BLD-Final | 7/15/2014 | 7/16/2014 | 7/16/2014 | A | PASS |
Mike Jordan
|
|
|
vince Phone #: ###-####
|
DOC - Permit Finaled | 7/16/2014 | 7/16/2014 | 7/16/2014 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 7/11/2014 | 7/14/2014 | 7/14/2014 | A | CANC |
Mike Jordan
|
|
|
Vince-please call for access, if no anser please call Denise ###-#### or ###-#### Phone #: ###-####.
|
BLD-Final | 7/14/2014 | 7/14/2014 | 7/14/2014 | P | FAIL |
Mike Jordan
|
|
|
Provide smoke detectors in bedrooms.
|
BLD-Other | 7/11/2014 | 7/11/2014 | 7/11/2014 | A | DONE |
Mike Jordan
|
|
|
Ok to schedule final inspection with $46.31 admin fee.
|
CHANGE STATUS TO (ISS) | | | 7/11/2014 | | DONE |
Candy A. Nichols
|
|
|
as per Bob Archibald, ok to change status from expired to issued once admin fee has been paid
|
PostCard Mailed | | | 5/10/2003 | | SENT |
|
|
|
PostCard has been mailed requesting inspection.
|
Extend Permit 180 days | | 10/4/2002 | 10/4/2002 | | DONE |
|
|
|
still working
|
PostCard Mailed | | | 9/29/2002 | | SENT |
|
|
|
PostCard has been mailed requesting inspection.
|
BLD-Final | 3/20/2002 | 3/21/2002 | 3/21/2002 | P | FAIL |
Russ Owen
|
|
|
dan ###-#### fn c/n. 3/21/2002 4:34:51 PM
|
BLD-Final | 1/25/2002 | 1/31/2002 | 1/31/2002 | P | CANC |
Russ Owen
|
|
|
###-####--fn-- dan Called owner explained about the need for other trades to sign off prior to bld final. 1/31/2002 2:36:46 PM
|
BLD-Framing/Rough-in | 9/28/2001 | 10/1/2001 | 10/1/2001 | P | PART |
Russ Owen
|
|
|
984 BEN. work in progress, owner had en questions. 10/1/2001 5:00:29 PM
|
BLD-Energy code compliance | 7/24/2001 | 7/25/2001 | 7/25/2001 | A | PASS |
Russ Owen
|
|
|
###-####
|
BLD-Energy code compliance | 7/16/2001 | 7/16/2001 | 7/16/2001 | P | PART |
Russ Owen
|
|
|
Dan Short ###-####. need to have beam upper floor over window sized as per c/n also still need to work on wall at house side in basement for fire blocking. 7/16/2001 3:24:12 PM
|
BLD-Energy code compliance | 7/6/2001 | 7/9/2001 | 7/9/2001 | P | FAIL |
Russ Owen
|
|
|
energy code-- ###-#### cell danial.posted c/n NOTE:cotractor and owner doing most all work here,and are not familiar with all related codes and trades. 7/10/2001 10:52:55 AM
|
BLD-Framing/Rough-in | 6/28/2001 | 6/29/2001 | 6/29/2001 | P | PART |
Russ Owen
|
|
|
###-#### c/n posted ok insulate. 6/29/2001 1:57:40 PM
|
BLD-Framing/Rough-in | 6/18/2001 | 6/19/2001 | 6/19/2001 | P | NR |
Russ Owen
|
|
|
drywall needs mec/ele/plm. 1/19/2002 4:35:04 PM
|
Extend Permit 180 days | | 5/21/2001 | 5/21/2001 | | DONE |
|
|
|
homeowner
|
BLD-Framing/Rough-in | 3/16/2001 | 3/19/2001 | 3/19/2001 | A | PART |
Russ Owen
|
|
|
CALL ###-#### COLEEN AFTER 11:00 CALL ###-#### . wanted to Know about beam in living room ,has girder that appears to be designed to cary ext roof, told them to verify with truss company,also told them to maintain slope of of ext deck over basement area, need pt for plates in basement, no other frame ispection done. not ready conference only. 3/19/2001 12:41:46 PM
