Permit NumberBLD00-02766
StatusFinaled
Name US WEST
Site Address 619 W BANNOCK ST
Project NameAT & T BUILDING-1ST FLR
Customer Number 
ePlanReviewNo
Description
**DEMOLITION PERMIT ONLY AS DESCRIBED BELOW - 619 W. BANNOCK, US WEST / AT&T BUILDING, 1ST FLOOR ** To prepare a 1,400 sq. ft. area located in the northeast corner of the 1st floor of the AT&T / US WEST, building for remodel by demolition of interior nonbearing walls & ceilings; mechanical demolition; removal of 2 pumps & piping. The Fire Sprinkler System layout, Vesda Smoke Detection System, and Pre-Action System SHALL not be removed or altered under this demolition permit. The scope of demo work SHALL not affect the proper functioning of these systems. Plans for proposed remodel have been submitted for review under BLD00-02827. This demolition and future remodel will require modification of the above noted systems and relocation / construction of 1-hour occupancy separations & protection of penetrations / openings at new fire wall locations. NO NEW CONSTRUCTION IS ALLOWED WITHIN THE SCOPE OF THIS DEMOLITION PERMIT. ALL EXISTING SPRINKLER, SMOKE, PRE-ACTION SYSTEMS SHALL REMAIN IN PLACE & OPERATIONAL WITH NO OCCUPANCY OR USE ALLOWED WITHIN THE AREA OF THE DEMOLITION PERMIT SCOPE. All per approved demo plans and notes on file. ALL WORK WITHIN THIS BUILDING IS SUBJECT TO THE AUGUST 1992 LETTER OF AGREEMENT ON FILE. NOTE: This building is partially fire sprinklered and partially equiped with smoke detection / pre-action system based on 1992 Letter of Agreement on file. (P.C.#748-00)/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/8/20018/8/20018/8/2001PPASS
DetailsCarl Dependahl
Added by Inspector: 340 On 8/8/2001 2:38:39 PM demo ok
DOC - Permit Finaled8/8/20018/8/20018/8/2001PPASS
DetailsCarl Dependahl
Finaled by inspector at 8/8/2001 2:38:54 PM
Issue PAID IN FULL permit  10/2/2000 DONE
Plan assigned to (DRS)9/21/2000 9/29/2000 PASS
DetailsDan Stuart
9/29/2000 13:02:59 DRS - activity updated through activity BLDA022 from case BLD00-02766.
Routing - PLAN CHECK9/22/2000 9/29/2000 PASS
Approved for demolition work only as described within body of permit.
Telephone call  9/29/2000 DONE
DetailsDan Stuart
Called Bob Smith, architect, to review the existing building and the 1992 letter of agreement and if was aware of the requirements for the sprinkler system, smoke detection, pre-action and occupancy separation wall requirements and review with him that this demolition and proposed remodel will require relocation of each of these items based on the new area uses. Stated to him that the sprinkler, smoke, & preaction systems could not be modified in the least under this demo permit and that I would specifically not this fact in the permit. He understood the situation. I told him I would call the contractor and review with him the specific limits of the permit.
Meeting  9/29/2000  
Had Bill Alexander come to my desk to review with him the intended demolition and future proposed remodel. Discussed the sprinkler system & smoke detection / pre-action system and the different areas covered by one or the other and that the demo permit would be issued with specific limits. I let Bill read the permit and modified per his suggestions. Preparing to rout for issuance of demo permit only aslisted in permit.
PLANS/APPL TAKEN TO FRONT DESK  9/29/2000 PASS
Routed to permit desk for issuance per specific notes in body of permit.
Inspection Record Card- Bld  9/29/2000 DONE
Application received  9/18/2000  
Plans ACCEPTED BY PLAN TECH  9/18/2000 DONE
Received Certificate of Value  9/18/2000 DONE
Routing - FIRE6/29/2000 6/29/2000 PASS
Reviewed plans with Bill Alexander, ire code analyst for sprinkler system plans and had him review my demolition permit for thought or comments he wanted included. Made modifications to permit body. Bill stated he would cover requirements for system modifications in his review of the plans routing for the proposed remodel/use changes in the area.