BLD-Final | 3/28/2001 | 3/28/2001 | 3/28/2001 | P | PASS |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 03/28/2001 at 08:05:32. Contact: ###-####.
c of c# 20322 issued 3/28/2001 3:47:24 PM 3/28/2001 4:01:29 PM
|
DOC - Permit Finaled | 3/28/2001 | 3/28/2001 | 3/28/2001 | P | PASS |
Tony Young
|
|
|
Added by Inspector: 415 On 3/28/2001 3:48:26 PM
|
BLD-Energy code compliance | 1/9/2001 | 1/11/2001 | 1/11/2001 | A | NR |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 01/09/2001 at 20:14:57. Contact: ###-####.
will call back in 1/11/2001 10:43:05 AM
|
BLD-Energy code compliance | 1/11/2001 | 1/11/2001 | 1/11/2001 | P | PASS |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 01/11/2001 at 10:15:37. Contact: ###-####.
|
BLD-Framing/Rough-in | 1/9/2001 | 1/10/2001 | 1/10/2001 | A | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 01/09/2001 at 20:12:06. Contact: ###-####. recieved truss joist info and will put it in your box 415 joist and lvl meet engineering submited framing ok for insulation. 1/10/2001 3:05:20 PM
|
BLD-Framing/Rough-in | 1/3/2001 | 1/4/2001 | 1/4/2001 | A | FAIL |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 01/03/2001 at 17:45:07. Contact: ###-####.
wanted me to look at beam and joists cut out by plumbers, need to replace joists or get fix by tji,,, beam is ok per tji book 1/4/2001 10:09:00 AM
|
BLD-Framing/Rough-in | 1/2/2001 | 1/3/2001 | 1/3/2001 | A | PART |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 01/02/2001 at 17:17:41. Contact: ###-####.
garage shear ok 1/3/2001 10:15:34 AM
|
BLD-Framing/Rough-in | 12/27/2000 | 12/28/2000 | 12/28/2000 | P | PART |
Tony Young
|
|
|
Scheduled by Inspector: 415 On 12/27/2000 11:18:46 AM shear nail
ext. shear ok 12/28/2000 3:23:54 PM
|
BLD-Framing/Rough-in | 12/27/2000 | 12/27/2000 | 12/27/2000 | P | FAIL |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 12/27/2000 at 07:42:28. Contact: ###-####.
conference only, to many things on shear 12/27/2000 2:33:21 PM
|
BLD-Foundation | 11/15/2000 | 11/15/2000 | 11/15/2000 | P | PASS |
Dave Hannah
|
|
|
steve ###-#### found wall
|
BLD-Footing | 11/13/2000 | 11/14/2000 | 11/14/2000 | A | PART |
Dave Hannah
|
|
|
ft --dirk--###-####
|
Issue PAID IN FULL permit | | | 11/13/2000 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/13/2000 | | DONE |
|
|
|
|
Telephone call | | | 10/13/2000 | | DONE |
|
|
|
called ###-#### permits ready for pickup
|
Inspection Record Card- Bld | | | 10/13/2000 | | DONE |
|
|
|
|
Plan assigned to (SAM) | 10/9/2000 | | 10/13/2000 | | PASS |
Steve Munroe
|
|
|
10/13/2000 14:16:46 SAM - activity updated through activity BLDA022 from case BLD00-02411.
|
Pending Assignment by DJO | 8/14/2000 | | 10/9/2000 | | DONE |
Dan Overy
|
|
|
10/9/2000 11:13:44 SAM - activity updated through activity BLDA183 from case BLD00-02411.
|
Routing - PUBLIC WORKS | 8/14/2000 | 8/14/2000 | 9/25/2000 | | PASS |
|
|
|
fees paid to northwest sewer dist./lw
|
Routing - PLANNING | 8/14/2000 | 8/14/2000 | 9/22/2000 | | PASS |
|
|
|
roger put in rejection drawer, see him why, pe????????
|
Application received | | | 8/14/2000 | | |
|
|
|
|
Routing - PLAN CHECK | 9/25/2000 | 9/25/2000 | | | PEND |
|
|
|
|
Plan Reviewer's activity | | | | | PEND |
|
|
|
10/9/00 13:20 I talked with Tim with Media One about the brace panels being shown. He said he will get me new sheets (floor plans) for each of the five houses.
|
Print Pending Permit.LaserJet4 | | | | | |
|
|
|
|
Plan Review Report | | | | | |
|
|
|
|
Print Pending Permit.LaserJet4 | | | | | |
|
|
|
|