BLD-Final | 2/15/2001 | 2/15/2001 | 2/15/2001 | P | PASS |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 02/15/2001 at 08:09:19. Contact: ###-####. C/C issued 2/15/2001 12:18:16 PM
|
DOC - Permit Finaled | 2/15/2001 | 2/15/2001 | 2/15/2001 | P | PASS |
Jim Sly
|
|
|
Added by Inspector: 316 On 2/15/2001 12:17:58 PM
|
BLD-Final | 2/13/2001 | 2/14/2001 | 2/14/2001 | P | FAIL |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 02/13/2001 at 19:40:19. Contact: ###-####. C/N issued. 2/14/2001 1:40:26 PM
|
BLD-Energy code compliance | 12/11/2000 | 12/13/2000 | 12/13/2000 | A | PASS |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 12/11/2000 at 11:27:24. Contact: ###-####.
|
BLD-Framing/Rough-in | 12/11/2000 | 12/12/2000 | 12/12/2000 | A | PASS |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 12/11/2000 at 11:24:16. Contact: ###-####. Energy OK. 12/12/2000 10:09:07 AM
|
BLD-Framing/Rough-in | 12/6/2000 | 12/7/2000 | 12/7/2000 | P | NR |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 12/06/2000 at 09:15:33. Contact: ###-####. NR 12/7/2000 1:52:35 PM
|
BLD-Energy code compliance | 12/6/2000 | 12/7/2000 | 12/7/2000 | A | FAIL |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 12/06/2000 at 09:16:29. Contact: ###-####. C/N issued...Misc frame corr. and need trade R/Is. 12/7/2000 11:51:32 AM
|
BLD-Framing/Rough-in | 11/30/2000 | 12/1/2000 | 12/1/2000 | A | PART |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 11/30/2000 at 12:06:33. Contact: ###-####. Correction notice on site....Void..located strap Shear OK. 12/1/2000 2:19:57 PM 12/1/2000 2:20:21 PM
|
BLD-Footing | 10/24/2000 | 10/24/2000 | 10/24/2000 | P | PART |
Jim Sly
|
|
|
|
Issue PAID IN FULL permit | | | 10/17/2000 | | DONE |
|
|
|
|
Telephone call | | | 10/12/2000 | | DONE |
|
|
|
Called they are still going to build on this lot they just need to make sure that the people buying the home aren't going to make any structural changes. AJC
|
Telephone call | | | 10/5/2000 | | DONE |
|
|
|
CALLED LEFT MESSAGE
|
Routing - PLANNING | 9/8/2000 | 9/8/2000 | 9/8/2000 | | PASS |
|
|
|
changed lots
|
Inspection Record Card- Bld | | | 9/8/2000 | | DONE |
|
|
|
|
Plan assigned to (DJO) | 8/16/2000 | 8/16/2000 | 8/16/2000 | | PASS |
Dan Overy
|
|
|
8/16/2000 15:20:02 DJO - activity updated through activity BLDA022 from case BLD00-02183.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/16/2000 | | DONE |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 8/16/2000 | | DONE |
|
|
|
|
Telephone call | | | 8/16/2000 | | DONE |
|
|
|
called Scottsdale homes permit ready for pickup
|
Inspection Record Card- Bld | | | 8/16/2000 | | DONE |
|
|
|
|
Plan Review Report | | | 8/16/2000 | | DONE |
|
|
|
|
Plans ACCEPTED BY PLAN CHECK | | | 8/16/2000 | | |
|
|
|
|
Routing - PUBLIC WORKS | 7/27/2000 | 7/27/2000 | 7/31/2000 | | PASS |
|
|
|
|
Routing - PLANNING | 7/27/2000 | 7/27/2000 | 7/31/2000 | | PASS |
|
|
|
|
Application received | | | 7/27/2000 | | |
|
|
|
|
Routing - PUBLIC WORKS | 9/8/2000 | 9/8/2000 | | | PEND |
|
|
|
changed lots
|
Routing - PLAN CHECK | 7/31/2000 | 7/31/2000 | | | PEND |
|
|
|
|
Pending Assignment by DJO | 7/27/2000 | | | | PEND |
Dan Overy
|
|
|
|
Office Staff conference/action | | | | | PEND |
|
|
|
took plans from front desk as they changed lots
|
(F) Reprint permit | | | | | |
|
|
|
|