BLD-Final | 11/28/2000 | 11/29/2000 | 11/29/2000 | A | PASS |
Jim Sly
|
|
|
###-####
|
BLD-Final | 11/21/2000 | 11/22/2000 | 11/22/2000 | A | FAIL |
Dave Hannah
|
|
|
front of garage 8147 mike###-####
|
BLD-Energy code compliance | 10/31/2000 | 11/1/2000 | 11/1/2000 | P | PASS |
Jim Sly
|
|
|
Michael ###-####
|
BLD-Framing/Rough-in | 10/31/2000 | 10/31/2000 | 10/31/2000 | P | PASS |
Jim Sly
|
|
|
Mike ###-####
|
BLD-Foundation | 8/3/2000 | 8/4/2000 | 8/4/2000 | A | PART |
Tom Arcoraci
|
|
|
###-####
|
BLD-Footing | 8/3/2000 | 8/3/2000 | 8/3/2000 | P | PART |
Tom Arcoraci
|
|
|
###-#### pwi 8/4/2000 8:10:32 AM
|
Inspection Record Card- Bld | | | 8/3/2000 | | DONE |
|
|
|
|
Telephone call | | | 8/3/2000 | | DONE |
|
|
|
called permit ready
|
Issue PAID IN FULL permit | | | 8/3/2000 | | DONE |
|
|
|
|
Plan assigned to (DJO) | 8/2/2000 | 8/2/2000 | 8/2/2000 | | PASS |
Dan Overy
|
|
|
8/2/2000 16:13:05 DJO - activity updated through activity BLDA022 from case BLD00-02210.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/2/2000 | | DONE |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 8/2/2000 | | DONE |
|
|
|
|
Plans ACCEPTED BY PLAN CHECK | | | 8/2/2000 | | |
|
|
|
|
Routing - PUBLIC WORKS | 7/31/2000 | 7/31/2000 | 8/1/2000 | | PASS |
|
|
|
|
Routing - PLANNING | 7/31/2000 | 7/31/2000 | 8/1/2000 | | PASS |
|
|
|
|
Application received | | | 7/31/2000 | | |
|
|
|
|
Routing - PLAN CHECK | 8/1/2000 | 8/1/2000 | | | PEND |
|
|
|
|
Pending Assignment by DJO | 7/31/2000 | | | | PEND |
Dan Overy
|
|
|
|
(F) Reprint permit | | | | | |
|
|
|
|