Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberBLD01-00710
StatusFinaled
Name BUDDIES PUB
Site Address 8654 W OVERLAND RD
Project NameOVERLAND MARKET
Customer Number 
ePlanReviewNo
Description
(BUDDIES PUB)(OVERLAND MARKET) To construct a 2,440 sq.ft. bar within a tenant space in a shopping center per approved plans on file. Original builidng constructed in ada county. Work to include, Construction of two accessible restrooms, installation of suspended ceiling system, installation of a walk-in cooler, Construction of bar and related miscelaneous interior finishes. NOTE: This building is fully fire sprinklered for area increase. Any alterations or modifications to the fire sprinkler system shall be per NFPA #13 as regulated by the fire department. (P.C.#0243-01)*RmH*
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Permanent occupancy  10/11/2001 DONE
Perm. Occ. Cert. #8862 issued 10-11-01 to Buddies Pub in the Overland Market.
Permanent Occupancy 10/9/200110/9/2001 DONE
Details
BLD-Final10/8/200110/9/200110/9/2001APASS
DetailsRuss Owen
jeff ###-#### . ok perm occupancy. 10/9/2001 10:04:53 AM
BLD-Final9/26/20019/27/20019/27/2001ANR
DetailsRuss Owen
Let me know if everything is aok - Thanks! Still need mirror lowered in rest room. 9/27/2001 11:39:31 AM
BLD-Final9/7/20019/7/20019/7/2001PPASS
DetailsJoe Tawney
Added by Inspector: 406 On 9/7/2001 1:59:54 PM Reinsp Ok for permanant occupancy
Fee Review-notes3/21/20013/21/20019/7/2001 DONE
FIRE-Final Inspection7/26/20017/27/20017/27/2001APASS
DetailsJoe Tawney
Reinsp OK for temp occ. Duct detectors connected to alarm system 7/27/2001 10:18:42 AM
BLD-Final7/26/20017/27/20017/27/2001APART
DetailsRuss Owen
Scheduled by a contractor via Hello! on 07/26/2001 at 15:20:34. Contact: ###-####.ok temp oc needs all req signatures for perm oc and c/n rest room mirror. 7/27/2001 11:46:00 AM
Temporary occupancy  7/27/2001 DONE
Temp. Occ. Cert. #4568 issued 7-27-01 to Buddies Pub.
FIRE-Final Inspection7/23/20017/23/20017/23/2001PFAIL
DetailsJoe Tawney
###-#### Final Fail C/N issued 7/23/2001 6:23:53 PM
BLD-Other7/17/20017/18/20017/18/2001APASS
DetailsTom Arcoraci
Scheduled by a contractor via Hello! on 07/17/2001 at 12:23:08. Contact: ###-####. grid ok 7/17/2001 10:50:15 PM
BLD-Framing/Rough-in7/6/20017/6/20017/6/2001PFAIL
DetailsRuss Owen
Jeff Alexander ###-#### grid ceiling. 7/6/2001 3:33:47 PM
FIRE-Conference6/11/20016/12/20016/12/2001APASS
DetailsJoe Tawney
Conf with Jeff on fire life/safety issues 6/12/2001 1:39:13 PM
BLD-Framing/Rough-in6/11/20016/11/20016/11/2001PPASS
DetailsDave Hannah
later pm jeff ###-####
BLD-Conference6/1/20016/1/20016/1/2001PPART
DetailsRuss Owen
Scheduled by a contractor via Hello! on 06/01/2001 at 10:40:03. Contact: ###-####. doing own work had questions. 1/1/2002 2:19:27 PM
Issue PAID IN FULL permit  5/2/2001 DONE
PLANS/APPL TAKEN TO FRONT DESK  4/26/2001 PASS
DetailsRon Hill
Inspection Record Card- Bld  4/26/2001 DONE
Print Occupancy Form  4/26/2001 DONE
Telephone call  4/26/2001 DONE
left mess that permit is ready
Plan assigned to (R_H)3/29/2001 4/26/2001 PASS
Details
4/26/2001 08:18:12 RMH - activity updated through activity BLDA022 from case BLD01-00710.
Routing - PLUMBING4/25/20014/25/20014/25/2001 PASS
per resubmitted plans dated 4/24/01 and 97 upc
Routing - PLUMBING4/24/20014/24/20014/24/2001 FAIL
you cant wet vent a urinak on to a floor drain, vent the mens restroom fd, 1 1/4" min. water supply will be required. You show 3/4". Your showing all the cold water branch lines connecting to the main building water line, all piping must be routed thru the 1 1/4" min. shut off valve for this unit. a 3" clean out will be required at the bar area. additional cross connection may be required.
Routing - PLAN CHECK4/24/2001 4/24/2001  
DetailsRon Hill
Recieved resubmitted plan sheets for plumbing routed back to plumbing for reveiw. On 3-24-01 at 1:30
Plan resubmittals received  4/24/2001 DONE
Received two sets of page 3 for plan resubmittals, from Mike Fairchild, Architect.frowarded same to Ron Hill. 4/24/01 DAR
Routing - PLAN CHECK4/18/2001 4/24/2001  
Plan Reviewer's activity  4/18/2001 PEND
Received resubmitted plumbing sheets and plans back from fire departments review. Routed to plumbing for review of resubmitted plumbing sheets. Permit pending plumbing departments review and approval.
Routing - FIRE4/13/2001 4/18/2001 PASS
Plan resubmittals received  4/17/2001 DONE
Received plumbing plan resubmittals, forwarded same to Ron Hill. 4/17/01 DAR
Plan Reviewer's activity  4/13/2001 PEND
DetailsRon Hill
Plans not approved by pumbing department, No corrections required from building plan review, routing to fire for review. Permit is pending Plumbing approval, and fire department approvals.
Routing - PLAN CHECK4/4/2001 4/12/2001 PEND
DetailsRon Hill
permit pending, plumbing approvals and fire department review and approval
Routing - PLUMBING4/2/2001 4/4/2001 FAIL
provide a vent for each fixture, provide indirect waste receptors for bar/food prep area, provide a valve controlling all outlets in this tenant space, thermol expantion protection may be required, provide a fixture schedule for all fixtures and equipment, additional cross connection protection may be required.
Routing - PUBLIC WORKS3/29/2001 4/2/2001 PASS
Print Pending Permit.LaserJet4  3/29/2001  
Plans ACCEPTED BY PLAN TECH  3/22/2001 DONE
Will fax signed arch/eng. record form.
Received Certificate of Value  3/21/2001 DONE
Recd Pcfee & Taken To Pln CK  3/21/2001 DONE
Application received  3/21/2001  
Routing - PLAN CHECK4/26/2001