Permit Information
Permit NumberBLD00-03689
StatusVoid/No Violation
Name POWER XTREME MOTOR SPORTS
Site Address 5862 W FRANKLIN RD
Project Name 
Customer Number 
ePlanReviewNo
Description
*POWER XTREME MOTOR SPORTS* To remodel a 4,869 sq.ft. tenant space for retail sales and display of products used for maintenance or accessorize motor powered vehicles. To modify and or repair motor powered vehicles W/O any flame or welding in the North portion of this tenant space. To separate the "S3" occupancy area from the retail area and the adjacent tenant spaces to the east and west with a new 1-hour occupancy separation wall; to separate the retail area from adjacent tenant spaces by construction of a 1-hour tenant demising wall. There is an existing 5.5 X 54.5 foot display shelf, a part of the original mezzanine now located in this tenant space, only accessed by a ladder to display - not accessible for any other purpose. The tenant separation wall continues from the concrete mezzanine deck to the double "T" concrete roof structure. To improve accessiblitlity to and within this tenant space and accessory areas per Appendix Chapter 11 @ 20% of the project cost - $1,500.00 - per approved plans on file. (P.C.#1067-00)/drs
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Fee Review-notes12/21/200012/21/20004/3/2002 DONE
Plan assigned to (DRS)12/26/2000 4/3/2002 VOID
DetailsDan Stuart
< $25,000
VOIDED CHANGE STATUS  4/3/2002 DONE
per dan s.
Routing - PLUMBING9/12/2001 9/17/2001 FAIL
Routing - PUBLIC WORKS9/17/2001 9/17/2001 FAIL
Public works environmental to review resubmittals when they come in. Per Louise W. kmm
Routing - PLAN CHECK9/12/20019/12/20019/12/2001 PEND
Received corrected sheet a-1 indicating location of oil separator and installation per UPC and a cover letter declaring the ventilation requirments of sec. 1202 were to be design build by mechanical contractor and electrical contractor. The minimum design capablity based on the occupancy use group declared and 15 cfm per occupant was redlined on plans for field verification and approval.
Print Pending Permit.LaserJet4  9/12/2001  
Case Summary (BLD)  9/12/2001  
Plan resubmittals received  9/12/2001 DONE
Received 3 revised sheets of A-1 and routed to Dan Stuart
Plan resubmittals received  9/12/2001  
Architect Cornel Larson provided additional sheet A-1 showing location of oil separator per UBC 311.2.3.1 to be installed per UPC. Routing plans to Public Works and Plumbing Div. for review of Oil Separator compliance.
Telephone call  9/12/2001 DONE
Called Walt Baumgartner, PW Environmental Div. to see if specific details are required for oil separator. Walt stated that detail of oil separator from plumbing div. would probalby work. I will route to plumbing for their review and comment and then to PW Environmental where wall will make copy to forward to Bench Sewer District to alert them of upcoming project. The Plumbing Div. will perform the field inspection for code compliance.
Telephone call  9/12/2001 DONE
Called Cornel Larson to let him know the oil separator was a code requirement not an option and that it needed to be shown on the plans. Also the need for direction for compliance with the ventilation requirements of section 1202 for the tenant. Cornel will contact owner and tenant and respond.
Received Certificate of Value  9/11/2001  
Received new certificate of value adding $5,500.00 for plumbing work and $4,500.00 for mechanical work, for initial values. Added $10,000.00 total to original value = $17,500.00
Routing - PLAN CHECK9/10/2001 9/11/2001 FAIL
Received resubmittals from architect. Plans failed to indicate the installation of an oil separator or trap per section 311.2.3.1 UBC and did not indicate the specifics for providing required ventilation for the tenant space. A value of 250 CFM exhaust was noted on plan for the area above the nitrous oxide but frash air requirements per section 1202 need to be met. Called Cornel Larson, architect to notify the plans are still incomplete. He said he would talk to the owner and tenant and provide response.
Plan resubmittals received  9/11/2001 DONE
Received three copies of revised sheets O, A-1, A-2, one copy of response letter. Routed to Dan Stuart. KMM
Routing - FIRE9/5/20019/5/20019/10/2001 PASS
DetailsBill Alexander
On condtion the UBC issues are resolved.
Plan resubmittals requested  9/5/2001 FAIL
Re-wrote items not being clearly answered or no answer from original review comments of March 12, 2001. Items #3, #5, # 6, #7, #8, and #13 needed further response. Copy faxed and mailed to architect.
Routing - PLAN CHECK3/16/2001 9/5/2001 FAIL
Inserted new plan sheets Ao, A-1 & A-2 into original plans. Reviewed architects cover letter in conjunction with new plan sheets submitted. Response to plan review comments incomplete. Response does not include data on ventilation for a new tenant space to meet code; floor drain system required per section 311.2.3.1 UBC was not addressed; unclear as to location of tenant occupancy separation wall between the "M" & "S3" occupancy of this tenant; new sheet A-2 is not dimension for elevations of fixture's showing compliance with accessibility; plan shows a new tunnel access to the restrooms that were not shown on the original plan submital and reports indicate done without permits or inspection. Further re-submittals are required.
Plan resubmittals received  8/28/2001  
received sheets 0, A-1, and A-2. Two copies of each. Routed to Dan Stuart. aml
Routing - FIRE3/13/2001 3/16/2001 FAIL
Need info on possible hazmat storage & use (N2O)
Plan Review Completed(1st rev)  3/16/2001 FAIL
BLD-Conference3/15/20013/15/20013/15/2001PPASS
DetailsTom Arcoraci
Report of working w/out permits. Plans still under review. notified to stop all work until permit is issued 3/15/2001 2:45:07 PM
Plan resubmittals requested  3/13/2001 FAIL
Copy of plan review corrections & clarifications required mailed and faxed to architect.
Print Pending Permit.LaserJet4  3/13/2001  
Routing - PLAN CHECK12/26/2000 3/13/2001 FAIL
Additional information and clarification required concerning use of reported hazardous products - Nitrous Oxide, and what has been done for heating and electrical before the project was discovered - all work done without permit and the tenant has occupied. Copy of corrections faxed and mailed to the architect for correction and response. Routing plans to fire code analyst for review.
Plans ACCEPTED BY PLAN TECH  12/22/2000 DONE
Plans not dimensioned. KMM
Received Certificate of Value  12/21/2000 DONE
Application received  12/21/2000  
Recd Pcfee & Taken To Pln CK     
Routing - PLAN CHECK9/19/2001