Information based on query as of Saturday, July 4, 2026.
Permit Information
Permit NumberBLD00-03513
StatusExpired
Name GREENLEAF WHOLSALE FLORIST
Site Address 1030 W RIVER ST
Project Name 
Customer Number 
ePlanReviewNo
Description
*GREENLEAF FLORAL WAREHOUSE - WHOLESALE FLORAL* To correct and create a record of work done previous to obtaining a permit and for purpose of issuing a Certificate of Occupancy for this expanded tenant space per this permit and work done to correct code violations of the mezzanine area under BLD00-00732, issued 8/02/00 (copy attached to plans). To complete or verify completion 39 feet of 1-hour tenant separation wall, constructed in line with the existing west side tenant separation wall and extended to the north tenant wall of this space to separate a 3,330 sq. ft. portion of warehouse previously a part of West Coast Paper, 1050 W. River St. To remove a 46 foot portion of original rear tenant wall to make the 3,300 sq. ft. area a part of the Greenleaf Floral Warehouse and utilizing an existing exit door system located in the northeast corner of the new space as a second exit for the expanded occupant load & use. Add additional exit sign & verify illumination of exit way to second exit per sec. 1003.2.8 & .9, UBC. The interior of the warehouse & mezzanine were / are being remodeled under above noted permit of 8/2/00. New total area is 13,295 sq, ft. (8,826 s.f. warehouse storage, O.L. 18; 4,413 s.f. wholesale / office, O.L. 47). NOTE: This building is fully sprinkled for unlimited allowable area per records on file. PC#00-999/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection10/13/200310/13/200310/13/2003 DONE
DetailsDave Hannah
wip 10/13/2003 8:17:18 AM
BLD-Aging Inspection8/11/20038/11/20038/11/2003 DONE
DetailsCarl Dependahl
called contractor 8/11/2003 12:33:36 PM
BLD-Aging Inspection6/9/20036/9/20036/16/2003 PASS
DetailsCarl Dependahl
wip per Sundance const... 6/16/2003 1:50:51 PM
BLD-Conference4/9/20034/9/20034/9/2003ANH
DetailsCarl Dependahl
BLD-Aging Inspection12/9/200212/9/200212/9/2002 DONE
DetailsCarl Dependahl
consulted w/ DRS at office all associated work not completed at Western Paper... 12/13/2002 3:55:47 PM
Telephone call  6/28/2001 DONE
called left message that he needed to call me regarding permit. Will void out if I have not heard anything.
Issue PAID IN FULL permit  6/28/2001 DONE
Telephone call  6/25/2001 DONE
left mess that permit is ready for ryan anderson/mls
Routing - PLAN CHECK12/7/200012/7/200012/8/2000 PASS
TOOK TO DAN S. Reviewed plan note from fire dept. analyst and modified the permit to recognize the limited wholsale access to the public licensed retailers that can go to the site and walk through the facility to purchase the flowers or accessories they need. This was viewed more as a professional service such as an office rather than a full retail sales use so and occupant load factor of 100 was used as for offices instead of the nornal 30 factor. Occupant load was set at 44 wholsale area; 3 office area & 18 in storage/work areas = 13295 sq.ft. W/65 occupant load.
PLANS/APPL TAKEN TO FRONT DESK  12/8/2000 PASS
Routed to permit desk for issuance.
Print Occupancy Form  12/8/2000 DONE
Inspection Record Card- Bld  12/8/2000 DONE
Telephone call  12/8/2000 DONE
called permit ready
Plan assigned to (DRS)11/29/2000 12/8/2000 PASS
DetailsDan Stuart
12/8/2000 08:10:29 DRS - activity updated through activity BLDA022 from case BLD00-03513.
Routing - FIRE12/5/200012/5/200012/7/2000 PASS
DetailsBill Alexander
Plan Review Completed(1st rev)  12/7/2000 PASS
Routing - PLAN CHECK12/5/200012/5/200012/5/2000 PEND
Approved per notes & comments in body of permit & final of permit BLD00-00732 for mezzanine code upgrade. Routing to Fire Code Analyst
Application received  11/29/2000  
Recd Pcfee & Taken To Pln CK  11/29/2000 DONE
Plans ACCEPTED BY PLAN TECH  11/29/2000 DONE
Received Certificate of Value  11/29/2000 DONE
Fee Review-notes11/29/200011/29/2000