Fee Review-notes | 8/8/2000 | 8/8/2000 | 5/16/2001 | | DONE |
|
|
|
additional value from subs
|
BLD-Final | 11/21/2000 | 11/22/2000 | 11/22/2000 | A | PASS |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 11/21/2000 at 15:51:50. Contact: ###-####.
|
Permanent Occupancy | | 11/22/2000 | 11/22/2000 | | DONE |
|
|
|
|
Permanent occupancy | | | 11/22/2000 | | DONE |
|
|
|
Perm. Occ. Cert. #8477 issued 11-22-00 to Regence Blue Shield offices on the 1st floor of the Pioneer Plaza II Bldg.
|
BLD-Final | 11/17/2000 | 11/20/2000 | 11/20/2000 | A | NR |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 11/17/2000 at 09:09:15. Contact: ###-####.
|
FIRE-Final Inspection | 10/26/2000 | 10/27/2000 | 10/27/2000 | A | PASS |
Rick Jackson
|
|
|
Scheduled by a contractor via Hello! on 10/26/2000 at 14:52:23. Contact: ###-####.
|
BLD-Final | 10/26/2000 | 10/27/2000 | 10/27/2000 | P | PART |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 10/26/2000 at 14:52:54. Contact: ###-####. 42 inch access to exit door/ 36 min ailes.10/27/2000 3:15:19 PM 10/27/2000 3:16:42 PM
|
FIRE-Final Inspection | 10/18/2000 | 10/19/2000 | 10/19/2000 | A | FAIL |
Rick Jackson
|
|
|
FOR 1ST FLOOR FIRE FN --ROD- ###-#### tested alarms - notification and detectors okay; need detector for NAC; replace batteries to 33 amp; exit signs; complete sprinklers; clear stair towers 10/19/2000 12:36:04 PM
|
BLD-Conference | 8/10/2000 | 8/10/2000 | 8/10/2000 | A | PART |
|
|
|
covered plmg w/o same insp came to confirm plmg insp was satisfied with method to reveal same 8/10/2000 9:59:09 AM
|
BLD-Framing/Rough-in | 8/1/2000 | 8/2/2000 | 8/2/2000 | A | PART |
|
|
|
herb--###-#### fr ok to cover with elec approvals 8/2/2000 10:42:15 AM
|
Issue PAID IN FULL permit | | | 8/1/2000 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 8/1/2000 | | DONE |
|
|
|
|
Print Occupancy Form | | | 8/1/2000 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 7/28/2000 | | 7/29/2000 | | PASS |
|
|
|
Plans approved and taken to front desk.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/29/2000 | | PASS |
|
|
|
|
Plan assigned to (JCB) | 7/3/2000 | | 7/29/2000 | | PASS |
Jason Blais
|
|
|
7/29/2000 11:36:15 JCB - activity updated through activity BLDA022 from case BLD00-01923.
|
Plan Review Completed(1st rev) | | | 7/27/2000 | | FAIL |
|
|
|
failed bldg review
|
Plan resubmittals received | | | 7/26/2000 | | DONE |
|
|
|
RECEIVED TWO COPIES OF REVISED SHEETS A0.0, A1.0, A1.1, A2.0, A2.1, A3.0, A3.1, TWO COPIES OF PLAN REVIEW RESPONSE. ROUTED TO JASON KMM
|
Routing - PLAN CHECK | 7/5/2000 | | 7/24/2000 | | FAIL |
|
|
|
Plan review report sent and faxed to architect. Written response required to a couple of items. Plans routed to fire dept.
|
Routing - FIRE | 7/24/2000 | | 7/24/2000 | | PASS |
|
|
|
|
Plan resubmittals requested | | | 7/24/2000 | | PEND |
|
|
|
Written response required for further review.
|
Routing - PUBLIC WORKS | 7/3/2000 | | 7/5/2000 | | PASS |
|
|
|
|
Plan routing begun/TENANTS | | | 7/3/2000 | | DONE |
|
|
|
Route to PUBLIC WORKS, PLAN CHECK and FIRE.
|
Application received | | | 7/3/2000 | | |
|
|
|
|
Pending Assignment by MYS | 7/3/2000 | | 7/3/2000 | | DONE |
Marlene Southard
|
|
|
|
Telephone Call | | | | | |
|
|
|
called permit ready
|