Permit Information
Permit NumberBLD00-03152
StatusExpired
Name "VANILLA FINISH'S" / RANDY HEMMER
Site Address 5880 W FRANKLIN RD
Project Name 
Customer Number 
ePlanReviewNo
Description
*2-NEW VANILLA SPACES / 3-TENANTS W/O C.O.'S* TO CONSTRUCT TENANT & OCCUPANCY SEPARATION WALLS / ACCESSIBILITY RESTROOM UPGRADE'S / MODIFY & ADD EXTERIOR STOREFRONT ENTRANCES & MAKE STRUCTURAL MODIFICATIONS TO ADD OPENING FOR OVERHEAD DOOR AT NW CORNER OF FUTURE 'NEW TENANT#2' SPACE.* To construct a new 1-hour tenant separation wall between FUTURE 'New Tenant' Spaces '#1 & #2'; to finish or bring into compliance the 1-hour Occupancy Separation Wall between the 'Existing Tenant #2' & 'New Tenant #2' spaces. This is an existing TYPE II-FR building, per architects report, total area of 29,400 sq. ft., being divided into five tenant spaces. NOTE: There are no Certificates of occupancy for the existing tenants showing legal occupancy. Permits for the two "FUTURE TENANTS" within 'New Tenant #1 & #2' spaces, will not be issued until architectural code analysis is performed for each tenant space and two copies of plans and application for each tenant space (existing & future) are provided for review, approval by City and permits issued for upgrades or occupancy approval inspections as applicable. Final objective to have each tenant legally occupying, with a certificate of occupancy for each tenant based on declared occupancy use(s). Analysis SHALL include verification of/for: 1) Compliance with construction type throughout; 2) Designate Occupancy Use Group Classification(s) for each area W/I tenant space; 3) Indicate location & construction for for Occupancy Separations, as applicable, based on use; 4) Evaluation of existing available fire flow (obtain & provide copy of GPM of water from water company available at site) to determine applicable sprinkler system requirements per 1997 UFC, Appendix III-A, based on Const. Type & Occupancy Use; 5) Site plan with the location of fire hydrants, located per Boise Fire Dept, (contact Bill Alexander @ 395-7813 W/ Questions on fire flow or hydrant data required); 6) As Applicable, Floor Drains to Oil Separators or Traps for "S3" Occupancy; 7) and Show Compliance W/ Specific Occupancy Provisions per Current Adopted Codes For Each Occupancy Use. PC#00-944/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection5/28/20035/28/20035/28/2003 CANC
DetailsTom Arcoraci
other permits issued 5/28/2003 8:50:04 AM
DOC - Permit Expired5/28/20035/28/20035/28/2003APASS
DetailsTom Arcoraci
Expired by inspector at 5/28/2003 8:50:14 AM
BLD-Aging Inspection3/25/20033/25/20033/25/2003 PASS
DetailsTom Arcoraci
ec ok 3/26/2003 2:57:01 PM energ/code ok 3/26/2003 2:57:01 3/26/2003 2:57:59 PM
BLD-Conference1/7/20031/7/20031/7/2003ADONE
DetailsTom Arcoraci
BLD-Framing/Rough-in1/11/20011/12/20011/12/2001APART
DetailsTom Arcoraci
###-#### please call before you go out so that he can be there wip ok to cover tennant demise wall 1/12/2001 11:25:15 AM
BLD-Conference12/15/200012/15/200012/15/2000APASS
DetailsCarl Dependahl
Added by Inspector: 340 On 12/15/2000 10:36:16 AM w/ Randy
BLD-Framing/Rough-in12/13/200012/13/200012/13/2000PPART
DetailsTom Arcoraci
FR INSP RANDY-- ###-####--CALL 1ST BEFORE INSP wip ok to cover half of int walls and part of occ wall 12/13/2000 4:48:13 PM
Inspection Record Card- Bld  11/30/2000 DONE
Print Occupancy Form  11/30/2000 DONE
Telephone call  11/30/2000 DONE
randy called gave dollar amount
Issue PAID IN FULL permit  11/30/2000 DONE
Routing - PUBLIC WORKS11/29/200011/29/200011/29/2000 PASS
Located in Bench Sewer District.
Routing - PLAN CHECK11/29/200011/29/200011/29/2000 PASS
Received plans back from PW. BAD signed off, in Bench Sewer District. COPY OF PLAN REVIEW COMMENTS CONCERNING REQUIREMENTS FOR CODE UPGRADE FOR ALL SPACES TO OBTAIN A C.O. FOR EACH TENANT FAXED TO CORNELL LARSON & RANDY HEMMER. COPY MAILED TO CORNELL.
