000 | 8/18/2000 | 8/18/2000 | P | PART |
Tony Young
|
|
|
Brent ###-####
ok to pour 8/18/2000 4:09:47 PM
|
BLD-Foundation | 8/17/2000 | 8/17/2000 | 8/17/2000 | P | PART |
Tom Arcoraci
|
|
|
Brent ###-#### done by 415 8/17/2000 4:55:37 PM Steel tied, part of forms in place, left notice to recall when forms are set for basement 8/18/00 9:13:13 AM
|
BLD-Footing | 8/15/2000 | 8/15/2000 | 8/15/2000 | P | PART |
Tony Young
|
|
|
###-#### wip looks good so far 8/15/2000 3:51:51 PM
|
Plan assigned to (DJO) | 8/1/2000 | 8/1/2000 | 8/9/2000 | | PASS |
Dan Overy
|
|
|
8/9/2000 09:08:04 DJO - activity updated through activity BLDA022 from case BLD00-01864.
|
Plan Review Report | | | 8/9/2000 | | DONE |
|
|
|
|
Plan Reviewer's activity | | | 8/9/2000 | | DONE |
|
|
|
log beam and column engineering received.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/9/2000 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 8/9/2000 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 8/9/2000 | | DONE |
|
|
|
|
Telephone call | | | 8/9/2000 | | DONE |
|
|
|
called Heartland at ###-#### permit ready for pickup
|
Override - Parcel Holds | | | 8/9/2000 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 8/9/2000 | | DONE |
|
|
|
|
Plan Reviewer's activity | | | 8/1/2000 | | DONE |
|
|
|
waiting for engineered calculations on log products before issuance of permit. load path from log column thru 4X6 post to be addressed. will red-line additional brg in basement.
|
Plans ACCEPTED BY PLAN CHECK | | | 8/1/2000 | | |
|
|
|
|
Routing - PUBLIC WORKS | 6/28/2000 | 6/28/2000 | 7/12/2000 | | PASS |
|
|
|
northwest sewer dist
|
Routing - PUBLIC WORKS GRADING | 6/28/2000 | 6/28/2000 | 7/12/2000 | | DONE |
Rita DeYoung
|
|
|
took to terry records 6/28/00. Approved as Category 1. Don't issue perit until Hillside Application appeal period has lapsed on Monday, July 24, 2000
|
Application received | | | 6/28/2000 | | |
|
|
|
|
Routing - PLAN CHECK | 7/14/2000 | 7/14/2000 | | | PEND |
|
|
|
|
Routing - PLANNING | 7/12/2000 | 7/12/2000 | | | PASS |
|
|
|
As per CFH00-00020.
|