Permit Information
Permit NumberBLD01-00178
StatusFinaled
Name DENISON BROS INC
Site Address 8418 W FAIRVIEW AVE
Project NameFAIRVIEW PLAZA
Customer Number 
ePlanReviewNo
Description
To remodel a 1,526 sq.ft. office in the northwest corner of the building per approved plans on file. Work to include demolition of interior non-bearing walls; removal of ceiling tile attached to sheetrock at ceiling & recoat sheetrock W/ skim coat plaster for finish; relocate furnace & close in end of room to create new utility room; add new frame wall & sheetrock for new accessible restrooms and break room; relocate main entry door & add to ramp length to improve accessibility to the tenant space W/ handrails per code; to add new 4'-0" x 2'-0" to match existing windows in the west wall. All per approved plans, notes & attached plan review comments. VERIFY 2-HOUR AREA SEPARATION WALL (west tenant space wall??) IS IN COMPLIANCE WITH CODE. NOTE: A certificate of occupancy is required as a condition of this permit. (P.C.#0064-01)/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Fee Review-notes1/24/20011/24/20015/25/2001 DONE
FIRE-Final Inspection4/11/20014/12/20014/12/2001AFAIL
DetailsJoe Tawney
Kim ###-#### Final Fail C/N issued 4/11/2001 5:48:34 PM
BLD-Final4/11/20014/12/20014/12/2001PPASS
DetailsDave Hannah
Kim ###-#### 4/12/2001 2:30:21 PM ok for perm occ 4/12/2001 3:00:38 PM
BLD-Final4/12/20014/12/20014/12/2001PPASS
DetailsJoe Tawney
Added by Inspector: 406 On 4/12/2001 5:32:28 PM Reinsp OK for permanant occupancy
Permanent Occupancy 4/12/20014/12/2001 DONE
Details
Permanent occupancy UNPAID FEE  4/12/2001 DONE
Perm. Occ. Cert. #8628 issued 4-12-01 to Denison Brothers, Inc.
FIRE-Final Inspection4/10/20014/11/20014/11/2001AFAIL
DetailsJoe Tawney
Kim Andrew ###-#### Final Fail C/N issued 4/11/2001 12:48:08 PM
BLD-Framing/Rough-in3/7/20013/7/20013/7/2001PPASS
DetailsDave Hannah
###-####
Issue PAID IN FULL permit  2/15/2001 DONE
Routing - PLAN CHECK2/13/2001 2/14/2001 PASS
Approved as noted on plans and attached plan review.
PLANS/APPL TAKEN TO FRONT DESK  2/14/2001 PASS
To permit desk to issue
Inspection Record Card- Bld  2/14/2001 DONE
Print Occupancy Form  2/14/2001 DONE
Plan assigned to (DRS)1/25/2001 2/14/2001 PASS
DetailsDan Stuart
2/14/2001 08:12:48 DRS - activity updated through activity BLDA022 from case BLD01-00178.
Routing - FIRE2/8/2001 2/13/2001 PASS
Plan Review Completed(1st rev)  2/13/2001 PASS
Telephone call  2/13/2001 DONE
CALLED KIM ANDREWS -ARCHITECT HAS REPORTED THAT THE 2-HOUR AREA SEPARATION WALL APPEARED TO BE IN PLACE AT THE WEST SIDE OF THE DENNISON BROS REMODEL AT 8418 FAIRVIEW. I TOLD KIM THE MAINTENANCE AND UPGRADE OF THE AREA SEP WALL WOULD NEED TO BE MAINTAINED AND THAT THIS WAS LOCATED IN THE AREA OF THE FRONT ENTRY DOOR AND ALL MAY NEED TO BE UPGRADED TO MEET CODE or HAVE ARCHITECT DO PLAN ANALYSIS OF EXISTING BUILDING AND THE USE OF ALL THE 2-HOUR ANS TH 4-HOUR AREA SEPARATIONS REQUIRED AND RESUBMIT
Routing - PLAN CHECK1/26/2000 2/8/2001 PEND
Waiting for response from architect for confirmation of two hour area separation walls in relation to the key plan. Routing to fire code analyst for review.
2/9/01-RECEIVED CALL FROM ARCHITECT, BART MILLER, STATING HE HAD DRIVEN BY THE PROJECT SITE AND THE 2-HOUR AREA SEPARATION WALL APPEARS TO BE AS NOTED ON THE PLANS. THIS WILL HAVE TO BE VERIFIED BY THE INSPECTOR AND ANY MODIFICATIONS TO THE PLANS BE PROVIDED SHOWING THE 2-HOUR WALL TO REMAIN IN TACT, TO INCLUDE PARAPET or HAVE THE ARCHITECT PROVIDE A PLAN ANALYSIS TO DETERMINE WHAT AREA SEPARATION WALLS ARE REQUIRED, WHICH ARE IN PLACE AND REQUEST OTHERS NOT REQUIRED FOR A SPECIFIC CODE PURPOSE TO BE OMITTED FROM PLANS AND RECORDS SUBMITTED TO BOISE BUILDING DEPT. I WILL CALL THE CONTRACTOR TO HAVE HIM MAKE OWNER AWARE OF OPTIONS.
Routing - PUBLIC WORKS1/25/2001 1/26/2001 PASS
Pending Assignment by MYS1/25/2001 1/25/2001 DONE
DetailsMarlene Southard
Plans ACCEPTED BY PLAN TECH  1/24/2001 DONE
Plans not fully deminsioned. KMM
Received Certificate of Value  1/24/2001 DONE
Application received  1/24/2001  
Recd Pcfee & Taken To Pln CK