Plan assigned to (DRS)10/23/200010/23/200011/29/2000 PASS
DetailsDan Stuart
11/29/2000 15:49:04 DRS - activity updated through activity BLDA022 from case BLD00-03152.
Telephone call  11/29/2000 DONE
Phone call from Cornell larson, Larson Architects. He has received and reviewed the plans check comments & has revisited the site and individual tenant spaces. Randy has told him to proceed to make the situation right for each tenant and it appears that the 1-hour occupancy separation walls at the "S-3" Occupancy, Extreme Motosports (5662 Franklin) and a Area Separation Wall of 4-hours Construction between the Brico space at 5858 Franklin, to be III-N and the other four spaces, 5862, 5866, 5878, 5880 Franklin to be II-FR. The 1,440 sq.ft. wood storage against the exterior North wall will need to be reviewed to see if it needs to be demoed or a four hour wall can be created between the two types of construction. Cornell will try and send a summary letter by the end of the week stating what he has found, what appears to be needed and what the rate of progress Randy Hemmer wants to follow. BRICO seams to be the problem occupancy based on quantities of possible hazaedous materials exceeding the allowable and requiring classification as a "H" occupancy and possible srinkler system requirements.
PLANS/APPL TAKEN TO FRONT DESK  11/29/2000 PASS
Routing to permit desk for issuance.
Routing - PLAN CHECK10/25/200010/25/200011/27/2000 PEND
PLANS SUBMITTED FOR INTERIOR VANILLA FINISH FOR TWO FUTURE TENANT SPACES, 5880 & 5878 Franklin, REVEALED THAT THERE ARE THREE ILLEGAL TENANTS, 5866 (Action Paintball), 5862 (Power Extreme Motosports), and 5858 (BRICO), Franklin Road, OCCUPYING THE OTHER PARTS OF THE BUILDING THAT HAVE NOT FOLLOWED BOISE CITY REQUIREMENTS FOR OCCUPANCY & USE. I HAVE REVIEWED THE CONDITIONS IN QUESTION WITH THE ARCHITECT, CORNELL LARSON AND BILL ALEXANDER OF THE FIRE DEPARTMENT PLAN REVIEW DIV. THE PERMIT IS ISSUED WITH CONDITIONS OF APPROPRIATE SUBMITTALS OF APPLICATIONS AND PLANS FOR EACH EXISTING OCCUPIED TENANT SPACE WITH THE ULTIMATE OBJECTIVE BEING THE GIVING OF A CERTIFICATE OF OCCUPANCY FOR EACH EXISTING TENANT AND THE PROPOSED FUTURE TENANTS. THE TYPE OF CONSTRUCTION IS OF CONCERN AND IS TO BE VERIFIED AND ANY REMOVAL OF NON-COMLPYING CONSTRUCTION TO BE A PART OF THE SUBMITTAL PROCESS. TYPE OF CONSTRUCTION IS A CONCERN THAT MAY REQUIRE THE INSTALLATION OF A SPRINKLER SYSTEM TO MEET CODE IF THE TYPE II-FR HAS NOT BEEN MAINTAINED.
Meeting  11/27/2000  
MET WITH BILL ALEXANDER TO EXPLAIN WHAT I WAS TRYING TO ACCOMPLISH BY ISSUING PERMIT FOR 'NEW TENANT 1 & 2' SPACES FOR VANILLA FINISH, NO OCCUPANCYU OR USE ALLOWED WHILE GIVING THEM A LIST OF ITEMS THAT WOULD NEED TO BE ANSWERED FOR THE ENTIRE BUILDING, WHICH HAS THREE EXISTING TENANTS WHICH DO NOT HAVE CERTIFICATES OF OCCUPANCY AND WILL NEED TO BECOME PART OF THE SUBMITTAL REVIEW PROCESS WITH THE OWNER / TENANT & ARCHITECT TO MOVE FORWARD WITH PERMITS FOR THE NEW TENANT SPACES. BILL FELT THAT AS LONG AS I SPELLED OUT THAT THERE ARE CONCERNS ON TYPE OF CONSTRUCTION, FIRE FLOW (GPM WATER AVAILABILITY AT SITE), LOCATION OF FIRE HYDRANTS, OCCUPANCY USE GROUPS AND CODE UPGRADES AS APPLICABLE FOR ISSUANCE OF C.O.'S, THIS BEING THE OBJECTIVE FOR ALL TENANT SPACES.
Application received  10/20/2000  
Fee Review-notes10/20/200010/20/2000   
Recd Pcfee & Taken To Pln CK