BLD-Aging Inspection | 5/30/2003 | 5/30/2003 | 5/30/2003 | | DONE |
Carl Dependahl
|
|
|
demo w/ larger project 5/30/2003 9:22:10 AM
|
DOC - Permit Expired | 5/30/2003 | 5/30/2003 | 5/30/2003 | A | PASS |
Carl Dependahl
|
|
|
Expired by inspector at 5/30/2003 9:22:13 AM
|
Inspection Record Card- Bld | | | 2/9/2001 | | DONE |
|
|
|
|
Telephone call | | | 2/9/2001 | | DONE |
|
|
|
called talked to annette gave dollar amount
|
Issue PAID IN FULL permit | | | 2/9/2001 | | DONE |
|
|
|
|
Plan assigned to (DRS) | 2/6/2001 | 2/6/2001 | 2/8/2001 | | PASS |
Dan Stuart
|
|
|
2/8/2001 11:42:47 DRS - activity updated through activity BLDA022 from case BLD01-00294.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 2/8/2001 | | PASS |
|
|
|
DEMO PERMIT IN PREPARATION FOR FUTURE T.I. SEPARATE PLANS AND APPLICATION REQUIRED FOR REVIEW AND APPROVAL FOR T.I.
|
Plan Review Report | | | 2/8/2001 | | |
|
|
|
COPY OF CONDITION FAXED AND MAILED TO ARCHITECT AFTER REVIEW BY THE FIRE CODE ANALYST, BILL ALEXANDER & SAM ROGERS.
|
Plan Reviewer's activity | | | 2/7/2001 | | |
|
|
|
NOTIFIED THE FIRE DEPARTMENT THAT AN APPLICATION FOR DEMOLITION OF A MAJOR PORTION OF THE 6TH FLOOR HAS BEEN APPLIED FOR. THE REMODEL OF THE 6TH FLOOR FOR OFFICE USE IN 1992 TRIGGERED THE REQUIREMENTS FOR UPGRADE OF THE BUILDING AS AN EXISTING HIGH RISE FACILITY AND THE SPECIFIC REQUIREMENTS WERE ESTABLISHED BY AN 'APPEALS BOARD HEARING'. THERE APPEAR TO BE DIFFERENT FEELINGS WITHIN THE FIRE DEPARTMENT AT THIS TIME IN REGARDS TO THE OMMISSION OF SPRINKLER SYSTEM IN ANY PART OF THE BUILDING AND THIS WILL NEED TO BE ADDRESSED WITH THE FIRE DEPARTMENT AS PART OF THE PLAN SUBMITTAL FOR THE REMODEL OF THIS 6TH FLOOR AREA.
|
Telephone call | | | 2/7/2001 | | DONE |
|
|
|
CALLED BOB SMITH, ARCHITECT FOR QWEST TO INFORM HIM THAT THE REMODEL OF THIS 6TH FLOOR FROM THE OFFICE USE APPROVED UNDER THE 1992 LETTER OF AGREEMENT ON FILE MAY REQUIRE THE NEW PROPOSED TELEPHONE EQUIPMENT EXCHANGE USE TO BE FULLY SPRINKLED RATHER THAN ALLOWING THE CONDITIONS OF SECTION 904.4 (3804, 1991 UBC) TO APPLY. THIS WILL BE DETERMINED THROUGH AGREEMENT AND PROPOSALS WITH THE FIRE & BUILDING DEPARTMENTS AT TIME OF PLAN SUBMITTALS. THE FEELING AT THIS TIME IS THAT THE SPRINKLER SYSTEM WILL HAVE TO BE INSTALLED UNDER FIRE FLOW REQUIREMENTS OF APPENDIX CHAPTER III-A 1997 UFC.
|
Plan Reviewer's activity | | | 2/7/2001 | | |
|
|
|
FAXED COPIY OF ORIGINAL LETTER OF AGREEMENT SIGNED BY ALL PARTIES ORIGINALLY INVOLVED AND THE SPECIFIC AGREEMENT CONDITIONS ESTABLISHED TO BOB SMITH AT HIS REQUEST.
|
Application received | | | 2/6/2001 | | |
|
|
|
|