BLD-Final | 3/14/2001 | 3/14/2001 | 3/14/2001 | A | PASS |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 03/14/2001 at 07:05:06. Contact: ###-####. C. of C. #20227 issued. 3/14/2001 11:37:44 AM
|
BLD-Energy code compliance | 1/26/2001 | 1/26/2001 | 1/26/2001 | P | PASS |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 01/26/2001 at 11:05:11. Contact: ###-####. ok to cover 1/26/2001 1:05:20 PM
|
BLD-Conference | 1/26/2001 | 1/26/2001 | 1/26/2001 | P | PASS |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 01/26/2001 at 11:05:51. Contact: ###-####.
|
BLD-Concrete | 1/24/2001 | 1/25/2001 | 1/25/2001 | P | CANC |
Tom Arcoraci
|
|
|
Added by Inspector: 408 On 1/24/2001 3:38:41 PM
|
BLD-Framing/Rough-in | 1/24/2001 | 1/24/2001 | 1/24/2001 | P | PART |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 01/24/2001 at 10:34:25. Contact: ###-####. needs new truss 1/24/2001 3:34:30 PM
|
BLD-Framing/Rough-in | 1/23/2001 | 1/23/2001 | 1/23/2001 | P | FAIL |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 01/23/2001 at 10:48:48. Contact: ###-####.c/n issued--1) Need mechanical, 2) Air seal package needed, 3) Mistake between trusses and truss package, i. e. T14, 15 (missing web and T7 in garage not like the diagram in package, 4) Tempered glass need to left of patio double door, and 5) Solid bearing needed in header at window in study, marked with black x on floor. 1/23/2001 2:17:52 PM
|
BLD-Wall cover | 1/3/2001 | 1/3/2001 | 1/3/2001 | A | PART |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 01/03/2001 at 07:23:46. Contact: ###-####.c/n issued. exterior shear ok. 1/3/2001 10:48:39 AM
|
BLD-Foundation | 10/26/2000 | 10/27/2000 | 10/27/2000 | A | PART |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 10/26/2000 at 14:14:14. Contact: ###-####. still no string lines at property lines walls ok.
10/27/2000 1:10:27 PM
|
BLD-Footing | 10/25/2000 | 10/26/2000 | 10/26/2000 | A | PART |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 10/25/2000 at 16:57:32. Contact: ###-####.appears ok no string lines for inspection of left and right side p/l. 10/26/2000 10:21:29 AM
|
BLD-Footing | 10/25/2000 | 10/25/2000 | 10/25/2000 | P | NR |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 10/25/2000 at 07:11:54. Contact: ###-####.nothing here. 10/26/2000 9:02:56 AM
|
Issue PAID IN FULL permit | | | 9/18/2000 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/15/2000 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 9/15/2000 | | DONE |
|
|
|
|
Plan assigned to (SAM) | 9/14/2000 | | 9/15/2000 | | PASS |
Steve Munroe
|
|
|
9/15/2000 12:38:07 SAM - activity updated through activity BLDA022 from case BLD00-02436.
|
Pending Assignment by DJO | 8/15/2000 | | 9/14/2000 | | DONE |
Dan Overy
|
|
|
9/14/2000 10:32:00 SAM - activity updated through activity BLDA183 from case BLD00-02436.
|
Routing - PLANNING | 8/30/2000 | 8/30/2000 | 8/31/2000 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 8/16/2000 | 8/16/2000 | 8/17/2000 | | PASS |
|
|
|
|
Routing - PLANNING | 8/16/2000 | 8/16/2000 | 8/16/2000 | | PASS |
|
|
|
|
Application received | | | 8/15/2000 | | |
|
|
|
|
Routing - PLAN CHECK | 8/17/2000 | 8/17/2000 | | | PEND |
|
|
|
|
Print Pending Permit.LaserJet4 | | | | | |
|
|
|
|
Plan Review Report | | | | | |
|
|
|
|