BLD-Final | 3/28/2001 | 3/29/2001 | 3/29/2001 | A | CANC |
Steven Webb
|
|
|
###-#### Cancel by contractor 3/29/2001 9:29:57 AM
|
BLD-Final | 3/29/2001 | 3/29/2001 | 3/29/2001 | P | PASS |
Steven Webb
|
|
|
Rick ###-#### C. Of C. # 21415 issued. 3/29/2001 12:36:30 PM
|
DOC - Permit Finaled | 3/29/2001 | 3/29/2001 | 3/29/2001 | P | PASS |
Steven Webb
|
|
|
Added by Inspector: 420 On 3/29/2001 12:36:54 PM
|
BLD-Final | 3/27/2001 | 3/28/2001 | 3/28/2001 | A | FAIL |
Steven Webb
|
|
|
Rick ###-#### C/n on site--rim joist needs insulation, pipe protection in garage. 3/28/2001 12:14:21 PM
|
BLD-Energy code compliance | 2/28/2001 | 3/1/2001 | 3/1/2001 | P | PART |
Steven Webb
|
|
|
###-####: Ok to cover--Energy report needed prior to final. 3/1/2001 1:53:41 PM
|
BLD-Framing/Rough-in | 2/28/2001 | 2/28/2001 | 2/28/2001 | P | PART |
Steven Webb
|
|
|
###-#### Ok to insulate--Need to verify bci repair above kitchen at energy. 2/28/2001 1:44:43 PM
|
BLD-Framing/Rough-in | 2/26/2001 | 2/27/2001 | 2/27/2001 | P | FAIL |
Steven Webb
|
|
|
###-####C/N posted on site--do not insulate. 2/27/2001 3:23:58 PM
|
BLD-Other | 2/19/2001 | 2/20/2001 | 2/20/2001 | A | CANC |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 02/19/2001 at 16:06:32. Contact: ###-####.
|
BLD-Wall cover | 2/20/2001 | 2/20/2001 | 2/20/2001 | A | FAIL |
Steven Webb
|
|
|
Scheduled by Inspector: 420 On 2/20/2001 10:51:13 AM
|
BLD-Framing/Rough-in | 2/20/2001 | 2/20/2001 | 2/20/2001 | P | PASS |
Steven Webb
|
|
|
###-#### ok to side. 2/20/2001 1:38:06 PM
|
BLD-Framing/Rough-in | 2/14/2001 | 2/15/2001 | 2/15/2001 | A | CANC |
Steven Webb
|
|
|
###-####: cancelled by contractor 2/15/2001 9:07:56 AM
|
BLD-Foundation | 1/23/2001 | 1/24/2001 | 1/24/2001 | P | PART |
Steven Webb
|
|
|
###-####hd not installed at time of inspection 1/24/2001 1:14:06 PM
|
BLD-Footing | 1/22/2001 | 1/23/2001 | 1/23/2001 | P | PART |
Steven Webb
|
|
|
###-#### setbacks ok, reviewed rebar and HD. 1/23/2001 3:11:49 PM
|
Issue PAID IN FULL permit | | | 1/22/2001 | | DONE |
|
|
|
|
Plan assigned to (DJO) | 1/3/2001 | 1/3/2001 | 1/19/2001 | | PASS |
Dan Overy
|
|
|
1/19/2001 07:20:58 DJO - activity updated through activity BLDA022 from case BLD00-03684.
|
Plan Reviewer's activity | | | 1/19/2001 | | DONE |
|
|
|
received two sets of revised plans on 01-17-2001. (job #99-1540). elevations incorrect. spoke with ted martinez at front counter just before lunch on 01-18-2001. i will modify plans this time only in order to permit this structure. mr. martinez advises me that he has changed designers. (robert pedersen)(dakota design)
|
Print Pending Permit.LaserJet4 | | | 1/19/2001 | | DONE |
|
|
|
|
Plan Review Report | | | 1/19/2001 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 1/19/2001 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 1/19/2001 | | DONE |
|
|
|
|
Telephone call | | | 1/19/2001 | | DONE |
|
|
|
|
Plan Reviewer's activity | | | 1/4/2001 | | PEND |
|
|
|
have spoken with riley mahaffey (structural engineer) about differences between his calculations and what is indicated on plans. will bring in his files 01-05-2001 for comparison. will advise builder.
|
Plan Reviewer's activity | | | 1/3/2001 | | PEND |
|
|
|
plans still do not comply. missing brg., holdown locations are to be verified, plans are not to scale, floor framing is not complete, nailing schedules need clarification (3 out of 4 are identical), elevations do not match floor plans, various areas of structure do not meet wall bracing and/or are not called out, all beams and headers to be indicated and seperation not met between garage/house area.
|
Plan Reviewer's activity | | | 1/3/2001 | | PEND |
|
|
|
plans rejected 12-14-2000. at this time correction list was supplied to builder. plans were accepted 12-21-2000.
|
Plans ACCEPTED BY PLAN CHECK | | | 1/3/2001 | | |
|
|
|
|
Routing - PUBLIC WORKS | 12/21/2000 | 12/21/2000 | 12/21/2000 | | PASS |
|
|
|
|
Routing - PLANNING | 12/21/2000 | 12/21/2000 | 12/21/2000 | | PASS |
|
|
|
|
Application received | | | 12/21/2000 | | |
|
|
|
|
Routing - PLAN CHECK | 12/21/2000 | 12/21/2000 | | | PEND |
|
|
|
|
Pending Assignment by DJO | 12/21/2000 | | | | PEND |
Dan Overy
|
|
|
|