BLD-Aging Inspection | 5/28/2003 | 5/28/2003 | 5/28/2003 | | CANC |
Tom Arcoraci
|
|
|
other permits issued 5/28/2003 8:50:04 AM
|
DOC - Permit Expired | 5/28/2003 | 5/28/2003 | 5/28/2003 | A | PASS |
Tom Arcoraci
|
|
|
Expired by inspector at 5/28/2003 8:50:14 AM
|
BLD-Aging Inspection | 3/25/2003 | 3/25/2003 | 3/25/2003 | | PASS |
Tom Arcoraci
|
|
|
ec ok 3/26/2003 2:57:01 PM energ/code ok 3/26/2003 2:57:01 3/26/2003 2:57:59 PM
|
BLD-Conference | 1/7/2003 | 1/7/2003 | 1/7/2003 | A | DONE |
Tom Arcoraci
|
|
|
|
BLD-Framing/Rough-in | 1/11/2001 | 1/12/2001 | 1/12/2001 | A | PART |
Tom Arcoraci
|
|
|
###-#### please call before you go out so that he can be there wip ok to cover tennant demise wall 1/12/2001 11:25:15 AM
|
BLD-Conference | 12/15/2000 | 12/15/2000 | 12/15/2000 | A | PASS |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 12/15/2000 10:36:16 AM w/ Randy
|
BLD-Framing/Rough-in | 12/13/2000 | 12/13/2000 | 12/13/2000 | P | PART |
Tom Arcoraci
|
|
|
FR INSP RANDY-- ###-####--CALL 1ST BEFORE INSP wip ok to cover half of int walls and part of occ wall 12/13/2000 4:48:13 PM
|
Inspection Record Card- Bld | | | 11/30/2000 | | DONE |
|
|
|
|
Print Occupancy Form | | | 11/30/2000 | | DONE |
|
|
|
|
Telephone call | | | 11/30/2000 | | DONE |
|
|
|
randy called gave dollar amount
|
Issue PAID IN FULL permit | | | 11/30/2000 | | DONE |
|
|
|
|
Routing - PUBLIC WORKS | 11/29/2000 | 11/29/2000 | 11/29/2000 | | PASS |
|
|
|
Located in Bench Sewer District.
|
Routing - PLAN CHECK | 11/29/2000 | 11/29/2000 | 11/29/2000 | | PASS |
|
|
|
Received plans back from PW. BAD signed off, in Bench Sewer District. COPY OF PLAN REVIEW COMMENTS CONCERNING REQUIREMENTS FOR CODE UPGRADE FOR ALL SPACES TO OBTAIN A C.O. FOR EACH TENANT FAXED TO CORNELL LARSON & RANDY HEMMER. COPY MAILED TO CORNELL.
|
Plan assigned to (DRS) | 10/23/2000 | 10/23/2000 | 11/29/2000 | | PASS |
Dan Stuart
|
|
|
11/29/2000 15:49:04 DRS - activity updated through activity BLDA022 from case BLD00-03152.
|
Telephone call | | | 11/29/2000 | | DONE |
|
|
|
Phone call from Cornell larson, Larson Architects. He has received and reviewed the plans check comments & has revisited the site and individual tenant spaces. Randy has told him to proceed to make the situation right for each tenant and it appears that the 1-hour occupancy separation walls at the "S-3" Occupancy, Extreme Motosports (5662 Franklin) and a Area Separation Wall of 4-hours Construction between the Brico space at 5858 Franklin, to be III-N and the other four spaces, 5862, 5866, 5878, 5880 Franklin to be II-FR. The 1,440 sq.ft. wood storage against the exterior North wall will need to be reviewed to see if it needs to be demoed or a four hour wall can be created between the two types of construction. Cornell will try and send a summary letter by the end of the week stating what he has found, what appears to be needed and what the rate of progress Randy Hemmer wants to follow. BRICO seams to be the problem occupancy based on quantities of possible hazaedous materials exceeding the allowable and requiring classification as a "H" occupancy and possible srinkler system requirements.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/29/2000 | | PASS |
|
|
|
Routing to permit desk for issuance.
|
Routing - PLAN CHECK | 10/25/2000 | 10/25/2000 | 11/27/2000 | | PEND |
|
|
|
PLANS SUBMITTED FOR INTERIOR VANILLA FINISH FOR TWO FUTURE TENANT SPACES, 5880 & 5878 Franklin, REVEALED THAT THERE ARE THREE ILLEGAL TENANTS, 5866 (Action Paintball), 5862 (Power Extreme Motosports), and 5858 (BRICO), Franklin Road, OCCUPYING THE OTHER PARTS OF THE BUILDING THAT HAVE NOT FOLLOWED BOISE CITY REQUIREMENTS FOR OCCUPANCY & USE. I HAVE REVIEWED THE CONDITIONS IN QUESTION WITH THE ARCHITECT, CORNELL LARSON AND BILL ALEXANDER OF THE FIRE DEPARTMENT PLAN REVIEW DIV. THE PERMIT IS ISSUED WITH CONDITIONS OF APPROPRIATE SUBMITTALS OF APPLICATIONS AND PLANS FOR EACH EXISTING OCCUPIED TENANT SPACE WITH THE ULTIMATE OBJECTIVE BEING THE GIVING OF A CERTIFICATE OF OCCUPANCY FOR EACH EXISTING TENANT AND THE PROPOSED FUTURE TENANTS. THE TYPE OF CONSTRUCTION IS OF CONCERN AND IS TO BE VERIFIED AND ANY REMOVAL OF NON-COMLPYING CONSTRUCTION TO BE A PART OF THE SUBMITTAL PROCESS. TYPE OF CONSTRUCTION IS A CONCERN THAT MAY REQUIRE THE INSTALLATION OF A SPRINKLER SYSTEM TO MEET CODE IF THE TYPE II-FR HAS NOT BEEN MAINTAINED.
|
Meeting | | | 11/27/2000 | | |
|
|
|
MET WITH BILL ALEXANDER TO EXPLAIN WHAT I WAS TRYING TO ACCOMPLISH BY ISSUING PERMIT FOR 'NEW TENANT 1 & 2' SPACES FOR VANILLA FINISH, NO OCCUPANCYU OR USE ALLOWED WHILE GIVING THEM A LIST OF ITEMS THAT WOULD NEED TO BE ANSWERED FOR THE ENTIRE BUILDING, WHICH HAS THREE EXISTING TENANTS WHICH DO NOT HAVE CERTIFICATES OF OCCUPANCY AND WILL NEED TO BECOME PART OF THE SUBMITTAL REVIEW PROCESS WITH THE OWNER / TENANT & ARCHITECT TO MOVE FORWARD WITH PERMITS FOR THE NEW TENANT SPACES. BILL FELT THAT AS LONG AS I SPELLED OUT THAT THERE ARE CONCERNS ON TYPE OF CONSTRUCTION, FIRE FLOW (GPM WATER AVAILABILITY AT SITE), LOCATION OF FIRE HYDRANTS, OCCUPANCY USE GROUPS AND CODE UPGRADES AS APPLICABLE FOR ISSUANCE OF C.O.'S, THIS BEING THE OBJECTIVE FOR ALL TENANT SPACES.
|
Application received | | | 10/20/2000 | | |
|
|
|
|
Fee Review-notes | 10/20/2000 | 10/20/2000 | | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | | | |
|
|
|
|