Permit Information
Permit NumberBLD00-03478
StatusFinaled
Name PRONTO - PUPS / PETER PETERSON
Site Address 245 S CAPITOL BLVD
Project NameGROVE HOTEL
Customer Number 
ePlanReviewNo
Description
*PRONTO PUPS KIOSK & GILES FSH-5 RECIRCULATING GREASE HOOD* To install a Giles FSH-5 Recirculating Type I Grease Hood per ICBO EVALUATION SERVICES REPORT, ER-5148, copy attached. Approved for a maximum of two fryer vats in compliance with listing. Verification of installation and functioning of required safety features per manufacture's listing, copy included, and all interconnected fire / life safety features from the hood safety feature's to the existing building warning and fire systems are compatible and all systems operate, all verified by the fire department field inpsector & structural inspector required as a condition of final approval for use and issuance of a Letter of Completion for the Pronto Pups Kiosk location. The hood is supported to the structure above by (4)- 1/2" all-thread from the top of the hood to the support structure above and two Rawls Expansion anchors, 3" x 1/2", are inserted into the masonry fastening the hood directly to the wall structure. VERIFY THAT THERE ARE NO COMBUSTIBLE WITHIN THE RANGES SPECIFIED IN THE ER REPORT AND THAT THE EXIT SYSTEM IS NOT BLOCKED OR REDUCED. Separate electrical & mechanical permits are required. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Fee Review-notes7/1/20037/1/20037/1/2003 DONE
Permanent occupancy  1/18/2001 DONE
Perm. Occ. Cert. #8538 issued 1-18-01 to Pronto Pups at the Bank of America Center.
BLD-Final12/21/200012/22/200012/22/2000APASS
DetailsCarl Dependahl
Peter, ###-#### - call 1st so he can meet you there - Bank of America Center, okto sign at office for c/o 12/22/2000 2:52:23 PM
Permanent Occupancy 12/22/200012/22/2000 DONE
Details
FIRE-Final Inspection12/15/200012/15/200012/15/2000PPASS
DetailsRick Jackson
Scheduled by Inspector: 409 On 12/15/2000 10:15:43 AM
Issue PAID IN FULL permit  12/14/2000 DONE
Routing - FIRE11/22/2000 11/22/2000 PASS
DetailsBill Alexander
Routing - PLAN CHECK11/22/200011/22/200011/22/2000 PASS
RECEIVED APPROVAL REVIEW BY FIRE CODE ANALYST AND PUBLIC WORKS. APPROVED AS PER ATTACHED TO PLANS & ER #5148 FOR GILES RECIRCULATING GREASE HOOD. ROUTING TO PERMIT DESK.
Plan assigned to (DRS)11/20/200011/20/200011/22/2000 PASS
DetailsDan Stuart
11/22/2000 15:16:38 DRS - activity updated through activity BLDA022 from case BLD00-03478.
PLANS/APPL TAKEN TO FRONT DESK  11/22/2000 PASS
TO PERMIT DESK FOR ISSUANCE.
Inspection Record Card- Bld  11/22/2000 DONE
Print Occupancy Form  11/22/2000 DONE
Telephone call  11/22/2000 DONE
came in person permit ready
Routing - PUBLIC WORKS11/22/2000 11/22/2000 PASS
Plan Review Completed(1st rev)  11/22/2000 PASS
Routing - PLAN CHECK11/20/200011/20/200011/21/2000 PEND
Approved per the ER Report listing #5148 and fire department field inspection and approval based on required safety features being tested and approved. Routin to fire code analyst for review & comments.
Application received  11/21/2000  
Meeting  11/20/2000  
Met with Peter Peterson to review his proposed use and to determine if a building permit is required. The proposed hood unit requires connection to the existing structure; the giles hood is covered under an ICBO ER Report, and inspection and review are required by the Fire & Public Works Diviosions of PDS. A permit is required. This is also needed to tie the electrical & mechanical permits to a record.