|
BLD-Conference | 3/15/2001 | 3/16/2001 | 3/16/2001 | A | NH |
Tom Arcoraci
|
|
|
rick ###-#### for conf
|
BLD-Framing/Rough-in | 3/15/2001 | 3/16/2001 | 3/15/2001 | A | CANC |
Russ Owen
|
|
|
###-#### Rick cancelled by Colleen
|
BLD-Footing | 1/10/2001 | 1/10/2001 | 1/10/2001 | P | CANC |
Jim Storey
|
|
|
Eric ###-#### Eric ###-#### 425 called and is on site will add insp. 1/10/2001 3:13:22 PM
|
BLD-Footing | 1/10/2001 | 1/10/2001 | 1/10/2001 | P | PART |
Dave Hannah
|
|
|
Added by Inspector: 425 On 1/10/2001 3:31:02 PM crew used #4 bar plans call for 5 engineer ok to double 4bar
|
BLD-Foundation | 1/10/2001 | 1/10/2001 | 1/10/2001 | P | PART |
Dave Hannah
|
|
|
Added by Inspector: 425 On 1/10/2001 3:34:59 PM crew is working on wall what they have in place is ok they are using #4 at 6inchs on center as per engin ok
|
BLD-Foundation | 1/10/2001 | 1/10/2001 | 1/10/2001 | P | PART |
Dave Hannah
|
|
|
Added by Inspector: 425 On 1/10/2001 3:34:59 PM crew is working on wall what they have in place is ok they are using #4 at 6inchs on center as per engin ok
|
BLD-Footing | 1/10/2001 | 1/10/2001 | 1/10/2001 | P | PART |
Dave Hannah
|
|
|
Added by Inspector: 425 On 1/10/2001 3:31:02 PM crew used #4 bar plans call for 5 engineer ok to double 4bar
|
BLD-Footing | 1/2/2001 | 1/3/2001 | 1/3/2001 | A | CANC |
Alan Hauser
|
|
|
#425 1/3/2001 12:06:03 PM
|
Plan resubmittals received | | | 12/15/2000 | | DONE |
|
|
|
Received plan resubmittals from Patrick McKeegan, forwarded them to Dave Hannah. 12/15/00
|
BLD-Conference | 12/11/2000 | 12/11/2000 | 12/11/2000 | P | FAIL |
Dave Hannah
|
|
|
###-#### 12/11/2000 3:32:56 PMwrote c/n contractor is to stop work resubmit plans 12/11/2000 3:39:47 PM
|
BLD-Conference | 10/31/2000 | 10/31/2000 | 10/31/2000 | P | PASS |
Carl Dependahl
|
|
|
###-####
|
Issue PAID IN FULL permit | | | 10/16/2000 | | DONE |
|
|
|
|
Plan assigned to (SAM) | 9/29/2000 | | 10/13/2000 | | PASS |
Steve Munroe
|
|
|
10/13/2000 16:12:36 SAM - activity updated through activity BLDA022 from case BLD00-02949.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/13/2000 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 10/13/2000 | | DONE |
|
|
|
|
Telephone call | | | 10/13/2000 | | DONE |
|
|
|
called Daniel Short permit ready for pickup
|
Application received | | | 9/29/2000 | | |
|
|
|
|
Plans ACCEPTED BY PLAN CHECK | | | 9/29/2000 | | |
|
|
|
|
Plan Reviewer's activity | | | | | FAIL |
|
|
|
9/29/00 Called the owner/builder and the architect and informed them that the plans need to be re-drawn with corrections incorporated. I am giving the architect one set back with red-lining.
|
Print Pending Permit.LaserJet4 | | | | | |
|
|
|
|
Plan Review Report | | | | | |
|
|
|
|